This describes the Z-Wave device ZME_FT, manufactured by Z-Wave.Me with the thing type UID of zwaveme_zmeft_00_000
.
The device is in the category of HVAC, defining Air condition devices, Fans.
The ZME_FT supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
Underfloor heating thermostat allows you to control the heating mat or other load in the on / off mode to maintain the set temperature. The device can operate in two control circuits:
-
autonomous maintenance of the set floor temperature
-
controlled by Z-Wave to maintain the set room temperature (requires an external Z-Wave thermostat,installed indoors)
The kit includes a temperature sensor. In all modes, the thermostat protects the floor structure from overheating, turning off load when the temperature threshold is reached
press and hold the central round mode change button for 5 seconds
press and hold the central round mode change button for 5 seconds
The following table summarises the channels available for the ZME_FT -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Sensor (temperature) | sensor_temperature | sensor_temperature | Temperature | Number:Temperature |
Thermostat mode | thermostat_mode | thermostat_mode | Temperature | Number |
Setpoint (heating) | thermostat_setpoint | thermostat_setpoint | Heating | Number:Temperature |
Setpoint (furnace) | thermostat_setpoint | thermostat_setpoint | Heating | Number:Temperature |
Indicates the current temperature.
The sensor_temperature
channel is of type sensor_temperature
and supports the Number:Temperature
item and is in the Temperature
category.
Sets the thermostat.
The thermostat_mode
channel is of type thermostat_mode
and supports the Number
item and is in the Temperature
category.
The following state translation is provided for this channel to the Number
item type -:
Value | Label |
---|---|
0 | Off |
1 | Heat |
2 | Cool |
3 | Auto |
4 | Aux Heat |
5 | Resume |
6 | Fan Only |
7 | Furnace |
8 | Dry Air |
9 | Moist Air |
10 | Auto Changeover |
11 | Heat Economy |
12 | Cool Economy |
13 | Away |
Sets the thermostat setpoint.
The thermostat_setpoint
channel is of type thermostat_setpoint
and supports the Number:Temperature
item and is in the Heating
category.
Sets the thermostat setpoint.
The thermostat_setpoint
channel is of type thermostat_setpoint
and supports the Number:Temperature
item and is in the Heating
category.
The following table provides a summary of the 7 configuration parameters available in the ZME_FT. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Boost Dry mode duration | |
2 | Button mode | |
3 | Basic mode | |
4 | Temperature control interval | |
5 | Maximum allowed temperature deviation | |
6 | Maximal allowed temperature | Maximal allowed temperature |
10 | Typical click timeout | Typical time used to differenciate click from hold |
Values in the range 0 to 1800 may be set.
The manufacturer defined default value is 1800
.
This parameter has the configuration ID config_1_2
and is of type INTEGER
.
The following option values may be configured -:
Value | Description |
---|---|
0 | Toggle Normal Heating / Off |
1 | Toggle Normal Heating / Energy Save |
2 | Toggle Boost Dry |
The manufacturer defined default value is 0
(Toggle Normal Heating / Off).
This parameter has the configuration ID config_2_1
and is of type INTEGER
.
The following option values may be configured -:
Value | Description |
---|---|
0 | Toggle Normal Heating / Off |
1 | Toggle Normal Heating / Energy Save |
2 | Toggle Boost Dry |
3 | Set Normal Heating set point temperature |
4 | Switch on/off relay directly |
The manufacturer defined default value is 0
(Toggle Normal Heating / Off).
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
Values in the range 1 to 60 may be set.
The manufacturer defined default value is 18
.
This parameter has the configuration ID config_4_1
and is of type INTEGER
.
Values in the range 1 to 60 may be set.
The manufacturer defined default value is 30
.
This parameter has the configuration ID config_5_1
and is of type INTEGER
.
Maximal allowed temperature In all modes the thermostat will switch off heating until temperature drops below this limit. For wooden and laminate floor maximal allowed temperature is 27 degree. For tile and concrete floor maximal allowed temperature value is 45 degree. Values in the range 20 to 55 may be set.
The manufacturer defined default value is 27
.
This parameter has the configuration ID config_6_1
and is of type INTEGER
.
Typical time used to differenciate click from hold
Values in the range 1 to 100 may be set.
The manufacturer defined default value is 50
.
This parameter has the configuration ID config_10_1
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The ZME_FT supports 1 association group.
Unsolicited notifications about thermostat mode and setpoint temperature changes
Association group 1 supports 10 nodes.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SENSOR_MULTILEVEL_V4 | |
COMMAND_CLASS_THERMOSTAT_MODE_V1 | |
COMMAND_CLASS_THERMOSTAT_SETPOINT_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_PROTECTION_V1 | |
COMMAND_CLASS_NODE_NAMING_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V1 |