Skip to content

Latest commit

 

History

History
53 lines (39 loc) · 1.7 KB

analog.rst

File metadata and controls

53 lines (39 loc) · 1.7 KB

analog

analog(name)
  [.with_precision(precision)]
  [.with_threshold(threshold_value, "high_word", "low_word")]
  [.with_filter(filter_function)]
  ;

Create a new analog sensor. By default it reports all value changes. An analog value is between 0 an 1023. If precision is > 1, report only changes with a delta/difference to the last reported value with at least precision. Setting threshold to a value from 0 to 1023 triggers sending high_word, when the sensor reads this threshold value or a higher value, and low_word when reading a lower value.

A filter_function can be specified to modify and pre-process values right after they have been read from the analog port to for example buffer some values and build an average, median, or even implement a (fast) fourier transformation.

Parameters

  • name: the name it can be addressed via MQTT in the network. Inside the code it can be addressed via IN(name).
  • precision: report only changes with at least this delta.
  • threshold: turn into digital sensor, sending high_word when threshold is reached and low_word if not.
  • filter_function: specify a preprocessor for measured values (see filter).

Example

Assuming nodename is basement/water-sensor01.

analog(water).with_precision(10).with_threshold(100, "wet", "dry");