Notifications
You must be signed in to change notification settings - Fork 293
Inch and Millimeter Units Mode
This page discusses G20/G21 units mode selection and related topics. It explains how things work and what to expect.
###G20 / G21 - Set Units Mode Basically:
- G20 will cause all gcode and settings from this point on to be interpreted in inches
- G21 will cause all gcode and settings from this point on to be interpreted in millimeters
The current units mode setting is referred to as the 'prevailing units mode'. The prevailing units mode will remain in effect until:
- It is changed by another G20 or G21 command
- An M2 or M30 Program END is hit. At this point it will revert to the Default units ($gun)
Note that a Program STOP (M0, M1) does not change the units mode.
The units mode affects all the following:
- Gcode execution, including:
- XYZ axis positions in gcode programs (ABC are in degrees regardless of unit mode).
- Feed rate in gcode programs (F words)
- Coordinate offsets - whether entered via G10 or $g54 or similar
- Status reports returned by gcode execution (See Status Reports section below)
- Velocity and feed rate reporting
- Position reporting (except mpos)
- Configuration settings, including:
- Almost all axis settings
- Travel per revolution motor setting {1tr:...}
- Junction acceleration {ja:...}
- Chordal tolerance {ct:...}
###JSON versus Text Mode The units mode should be the same regardless of whether the system is operating in JSON mode or text mode.
###$GUN, {gun:_} - Set Default Units Mode The GUN setting sets the default (starting) units mode on power-on or reset. Gun does not change the units mode on the board if it is changed. It only affects the mode during power on or reset.
###Status Reports Status reports return all values in the prevailing units mode with the following exceptions.
-
mpox ... mpoc - Machine positions The machine positions values (mpox, mpoy ...mpoc) are always in millimeter units and always in the machine absolute coordinate system (G53). This is so that hosts and UI's can always have a stable position reference for display generation regardless of the G2/G21 setting or the coordinate system and offsets selected (G54-G59, G92).
-
ofsx ... ofsc - Work offsets are also always returned in mm mode for the same reasons.
In order to interpret the Mpos values back to work coordinates (say for DRO display), the status reports should also return the units (unit) and offsets (ofsx, ofsy ... ofsc) for the axes being monitored.
Getting Started Pages
- Home
- What is TinyG?
- Getting Started
- Connecting TinyG
- Configuring TinyG
- Sending Gcode Files
- Flashing TinyG
- Chilipeppr
Reference Pages
- TinyG Help Page
- TinyG Tuning
- TinyG Command Line
- TinyG JSON
- Gcode Support
- Homing and Limits
- Inch and MM Units
- Alarms and Exceptions
- Coordinate Systems
- Status Codes
- Status Reports
- Power Management
- Feedhold and Resume
- Licensing
- TinyG v8 Data Sheet
Discussion Topics
- Test-Drive-TinyG
- Jerk Controlled Motion
- Gcode Parsing
- Shapeoko Setup
- OX CNC TinyG Guide
- Creating Gcode Files
- Milling With Noisy Spindles
- Stepper Motors and Power Supplies
- Text Wrappers and Transaction IDs
- Using External Drivers
- TinyG Projects
Chilipeppr
- Chilipeppr
- Chilipeppr Advanced Usage
- Chilipeppr Archive and Restore Parameters
- ChiliPeppr PCB Auto Level
- Automatic Z Homing When Milling PCBs
Troubleshooting
Developer Pages