ZEN07 Mini Plug

This describes the Z-Wave device ZEN07, manufactured by Zooz with the thing type UID of zooz_zen07_00_000.

The device is in the category of Power Outlet, defining Small devices to be plugged into a power socket in a wall which stick there.

ZEN07 product image

The ZEN07 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

You have picked the finest solution for your smart home, congratulations! Now it's time to enjoy these great features of your new Mini Plug:

  • Wireless and manual on / off control of floor lamps and small appliances
  • Energy monitoring in live mode or over time (your Z-Wave gateway needs to support this feature)
  • Scene inclusion for custom automation scenarios when included to a Z-Wave gateway controller
  • Advanced configuration to customize LED indicator display and Z-Wave button functionality
  • Automatic status recovery after power outage
  • Timer option to turn off the device automatically (your Z-Wave gateway needs to support this feature)
  • Z-Wave Plus with improved 500 chip for faster and safer wireless communication
  • Built-in range extender for a stronger, more reliable network
  • Super small size – easily fits two in a standard double receptacle

Inclusion Information

Press and release the Z-Wave button on the Mini Plug 3 TIMES quickly.

The LED indicator will flash green. It will turn solid green once the process has been completed

Exclusion Information

Press and release the Z-Wave button 3 TIMES quickly. The LED indicator will flash pink

Channels

The following table summarises the channels available for the ZEN07 -:

Channel Name Channel ID Channel Type Category Item Type
Switch switch_binary switch_binary Switch Switch
Electric meter (kWh) meter_kwh meter_kwh Energy Number
Electric meter (amps) meter_current meter_current Energy Number
Electric meter (watts) meter_watts meter_watts Energy Number
Electric meter (volts) meter_voltage meter_voltage Energy Number
Alarm (power) alarm_power alarm_power Energy Switch

Switch

Switch the power on and off.

The switch_binary channel is of type switch_binary and supports the Switch item and is in the Switch category.

Electric meter (kWh)

Indicates the energy consumption (kWh).

The meter_kwh channel is of type meter_kwh and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (amps)

Indicates the instantaneous current consumption.

The meter_current channel is of type meter_current and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (watts)

Indicates the instantaneous power consumption.

The meter_watts channel is of type meter_watts and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (volts)

Indicates the instantaneous voltage.

The meter_voltage channel is of type meter_voltage and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Alarm (power)

Indicates if a power alarm is triggered.

The alarm_power channel is of type alarm_power and supports the Switch item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Device Configuration

The following table provides a summary of the 10 configuration parameters available in the ZEN07. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Metering Report send metering reports
2 Metering Report Frequency Frecuency metering reports to the controller.
3 Overload Protection Maximum amount of electricity Mini Plug to handle.
4 Overload Protection Notification LED notifications of heavy load.
5 LED Notifications Use this parameter to turn LED notifications on or off
6 Power Report Percentage Threshold Mini Plug to report energy usage percentage rate.
7 On/Off Status Recovery After Power Failure Choose the recovery state for your Mini Plug if power outage occurs
8 Auto Turn-Off Timer Enable : Use this parameter to enable or disable the auto turn-off timer function
9 Auto Turn-Off Timer Interval Set the time to automatically turn off
10 Manual Control Turn the Mini Plug with button
Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Parameter 1: Metering Report

send metering reports Choose if you want the Mini Plug to send metering reports to the controller. Values: 0 – Disabled; 1 – Enabled (default). The following option values may be configured -:

Value Description
0 Disabled
1 Enabled (default).

The manufacturer defined default value is 1 (Enabled (default).).

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Parameter 2: Metering Report Frequency

Frecuency metering reports to the controller. Choose how often you want the Mini Plug to send metering reports to the controller. The number entered as the value corresponds to the number of seconds. So if 300 is entered by default, the Mini Plug will report power consumption every 300 seconds (5 minutes). Values in the range 1 to 65535 may be set.

The manufacturer defined default value is 300.

This parameter has the configuration ID config_2_2 and is of type INTEGER.

Parameter 3: Overload Protection

Maximum amount of electricity Mini Plug to handle. Use this parameter to adjust the maximum amount of electricity you want your Mini Plug to handle. The number entered as the value corresponds to the number of Amperes. Overload protection will turn the Mini Plug’s relay off once load exceeds 13A by default. It will also send a notification (NOTIFICATION_EVENT_POWER_MANAGEMENT_OVER_LOAD_DETECTED) to the controller and all associated devices. LED indicator on the device will blink red until the load is disconnected. Press the Z-Wave button ONCE to switch the alarm off. The value set in this parameter needs to be greater than the value in parameter 4.  Values in the range 1 to 16 may be set.

The manufacturer defined default value is 13.

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Parameter 4: Overload Protection Notification

LED notifications of heavy load. Use this parameter to adjust electricity value for LED notifications of heavy load. The LED indicator on the Mini Plug will light up yellow once electricity from the load is greater than the value set in this parameter. The relay will NOT turn off. The value set in this parameter can NOT be greater than the value in parameter 3. Values: 1 – 13 (Amperes) or whatever the value set in parameter 3. 12 (Amperes) – default setting.  Values in the range 1 to 13 may be set.

The manufacturer defined default value is 12.

This parameter has the configuration ID config_4_1 and is of type INTEGER.

Parameter 5: LED Notifications

Use this parameter to turn LED notifications on or off Use this parameter to turn LED notifications on or off. Values: 0 – LED disabled; 1 – LED enabled (default). The following option values may be configured -:

Value Description
0 LED disabled
1 LED enabled (default)

The manufacturer defined default value is 1 (LED enabled (default)).

This parameter has the configuration ID config_5_1 and is of type INTEGER.

Parameter 6: Power Report Percentage Threshold

Mini Plug to report energy usage percentage rate. Choose how you want your Mini Plug to report power consumption, electricity, voltage, and energy usage to your controller and associated devices by percentage rate. The number entered as the value corresponds to the change in percentage the appliance needs to go over for the event to be reported. So if 5% is entered by default, the Mini Plug will report any change in power consumption (W), voltage (V), electricity (A), or energy usage (kWH) over 5% (whether it’s at least 5% more or 5% less compared to previous report). Values: 1 – 100 (%); 5 (%) – default setting Values in the range 1 to 100 may be set.

The manufacturer defined default value is 5.

This parameter has the configuration ID config_6_1 and is of type INTEGER.

Parameter 7: On/Off Status Recovery After Power Failure

Choose the recovery state for your Mini Plug if power outage occurs Choose the recovery state for your Mini Plug if power outage occurs. Values: 0 – Mini Plug automatically turns OFF once power is restored (it does not remember the status prior to power outage); 1 – Mini Plug remembers the status prior to power outage and turns back to it (default);  The following option values may be configured -:

Value Description
0 OFF once power is restored
1 Remembers the status

The manufacturer defined default value is 1 (Remembers the status).

This parameter has the configuration ID config_7_1 and is of type INTEGER.

Parameter 8: Auto Turn-Off Timer Enable

: Use this parameter to enable or disable the auto turn-off timer function Use this parameter to enable or disable the auto turn-off timer function. If this feature is enabled, the Mini Plug will automatically turn off after a fixed period of time (set in parameter 9). Values: 0 – timer disabled (default); 1 – timer enabled  The following option values may be configured -:

Value Description
0 timer disabled (default)
1 timer enabled

The manufacturer defined default value is 0 (timer disabled (default)).

This parameter has the configuration ID config_8_1 and is of type INTEGER.

Parameter 9: Auto Turn-Off Timer Interval

Set the time to automatically turn off Use this parameter to set the time after which you want the Mini Plug to automatically turn off once it has been turned on. The number entered as value corresponds to the number of minutes. Values: 1 – 65535 (minutes); 150 (minutes) – default setting.  Values in the range 1 to 65535 may be set.

The manufacturer defined default value is 150.

This parameter has the configuration ID config_9_2 and is of type INTEGER.

Parameter 10: Manual Control

Turn the Mini Plug with button Choose if you want to use the Z-Wave button to turn the Mini Plug on or off manually or if you want to disable this function. If this parameter is set to 0 (disabled), you will only be able to turn the Mini Plug on or off remotely using your Z-Wave gateway controller. Values: 0 – manual control disabled; 1 – manual control enabled (default)  The following option values may be configured -:

Value Description
0 manual control disabled
1 manual control enabled (default)

The manufacturer defined default value is 1 (manual control enabled (default) ).

This parameter has the configuration ID config_10_1 and is of type INTEGER.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -:

Value Description
0 Exclude from All On and All Off groups
1 Include in All On group
2 Include in All Off group
255 Include in All On and All Off groups

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The ZEN07 supports 3 association groups.

Group 1: Lifeline

The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation.

Association group 1 supports 5 nodes.

Group 2: Group 2

Group 2 for status and overload communication to other Z-Wave devices in the network.

Supported command classes: BASIC_SET

Association group 2 supports 5 nodes.

Group 3: Group 3

Group 3 for notifications to Z-Wave devices associated in this group.

Supported command classes: NOTIFICATION_REPORT_V4

Association group 3 supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC
COMMAND_CLASS_SWITCH_ALL_V1
COMMAND_CLASS_METER_V3
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_ALARM_V4
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_VERSION_V2

Documentation Links


Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.