{ "Boiler Buderus GBx72/Trendline/Cerapur/Greenstar Si (DeviceID:0x08, ProductID:123, Version:07.00)": { "force heating off (heatingoff)": "off", "heating active (heatingactive)": "off", "tapwater active (tapwateractive)": "off", "selected flow temperature (selflowtemp)": 5, "heating pump modulation (heatingpumpmod)": 0, "outside temperature (outdoortemp)": 22, "current flow temperature (curflowtemp)": 52.8, "mixing switch temperature (switchtemp)": 62.3, "gas (burngas)": "off", "gas stage 2 (burngas2)": "off", "flame current (flamecurr)": 0, "fan (fanwork)": "off", "ignition (ignwork)": "off", "oil preheating (oilpreheat)": "off", "burner min power (burnminpower)": 0, "burner max power (burnmaxpower)": 100, "burner min period (burnminperiod)": 10, "hysteresis on temperature (boilhyston)": -6, "hysteresis off temperature (boilhystoff)": 6, "hysteresis stage 2 on temperature (boil2hyston)": 0, "hysteresis stage 2 off temperature (boil2hystoff)": 0, "heatingcurve on (curveon)": "off", "heatingcurve base (curvebase)": 20, "heatingcurve end (curveend)": 90, "summer temperature (summertemp)": 16, "nofrost mode (nofrostmode)": "off", "nofrost temperature (nofrosttemp)": 5, "heating activated (heatingactivated)": "on", "heating temperature (heatingtemp)": 40, "heating pump (heatingpump)": "off", "boiler pump max power (pumpmodmax)": 100, "boiler pump min power (pumpmodmin)": 10, "boiler pump mode (pumpmode)": "proportional", "pump delay (pumpdelay)": 3, "set flow temperature (setflowtemp)": 0, "burner set power (setburnpow)": 0, "burner selected max power (selburnpow)": 0, "burner current power (curburnpow)": 0, "burner starts (burnstarts)": 18095, "total burner operating time (burnworkmin)": "151 days 18 hours 35 minutes", "burner stage 2 operating time (burn2workmin)": "0 days 0 hours 0 minutes", "total heat operating time (heatworkmin)": "94 days 11 hours 1 minutes", "burner starts heating (heatstarts)": 14483, "total UBA operating time (ubauptime)": "1350 days 1 hours 3 minutes", "last error code (lastcode)": "6A(227) 14.09.2023 10:30 (0 min)", "service code (servicecode)": "0H", "service code number (servicecodenumber)": 203, "maintenance message (maintenancemessage)": "H00", "maintenance scheduled (maintenance)": "off", "time to next maintenance (maintenancetime)": 6000, "next maintenance date (maintenancedate)": "01.01.2009", "dhw set temperature (wwsettemp)": 63, "dhw selected temperature (wwseltemp)": 70, "dhw type (wwtype)": "buffer", "dhw comfort (wwcomfort)": "hot", "dhw flow temperature offset (wwflowtempoffset)": 20, "dhw max power (wwmaxpower)": 100, "dhw circulation pump available (wwcircpump)": "on", "dhw charging type (wwchargetype)": "chargepump", "dhw hysteresis on temperature (wwhyston)": -5, "dhw hysteresis off temperature (wwhystoff)": 0, "dhw disinfection temperature (wwdisinfectiontemp)": 70, "dhw circulation pump mode (wwcircmode)": "1x3min", "dhw circulation active (wwcirc)": "off", "dhw current intern temperature (wwcurtemp)": 66.6, "dhw current extern temperature (wwcurtemp2)": 66.6, "dhw current tap water flow (wwcurflow)": 0, "dhw storage extern temperature (wwstoragetemp2)": 66.5, "dhw activated (wwactivated)": "on", "dhw one time charging (wwonetime)": "off", "dhw disinfecting (wwdisinfecting)": "off", "dhw charging (wwcharging)": "off", "dhw recharging (wwrecharging)": "off", "dhw temperature ok (wwtempok)": "on", "dhw active (wwactive)": "off", "dhw 3-way valve active (ww3wayvalve)": "off", "dhw set pump power (wwsetpumppower)": 0, "dhw starts (wwstarts)": 3612, "dhw active time (wwworkm)": "57 days 7 hours 34 minutes", "nominal Power (nompower)": 20, "total energy (nrgtotal)": 9647.08, "energy heating (nrgheat)": 793.71, "dhw energy (nrgww)": 8853.37 }, "Thermostat RC300/RC310/Moduline 3000/1010H/CW400/Sense II/HPC410 (DeviceID:0x10, ProductID:158, Version:74.01)": { "date/time (datetime)": "16.08.2024 08:32", "internal temperature offset (intoffset)": 0, "floor drying (floordry)": "off", "damped outdoor temperature (dampedoutdoortemp)": 21, "floor drying temperature (floordrytemp)": 0, "building type (building)": "light", "minimal external temperature (minexttemp)": -12, "damping outdoor temperature (damping)": "on", "dhw set temperature (wwsettemp)": 60, "dhw mode (wwmode)": "own prog", "dhw set low temperature (wwsettemplow)": 45, "dhw circulation pump mode (wwcircmode)": "own prog", "dhw charge duration (wwchargeduration)": 45, "dhw charge (wwcharge)": "off", "dhw circuit 1 extra (wwextra1)": 0, "dhw disinfecting (wwdisinfecting)": "off", "dhw disinfection day (wwdisinfectday)": "tu", "dhw disinfection time (wwdisinfecttime)": 120, "hc1 selected room temperature (seltemp)": 22, "hc1 mqtt discovery current room temperature (haclimate)": "selTemp", "hc1 mode (mode)": "auto", "hc1 mode type (modetype)": "comfort", "hc1 eco temperature (ecotemp)": 20.5, "hc1 manual temperature (manualtemp)": 22, "hc1 comfort temperature (comforttemp)": 22, "hc1 summer temperature (summertemp)": 17, "hc1 design temperature (designtemp)": 45, "hc1 offset temperature (offsettemp)": 0, "hc1 min flow temperature (minflowtemp)": 25, "hc1 max flow temperature (maxflowtemp)": 48, "hc1 room influence (roominfluence)": 0, "hc1 room influence factor (roominflfactor)": 4, "hc1 current room influence (curroominfl)": 0, "hc1 nofrost mode (nofrostmode)": "outdoor", "hc1 nofrost temperature (nofrosttemp)": 5, "hc1 target flow temperature (targetflowtemp)": 0, "hc1 heating type (heatingtype)": "floor", "hc1 set summer mode (summersetmode)": "summer", "hc1 summer mode (summermode)": "summer", "hc1 control mode (controlmode)": "weather compensated", "hc1 program (program)": "prog 1", "hc1 temporary set temperature automode (tempautotemp)": -1, "hc1 temporary set temperature from remote (remoteseltemp)": 0, "hc1 fast heatup (fastheatup)": 0, "hc1 switch-on optimization (switchonoptimization)": "off", "hc1 reduce mode (reducemode)": "reduce", "hc1 no reduce below temperature (noreducetemp)": -31, "hc1 off/reduce switch temperature (reducetemp)": 0, "hc1 cooling (coolingon)": "off", "hc1 HP Mode (hpmode)": "heating", "hc1 control device (control)": "RC310" }, "Mixer Module MM100 (DeviceID:0x20, ProductID:160, Version:24.05)": { "hc1 flow temperature (TC1) (flowtemphc)": 49.8, "hc1 mixing valve actuator (VC1) (valvestatus)": 0, "hc1 setpoint flow temperature (flowsettemp)": 0, "hc1 pump status (PC1) (pumpstatus)": "off" }, "Solar Module SM100/MS100 (DeviceID:0x2A, ProductID:163, Version:27.05)": { "dhw temperature 1(TS17) (wwtemp1)": 50.2, "dhw temperature 3 (TS21) (wwtemp3)": 64.8, "dhw temperature 7 (wwtemp7)": 55, "dhw pump (wwpump)": "off", "dhw maximum temperature (wwmaxtemp)": 60, "dhw selected temperature (wwseltemp)": 55, "dhw reduced temperature (wwredtemp)": 50, "dhw daily temperature (wwdailytemp)": 60, "dhw disinfection temperature (wwdisinfectiontemp)": 70, "dhw circulation active (wwcirc)": "off", "dhw circulation pump mode (wwcircmode)": "on", "dhw keep warm (wwkeepwarm)": "off", "dhw status 2 (wwstatus2)": "no heat", "dhw pump modulation (wwpumpmod)": 0, "dhw flow rate (wwflow)": 0 }, "Solar Module SM200/MS200 (DeviceID:0x30, ProductID:164, Version:25.06)": { "collector temperature (TS1) (collectortemp)": 34.1, "cylinder bottom temperature (TS2) (cylbottomtemp)": 56.7, "pump (PS1) (solarpump)": "off", "pump working time (pumpworktime)": "189 days 18 hours 55 minutes", "maximum cylinder temperature (cylmaxtemp)": 85, "collector shutdown (collectorshutdown)": "off", "cyl heated (cylheated)": "off", "pump modulation (PS1) (solarpumpmod)": 0, "minimum pump modulation (pumpminmod)": 30, "pump turn on difference (turnondiff)": 10, "pump turn off difference (turnoffdiff)": 5, "cylinder middle temperature (TS3) (cylmiddletemp)": 62, "return temperature heat assistance (TS4) (retheatassist)": 54.5, "heat assistance valve (M1) (heatassistvalve)": "off", "heat assistance valve power (M1) (heatassistpower)": 0, "pump 2 (PS4) (solarpump2)": "off", "pump 2 modulation (PS4) (solarpump2mod)": 0, "cylinder pump modulation (PS5) (cylpumpmod)": 0, "valve status (valvestatus)": "off", "valve status VS1 (vs1status)": "on", "maximum collector temperature (collectormaxtemp)": 120, "minimum collector temperature (collectormintemp)": 20, "energy last hour (energylasthour)": 0, "total energy today (energytoday)": 0, "total energy (energytotal)": 13744.1, "pump 2 working time (pump2worktime)": "0 days 0 hours 0 minutes", "differential control working time (m1worktime)": "0 days 0 hours 0 minutes", "heattransfer system (heattransfersystem)": "off", "external cylinder (externalcyl)": "off", "thermal disinfection (thermaldisinfect)": "off", "heatmetering (heatmetering)": "off", "activated (activated)": "on", "pump mode (solarpumpmode)": "pwm", "pump kick (pumpkick)": "off", "plain water mode (plainwatermode)": "off", "doublematchflow (doublematchflow)": "off", "pump 2 turn on difference (turnondiff2)": 10, "pump kick 2 (pump2kick)": "off", "climate zone (climatezone)": 95, "collector 1 area (collector1area)": 10.2, "cylinder priority (cylpriority)": "cyl 1", "heat counter impulses (heatcnt)": 0 }, "Controller Module BC25 (DeviceID:0x09, ProductID:125, Version:03.05)": {}, "Custom Entities": {}, "Analog Sensors": {}, "Temperature Sensors": {} }