layout | title |
---|---|
documentation |
ZIP-PAB01 - ZWave |
{% include base.html %}
This describes the Z-Wave device ZIP-PAB01, manufactured by Zipato with the thing type UID of zipato_zippab01_00_000
.
The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.
The ZIP-PAB01 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
- Slim, compact remote Z-Wave module measures power parameters of connected device
- Dual power meter function
- Instant power wattage and
- Accumulated power consumption KWh report
- Amper meter clamp included in the box
- Maximum current measure 60A
- Higher output power enhances communication range(+2.5dBm output power compared to -2.5dBm 300 series)
- New Z-Wave 500 series chip supports multichannel operation and higher data rates (9.6/40/100kbps)
- Very low power power consumption
- Over-the-air firmware update Easy installation
In the front casing, there is an On/Off button with LED indicator which is used to carry out inclusion, exclusion, reset or association. After being excluded, its LED flashes on and off alternately and repeatedly at 2-second intervals. It implies that it has not been assigned a node ID and cannot work with Z-Wave enabled devices.
AUTO INCLUSION
The function of auto inclusion will be executed as long as the Micromodule does not have Node ID and is plugged into a wall outlet. When first power is applied, its LED flashes on and off alternately and repeatedly at 0.5 second intervals. It implies that it is in learning mode now.
Note: Auto inclusion timeout lasts 2 minutes during which the node information of explorer frame will be emitted once per every 5 seconds. Unlike “inclusion” function as shown in the table below, auto inclusion doesn’t require pressing on/off buttons on the switch.
Pressing On/Off (Include) button three times within 2 seconds will enter exclusion mode.
The following table summarises the channels available for the ZIP-PAB01 -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Electric meter (volts) | meter_voltage | meter_voltage | Energy | Number |
Electric meter (kWh) | meter_kwh | meter_kwh | Energy | Number |
Electric meter (amps) | meter_current | meter_current | Energy | Number |
Electric meter (power factor) | meter_powerfactor | meter_powerfactor | Energy | Number |
Electric meter (watts) | meter_watts | meter_watts | Energy | Number |
Meter Reset | meter_reset | meter_reset | Energy | Switch |
Electric meter (volts) 1 | meter_voltage1 | meter_voltage | Energy | Number |
Electric meter (kWh) 1 | meter_kwh1 | meter_kwh | Energy | Number |
Electric meter (amps) 1 | meter_current1 | meter_current | Energy | Number |
Electric meter (power factor) 1 | meter_powerfactor1 | meter_powerfactor | Energy | Number |
Electric meter (watts) 1 | meter_watts1 | meter_watts | Energy | Number |
Meter Reset | meter_reset1 | meter_reset | Energy | Switch |
Electric meter (volts) 2 | meter_voltage2 | meter_voltage | Energy | Number |
Electric meter (kWh) 2 | meter_kwh2 | meter_kwh | Energy | Number |
Electric meter (amps) 2 | meter_current2 | meter_current | Energy | Number |
Electric meter (power factor) 2 | meter_powerfactor2 | meter_powerfactor | Energy | Number |
Electric meter (watts) 2 | meter_watts2 | meter_watts | Energy | Number |
Electric meter (volts) 3 | meter_voltage3 | meter_voltage | Energy | Number |
Electric meter (kWh) 3 | meter_kwh3 | meter_kwh | Energy | Number |
Electric meter (amps) 3 | meter_current3 | meter_current | Energy | Number |
Electric meter (power factor) 3 | meter_powerfactor3 | meter_powerfactor | Energy | Number |
Electric meter (watts) 3 | meter_watts3 | meter_watts | Energy | Number |
Indicates the instantaneous voltage.
The meter_voltage
channel is of type meter_voltage
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the energy consumption (kWh).
The meter_kwh
channel is of type meter_kwh
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous current consumption.
The meter_current
channel is of type meter_current
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous power factor.
The meter_powerfactor
channel is of type meter_powerfactor
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous power consumption.
The meter_watts
channel is of type meter_watts
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Reset the meter.
The meter_reset
channel is of type meter_reset
and supports the Switch
item and is in the Energy
category.
Indicates the instantaneous voltage.
The meter_voltage1
channel is of type meter_voltage
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the energy consumption (kWh).
The meter_kwh1
channel is of type meter_kwh
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous current consumption.
The meter_current1
channel is of type meter_current
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous power factor.
The meter_powerfactor1
channel is of type meter_powerfactor
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous power consumption.
The meter_watts1
channel is of type meter_watts
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Reset the meter.
The meter_reset1
channel is of type meter_reset
and supports the Switch
item and is in the Energy
category.
Indicates the instantaneous voltage.
The meter_voltage2
channel is of type meter_voltage
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the energy consumption (kWh).
The meter_kwh2
channel is of type meter_kwh
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous current consumption.
The meter_current2
channel is of type meter_current
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous power factor.
The meter_powerfactor2
channel is of type meter_powerfactor
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous power consumption.
The meter_watts2
channel is of type meter_watts
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous voltage.
The meter_voltage3
channel is of type meter_voltage
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the energy consumption (kWh).
The meter_kwh3
channel is of type meter_kwh
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous current consumption.
The meter_current3
channel is of type meter_current
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous power factor.
The meter_powerfactor3
channel is of type meter_powerfactor
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous power consumption.
The meter_watts3
channel is of type meter_watts
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
The following table provides a summary of the 3 configuration parameters available in the ZIP-PAB01. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Power meter report period | Power meter report period, in 5 seconds unit. 720 -> 1 hour |
2 | Energy meter report period | The accumulated power consumption report period |
3 | Selected default endpoint | 1 => CT1 and CT2, 2 => CT1, 3 => CT2 |
Power meter report period, in 5 seconds unit. 720 -> 1 hour If the setting is configured for 1 hour (set value 720), the module will report its instant power consumption every 1 hour to the node of the corresponding group. The maximum interval to report its instant power consumption is 45h (5s * 32767 / 3600 = 45h) Values in the range 1 to 32767 may be set.
The manufacturer defined default value is 720
.
This parameter has the configuration ID config_1_2
and is of type INTEGER
.
The accumulated power consumption report period If the setting is configured for 1 hour (set value 720), the module will report its accumulated power consumption every 1 hour to the node of the corresponding group. The maximum interval to report its accumulated power consumption is 45h (5s * 32767 / 3600 = 45h) Values in the range 1 to 32767 may be set.
The manufacturer defined default value is 720
.
This parameter has the configuration ID config_2_2
and is of type INTEGER
.
1 => CT1 and CT2, 2 => CT1, 3 => CT2 If Controller does not use Multi Channel command class to access the endpoint of the module, you may configure the endpoint that will react to the Basic Command Class, Binary Switch command class or Meter command class V3. Values in the range 1 to 3 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The ZIP-PAB01 supports 3 association groups.
Sum of CT1 and CT2 Sum of :
- Instant power consumption from CT1 and CT2 (W)
- Accumulated power consumption from CT1 and CT2 (kWh)
Association group 1 supports 1 node.
Data from CT1
- Instant power consumption from CT1 (W)
- Accumulated power consumption from CT1 (kWh)
Association group 2 supports 1 node.
Data from CT2
- Instant power consumption from CT2 (W)
- Accumulated power consumption from CT2 (kWh)
Association group 3 supports 1 node.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_METER_V3 | |
COMMAND_CLASS_CRC_16_ENCAP_V1 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_MULTI_CHANNEL_V2 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V2 | |
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3 |
Command Class | Comment |
---|---|
COMMAND_CLASS_METER_V3 |
Command Class | Comment |
---|---|
COMMAND_CLASS_METER_V3 |
Command Class | Comment |
---|---|
COMMAND_CLASS_METER_V3 |
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.