ZEN23 Toggle Switch v1

This describes the Z-Wave device ZEN23, manufactured by Zooz with the thing type UID of zooz_zen23_00_000. This version of the device is limited to firmware versions below 2.9

The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.

ZEN23 product image

The ZEN23 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. Refer to the Wakeup Information section below for further information.

Overview

Optimal Wireless Control

Monitor and command your lights remotely using your mobile device — turn your basement lights off while you’re lying in bed.

Direct 3-Way Solution

Wire this Z-Wave switch with your existing 3-way switch. Now you only need one smart switch to monitor and control lights from 2 locations!

Advanced Automation

Associate with other Z-Wave devices for lighting scenes and events designed around your life.

Stronger Connection

A toggle that doubles as a signal repeater to give you a faster and more reliable Z-Wave network overall.

Wide Compatibility

Connect this Z-Wave toggle with dozens of smart home systems and brands. Pair it with LED, CFL, and incandescent bulbs.

Inclusion Information

  1. Bring your Z-Wave gateway hub or controller as close to the switch as possible
  2. Put your Z-Wave controller into inclusion mode
  3. Toggle the switch UP 3 times very quickly to finalize the inclusion process
  4. A new on/off device will appear on your controller's device list

Exclusion Information

  1. Bring your Z-Wave gateway hub or controller as close to the switch as possible
  2. Put your Z-Wave controller into exclusion mode
  3. Toggle the switch DOWN 3 times very quickly to complete the exclusion process
  4. The device will disappear from your controller's device list

Wakeup Information

The ZEN23 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour.

The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.

Toggle the switch up or down once

Channels

The following table summarises the channels available for the ZEN23 -:

Channel Name Channel ID Channel Type Category Item Type
Switch switch_binary switch_binary Switch Switch

Switch

Switch the power on and off.

The switch_binary channel is of type switch_binary and supports the Switch item and is in the Switch category.

Device Configuration

The following table provides a summary of the 1 configuration parameters available in the ZEN23. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Toggle Control Determines whether up is on and down is off; or up is off, down is on
Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Parameter 1: Toggle Control

Determines whether up is on and down is off; or up is off, down is on Toggle Control

Parameter 1: Choose if you want the to turn the light on by clicking the toggle up or down

Values: 0 – Toggle up turns the light on, toggle down turns the light off (default);

1 – Toggle up turns the light off, toggle down turns the light on

Size: 1 byte dec. Values in the range 0 to 1 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -:

Value Description
0 Exclude from All On and All Off groups
1 Include in All On group
2 Include in All Off group
255 Include in All On and All Off groups

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The ZEN23 supports 1 association group.

Group 1: Group 1

Association group 1 supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC
COMMAND_CLASS_SWITCH_ALL_V1
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V2
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_VERSION_V2