substitutions:
name: hewalex-g422-modbus
device_description: "Monitor and control a Hewalex G422 System via RS485"
external_components_source: github://smaksimowicz/esphome-hewalex-g422@main
tx_pin: GPIO17
rx_pin: GPIO16
rx_timeout: 150ms
esphome:
name: ${name}
comment: ${device_description}
project:
name: "smaksimowicz.esphome-hewalex-g422"
version: 1.0.0
esp8266:
board: d1_mini
external_components:
- source: ${external_components_source}
refresh: 0s
wifi:
ssid: !secret wifi_ssid
password: !secret wifi_password
ota:
logger:
level: NONE
# If you use Home Assistant please remove this `mqtt` section and uncomment the `api` component!
# The native API has many advantages over MQTT: https://esphome.io/components/api.html#advantages-over-mqtt
mqtt:
broker: !secret mqtt_host
username: !secret mqtt_username
password: !secret mqtt_password
id: mqtt_client
# api:
uart:
- id: uart_0
baud_rate: 115200
tx_pin: ${tx_pin}
rx_pin: ${rx_pin}
hewalex_g422:
- id: g422_0
update_interval: 1s
rx_timeout: ${rx_timeout}
sensor:
- platform: hewalex_g422
hewalex_g422_id: g422_0
temperature_1:
name: "T1 (Collectors temp)"
temperature_2:
name: "T2 (Tank bottom temp)"
temperature_3:
name: "T3 (Air separator temp)"
temperature_4:
name: "T4 (Tank top temp)"
temperature_5:
name: "T5 (Boiler outlet temp)"
temperature_6:
name: "T6 ()"
collector_power:
name: "Collector Power (W)"
consumption_w:
name: "Consumption (W)"
collector_active:
name: "Collector Active (1/0)"
flow_rate:
name: "Flow Rate (l/min)"
unit_of_measurement: "l/min"
collector_pump_on:
name: "Collector Pump (P) ON (1/0)"
boiler_pump_on:
name: "Boiler Pump (K) ON (1/0)"
circulation_pump_on:
name: "Circulation Pump (C) ON (1/0)"
collector_pump_speed:
name: "Collector Pump Speed (0-15)"
total_energy_kwh:
name: "Collector Total Energy (kWh)"
filters:
lambda: return 5079138.0 ;
switch:
- platform: gpio
pin:
number: GPIO32
inverted: false
name: "Circulation pump switch"