layout | title |
---|---|
documentation |
ZEN23 - ZWave |
{% include base.html %}
This describes the Z-Wave device ZEN23, manufactured by Zooz with the thing type UID of zooz_zen23_00_000
.
This version of the device is limited to firmware versions below 2.9
The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.
The ZEN23 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. Refer to the Wakeup Information section below for further information.
Optimal Wireless Control
Monitor and command your lights remotely using your mobile device — turn your basement lights off while you’re lying in bed.
Direct 3-Way Solution
Wire this Z-Wave switch with your existing 3-way switch. Now you only need one smart switch to monitor and control lights from 2 locations!
Advanced Automation
Associate with other Z-Wave devices for lighting scenes and events designed around your life.
Stronger Connection
A toggle that doubles as a signal repeater to give you a faster and more reliable Z-Wave network overall.
Wide Compatibility
Connect this Z-Wave toggle with dozens of smart home systems and brands. Pair it with LED, CFL, and incandescent bulbs.
- Bring your Z-Wave gateway hub or controller as close to the switch as possible
- Put your Z-Wave controller into inclusion mode
- Toggle the switch UP 3 times very quickly to finalize the inclusion process
- A new on/off device will appear on your controller's device list
- Bring your Z-Wave gateway hub or controller as close to the switch as possible
- Put your Z-Wave controller into exclusion mode
- Toggle the switch DOWN 3 times very quickly to complete the exclusion process
- The device will disappear from your controller's device list
The ZEN23 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour.
The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
Toggle the switch up or down once
The following table summarises the channels available for the ZEN23 -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Switch | switch_binary | switch_binary | Switch | Switch |
Switch the power on and off.
The switch_binary
channel is of type switch_binary
and supports the Switch
item and is in the Switch
category.
The following table provides a summary of the 1 configuration parameters available in the ZEN23. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Toggle Control | Determines whether up is on and down is off; or up is off, down is on |
Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands |
Determines whether up is on and down is off; or up is off, down is on Toggle Control
Parameter 1: Choose if you want the to turn the light on by clicking the toggle up or down
Values: 0 – Toggle up turns the light on, toggle down turns the light off (default);
1 – Toggle up turns the light off, toggle down turns the light on
Size: 1 byte dec. Values in the range 0 to 1 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
Set the mode for the switch when receiving SWITCH ALL commands.
The following option values may be configured -:
Value | Description |
---|---|
0 | Exclude from All On and All Off groups |
1 | Include in All On group |
2 | Include in All Off group |
255 | Include in All On and All Off groups |
This parameter has the configuration ID switchall_mode
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The ZEN23 supports 1 association group.
Association group 1 supports 5 nodes.
Command Class | Comment |
---|---|
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_SWITCH_ALL_V1 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V2 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V2 |
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.