This describes the Z-Wave device ZEN26, manufactured by Zooz with the thing type UID of zooz_zen26v2_02_000
.
This version of the device is limited to firmware versions above 2.0
The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.
The ZEN26 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
Manual or Z-Wave on/off control with instant status updates
Simple Direct 3-Way: connect with existing on/off switches in 3-way, 4-way, and 5-way set-ups, no add-on needed (neutral wire required)
Remembers and restores on/off status after power failure
LED indicator signals inclusion, exclusion, reset, and setting changes
Built-in Z-Wave Plus signal repeater to extend network range
Works with LED, CFL, and incandescent bulbs
S2 security protocol and the latest 500 Z-Wave chip for faster and safer wireless communication
Supported by most Z-Wave controllers
TAP Upper paddle 3-5 TIMES QUICKLY
The LED indicator will blink to signal communication and remain on for 2 seconds to confirm inclusion
Tap the lower paddle on the switch 3 times quickly
To complete factory reset process manually, tap-tap-tap’n’hold the upper paddle for at least 10 seconds. The LED indicator will flash to confirm successful reset. NOTE: All previously recorded activity and custom settings will be erased from the device’s memory.
**Upper Paddle: **
1 x tap: load on; Scene 1, attribute 00 (button 1)
2 x tap: Scene 1, attribute 03 (button 3)
3 x tap: enter inclusion (pairing) mode; Scene 1, attribute 04 (button 5)
4 x tap: Scene 1, attribute 05 (button 7)
6 x tap: change LED indicator mode (see parameter 2)
10 x tap: change physical / Z-Wave control mode (see parameter 11)
tap-tap-tap-and-hold: factory reset
**Lower Paddle: **
1 x tap: load off; Scene 2, attribute 00 (button 2)
2 x tap: Scene 2, attribute 03 (button 4)
3 x tap: enter exclusion (unpairing) mode; Scene 2, attribute 04 (button 6)
4 x tap: Scene 2, attribute 05 (button 8)
tap-tap-tap-and-hold: factory reset
All ZEN26 switches can be updated via OTA firmware updates, here is how to do that. You can request a firmware update file here, please include your order number for verification!
The following table summarises the channels available for the ZEN26 -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Switch | switch_binary | switch_binary | Switch | Switch |
Scene Number | scene_number | scene_number | Number |
Switch the power on and off.
The switch_binary
channel is of type switch_binary
and supports the Switch
item and is in the Switch
category.
Triggers when a scene button is pressed.
The scene_number
channel is of type scene_number
and supports the Number
item.
This channel provides the scene, and the event as a decimal value in the form <scene>.<event>
. The scene number is set by the device, and the event is as follows -:
Event ID | Event Description |
---|---|
0 | Single key press |
1 | Key released |
2 | Key held down |
3 | Double keypress |
4 | Tripple keypress |
5 | 4 x keypress |
6 | 5 x keypress |
The following table provides a summary of the 10 configuration parameters available in the ZEN26. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Paddle control | Choose paddle functionality (invert) |
2 | LED indicator control | Change behavior of the LED indicator |
3 | Auto turn-OFF timer | Enable/disable turn-OFF timer |
4 | Auto turn-OFF timer length | Length of time before switch turns OFF |
5 | Auto turn-ON timer | Enable/disable turn-ON timer |
6 | Auto turn-ON timer length | Length of time before switch turns ON |
7 | Association reports | Association reports |
8 | ON/OFF status after power failure | Set the ON/OFF status for the switch after power failure |
10 | Enable/disable scene control | Enable/disable scene control |
11 | Enable/disable paddle control | Enable or disable local ON/OFF control |
Choose paddle functionality (invert) Choose if you want the upper paddle to turn the light ON or turn the light OFF when tapped The following option values may be configured -:
Value | Description |
---|---|
0 | Top ON, bottom OFF |
1 | Top OFF, bottom ON |
2 | Any paddle toggle |
The manufacturer defined default value is 0
(Top ON, bottom OFF).
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
Change behavior of the LED indicator Choose if you want the LED indicator to turn on when the switch (light) is ON or OFF, or if you want it to remain ON or OIFF at all times. 6 x TAP PADDLE to manually change the LED indicator mode. The following option values may be configured -:
Value | Description |
---|---|
0 | LED ON when switch OFF |
1 | LED ON when switch ON |
2 | LED OFF |
3 | LED ON |
The manufacturer defined default value is 0
(LED ON when switch OFF).
This parameter has the configuration ID config_2_1
and is of type INTEGER
.
Enable/disable turn-OFF timer Use this parameter to enable or disable the auto turn-OFF timer function The following option values may be configured -:
Value | Description |
---|---|
0 | Disable |
1 | Enable |
The manufacturer defined default value is 0
(Disable).
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
Length of time before switch turns OFF Use this parameter to set the time after which you want the switch to automatically turn OFF once it has been turned ON. The number entered as value corresponds to the number of minutes. Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 60
.
This parameter has the configuration ID config_4_4
and is of type INTEGER
.
Enable/disable turn-ON timer Use this parameter to enable or disable the auto turn-ON timer function The following option values may be configured -:
Value | Description |
---|---|
0 | Disable |
1 | Enable |
The manufacturer defined default value is 0
(Disable).
This parameter has the configuration ID config_5_1
and is of type INTEGER
.
Length of time before switch turns ON Use this parameter to set the time after which you want the switch to automatically turn ON once it has been turned OFF. The number entered as value corresponds to the number of minutes. Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 60
.
This parameter has the configuration ID config_6_4
and is of type INTEGER
.
Association reports Choose which physical and Z-Wave triggers should prompt the switch to send a status change report to associated devices.
**Values: **
0 – none
1 – physical tap on ZEN26 only
2 – physical tap on connected 3-way switch only
3 – physical tap on ZEN26 or connected 3-way switch
4 – Z-Wave command from hub
5 – physical tap on ZEN26 or Z-Wave command from hub
6 – physical tap on connected 3-way switch or Z-Wave command from hub
7 – physical tap on ZEN26 / connected 3-way switch or Z-Wave command from hub
8 – timer only; 9 – physical tap on ZEN26 or timer
10 – physical tap on connected 3-way switch or timer
11 – physical tap on ZEN26 / connected 3-way switch or timer
12 – Z-Wave command from hub or timer
13 – physical tap on ZEN26, Z-Wave command from hub, or timer
14 – physical tap on ZEN26 / connected 3-way switch, Z-Wave command from hub, or timer
15 – all of the above (default) The following option values may be configured -:
Value | Description |
---|---|
0 | None |
1 | Physical tap ZEN26 only |
2 | Physical tap 3-way switch only |
3 | Physical tap ZEN26 or 3-way switch |
4 | Z-Wave command |
5 | Physical tap ZEN26 or Z-Wave |
6 | Physical tap 3-way switch or Z-Wave |
7 | Physical tap ZEN26, 3-way switch or Z-Wave |
8 | Timer only |
9 | Physical tap ZEN26 or timer |
10 | Physical tap 3-way switch or timer |
11 | Physical tap ZEN26, 3-way switch or timer |
12 | Z-Wave command or timer |
13 | Physical tap ZEN26, Z-Wave or timer |
14 | Physical tap ZEN26, 3-way switch, Z-Wave or timer |
15 | All of the above |
The manufacturer defined default value is 15
(All of the above).
This parameter has the configuration ID config_7_1
and is of type INTEGER
.
Set the ON/OFF status for the switch after power failure
The following option values may be configured -:
Value | Description |
---|---|
0 | Off |
1 | On |
2 | Restore last state |
The manufacturer defined default value is 2
(Restore last state).
This parameter has the configuration ID config_8_1
and is of type INTEGER
.
Enable/disable scene control Enable or disable scene control functionality for quick double tap triggers The following option values may be configured -:
Value | Description |
---|---|
0 | Scene control disabled |
1 | Scene control enabled |
The manufacturer defined default value is 0
(Scene control disabled).
This parameter has the configuration ID config_10_1
and is of type INTEGER
.
Enable or disable local ON/OFF control Enable or disabvle local ON/OFF control. If enabled, you will only be able to control the connected light via Z-Wave. Scenes and other functionality will still be available through paddles. The following option values may be configured -:
Value | Description |
---|---|
0 | Local control disabled |
1 | Local control enabled |
The manufacturer defined default value is 1
(Local control enabled).
This parameter has the configuration ID config_11_1
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The ZEN26 supports 2 association groups.
The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. This device will send BINARY SWITCH REPORT to Group 1 and 2 when operated manually
Association group 1 supports 1 node.
This device will send BINARY SWITCH REPORT to Group 1 and 2 when operated manually
Association group 2 supports 5 nodes.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_CENTRAL_SCENE_V3 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V2 | |
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3 |