layout | title |
---|---|
documentation |
ZEN23 - ZWave |
{% include base.html %}
This describes the Z-Wave device ZEN23, manufactured by Zooz with the thing type UID of zooz_zen23v3_03_000
.
This version of the device is limited to firmware versions above 3.0
The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.
The ZEN23 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
FEATURES
- Manual or remote on/off control from your mobile device or computer (when included to a Z-Wave gateway controller)
- Z-Wave Plus with improved 500 chip for faster and safer wireless communication
- Works with LED, CFL, and incandescent bulbs (minimum 15Watts on load required)
- Based on simple and universal binary switch command class - supported by most Z-Wave controllers
- May be associated and grouped with other Z-Wave devices for advanced home automation
- Built-in Z-Wave signal repeater for a stronger and more reliable network
- Bring your Z-Wave gateway hub or controller within direct range of the switch
- Put your Z-Wave controller in inclusion mode
- Toggle the switch up quickly 3 times to finalize the inclusion process
- A new on/off device should appear on your controller's device list
- Bring your Z-Wave gateway hub or controller within direct range of the switch
- Put your Z-Wave controller in exclusion mode
- Toggle the switch down quickly 3 times to complete the exclusion process
- The device should disappear from your controller's device list
Please repeat the process following all steps carefully if the first attempt is unsuccessful
Optional Scene Control:
2 x Toggle Up: Trigger Scene 1
2 x Toggle Down: Trigger Scene 2
Troubleshooting Tips:
If you are unable to include the Toggle Switch to your controller, please try one of the following:
- Bring the controller closer to your Z-Wave switch or use a hand-held secondary controller for inclusion
- Toggle your Z-Wave switch quicker 6 or 7 times once you put the controller in the inclusion mode to ensure the command has gone through
- Put your controller in the EXCLUSION mode and toggle the switch quickly 3 times, then try adding it to your network agai
Factory Reset:
If your primary controller is missing or inoperable, you may need to reset
the device to factory settings. To complete the reset process manually,
toggle-toggle-toggle’n’hold down for at least 10 seconds.
NOTE: All previously recorded activity and custom settings will be erased from the device’s memory
The following table summarises the channels available for the ZEN23 -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Switch | switch_binary | switch_binary | Switch | Switch |
Scene Number | scene_number | scene_number | Number |
Switch the power on and off.
The switch_binary
channel is of type switch_binary
and supports the Switch
item and is in the Switch
category.
Triggers when a scene button is pressed.
The scene_number
channel is of type scene_number
and supports the Number
item.
This channel provides the scene, and the event as a decimal value in the form <scene>.<event>
. The scene number is set by the device, and the event is as follows -:
Event ID | Event Description |
---|---|
0 | Single key press |
1 | Key released |
2 | Key held down |
3 | Double keypress |
4 | Tripple keypress |
5 | 4 x keypress |
6 | 5 x keypress |
The following table provides a summary of the 7 configuration parameters available in the ZEN23. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Toggle Control | Determines whether up is on and down is off; or up is off, down is on |
3 | Auto Turn-Off Timer | Use this parameter to enable or disable the auto turn-off timer |
4 | Auto Turn-Off Timer Time | Time after which the switch automatically turns off |
5 | Auto Turn-On Timer | Use this parameter to enable or disable the auto turn-on timer |
6 | Auto Turn-On Timer Time | Set the time after which the switch automatically turns on |
8 | On Off Status After Power Failure | Set the on off status for the switch after power failure |
9 | Enable/Disable Scene Control | Enable or disable scene control functionality for quick 2-tap. |
Determines whether up is on and down is off; or up is off, down is on Toggle Control
Parameter 1: Choose if you want the to turn the light on by clicking the toggle up or down
Values:
0 – Toggle up turns the light on, toggle down turns the light off (default);
1 – Toggle up turns the light off, toggle down turns the light on
The following option values may be configured -:
Value | Description |
---|---|
0 | UP=On, DOWN=Off |
1 | UP=Off, DOWN=On |
The manufacturer defined default value is 0
(UP=On, DOWN=Off).
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
Use this parameter to enable or disable the auto turn-off timer Use this parameter to enable or disable the auto turn-off timer
Values:
0 – timer disabled (default)
1 – timer enabled
The following option values may be configured -:
Value | Description |
---|---|
0 | Auto Turn-Off Timer Disabled |
1 | Auto Turn-Off Timer Enabled |
The manufacturer defined default value is 0
(Auto Turn-Off Timer Disabled).
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
Time after which the switch automatically turns off Use this parameter to set the time after which you want the switch to automatically turn off once it has been turned on. The number entered as value corresponds to the number of minutes.
Values:
1 – 65535 (minutes).
60 – default.
Values in the range 1 to 65535 may be set.
The manufacturer defined default value is 60
.
This parameter has the configuration ID config_4_4
and is of type INTEGER
.
Use this parameter to enable or disable the auto turn-on timer Use this parameter to enable or disable the auto turn-on timer
Values:
0 – timer disabled (default)
1 – timer enabled.
The following option values may be configured -:
Value | Description |
---|---|
0 | Auto Turn-On Timer Disabled |
1 | Auto Turn-On Timer Enabled |
The manufacturer defined default value is 0
(Auto Turn-On Timer Disabled).
This parameter has the configuration ID config_5_1
and is of type INTEGER
.
Set the time after which the switch automatically turns on Use this parameter to set the time after which you want the switch to automatically turn on once it has been turned off. The number entered as value corresponds to the number of minutes.
Values:
1 – 65535 (minutes). Default set to 60 Values in the range 1 to 65535 may be set.
The manufacturer defined default value is 60
.
This parameter has the configuration ID config_6_4
and is of type INTEGER
.
Set the on off status for the switch after power failure Parameter 8: Set the on off status for the switch after power failure.
Values:
0 – forced to OFF (regardless of state prior to power outage);
1 – forced to ON (regardless of state prior to power outage);
2 – remembers and restores on/off status after power failure (default)
The following option values may be configured -:
Value | Description |
---|---|
0 | forced to OFF |
1 | forced to ON |
2 | Restore Previous Status |
The manufacturer defined default value is 2
(Restore Previous Status).
This parameter has the configuration ID config_8_1
and is of type INTEGER
.
Enable or disable scene control functionality for quick 2-tap. Enable or disable scene control functionality for quick 2-tap.
Values:
0 – scene control disabled (default).
1 – scene control enabled.
The following option values may be configured -:
Value | Description |
---|---|
0 | Disable Scene Control |
1 | Enable Scene Control |
The manufacturer defined default value is 0
(Disable Scene Control).
This parameter has the configuration ID config_9_1
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The ZEN23 supports 2 association groups.
The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation.
Association group 1 supports 1 node.
BASIC Command Set
Association group 2 supports 5 nodes.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_CENTRAL_SCENE_V3 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V2 | |
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3 |