-
Notifications
You must be signed in to change notification settings - Fork 0
/
Copy pathRose.rules
87 lines (86 loc) · 2.64 KB
/
Rose.rules
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
(rules PCB Rose
(snap_angle
fortyfive_degree
)
(autoroute_settings
(fanout off)
(autoroute on)
(postroute on)
(vias on)
(via_costs 50)
(plane_via_costs 5)
(start_ripup_costs 100)
(start_pass_no 10027)
(layer_rule F.Cu
(active on)
(preferred_direction horizontal)
(preferred_direction_trace_costs 1.0)
(against_preferred_direction_trace_costs 3.9)
)
(layer_rule B.Cu
(active on)
(preferred_direction vertical)
(preferred_direction_trace_costs 1.0)
(against_preferred_direction_trace_costs 1.3)
)
)
(rule
(width 250.0)
(clear 200.2)
(clear 125.0 (type smd_to_turn_gap))
(clear 50.0 (type smd_smd))
)
(padstack "Via[0-1]_600:400_um"
(shape
(circle F.Cu 600.0 0.0 0.0)
)
(shape
(circle B.Cu 600.0 0.0 0.0)
)
(attach off)
)
(via
"Via[0-1]_600:400_um" "Via[0-1]_600:400_um" default
)
(via
"Via[0-1]_600:400_um-kicad_default" "Via[0-1]_600:400_um" "kicad_default"
)
(via_rule
default "Via[0-1]_600:400_um"
)
(via_rule
"kicad_default" "Via[0-1]_600:400_um-kicad_default"
)
(class "kicad_default"
"Net-(C1-Pad2)" "Net-(C2-Pad2)" VCC "Net-(C6-Pad2)" /ROW0 "Net-(D1-Pad2)" "Net-(D2-Pad2)" "Net-(D3-Pad2)"
"Net-(D4-Pad2)" "Net-(D5-Pad2)" "Net-(D6-Pad2)" "Net-(D7-Pad2)" "Net-(D8-Pad2)" "Net-(D9-Pad2)" "Net-(D10-Pad2)" "Net-(D11-Pad2)"
"Net-(D12-Pad2)" /ROW1 "Net-(D13-Pad2)" "Net-(D14-Pad2)" "Net-(D15-Pad2)" "Net-(D16-Pad2)" "Net-(D17-Pad2)" "Net-(D18-Pad2)"
"Net-(D19-Pad2)" "Net-(D20-Pad2)" "Net-(D21-Pad2)" "Net-(D22-Pad2)" "Net-(D23-Pad2)" "Net-(D24-Pad2)" "Net-(D25-Pad2)" "Net-(D26-Pad2)"
"Net-(D27-Pad2)" "Net-(D28-Pad2)" "Net-(D29-Pad2)" "Net-(D30-Pad2)" "Net-(D31-Pad2)" "Net-(D32-Pad2)" "Net-(D33-Pad2)" "Net-(D34-Pad2)"
"Net-(D35-Pad2)" "Net-(D36-Pad2)" "Net-(D37-Pad2)" "Net-(D38-Pad2)" "Net-(D39-Pad2)" "Net-(D40-Pad2)" "Net-(D41-Pad2)" "Net-(D42-Pad2)"
"Net-(D43-Pad2)" "/D-" /D+ "Net-(LED1-Pad2)" /ws2812 "Net-(LED5-Pad2)" /COL0 "Net-(MX1-Pad3)"
"/LED_C" /COL1 /COL2 /COL3 /COL4 /COL5 /COL6 /COL7
/COL8 /COL9 /COL10 /COL11 "Net-(Q1-Pad1)" "Net-(R44-Pad2)" "Net-(R45-Pad2)" "Net-(R47-Pad2)"
"Net-(LED2-Pad2)" "Net-(LED3-Pad2)" "Net-(LED4-Pad2)" "Net-(LED6-Pad2)" "Net-(LED7-Pad2)" /MOSI /MISO /RST
/ROW2 /ROW3 /SCK
(clearance_class "kicad_default")
(via_rule kicad_default)
(rule
(width 250.0)
)
(circuit
(use_layer F.Cu B.Cu)
)
)
(class class1
GND
(clearance_class "kicad_default")
(via_rule kicad_default)
(rule
(width 250.0)
)
(circuit
(use_layer F.Cu B.Cu)
)
)
)