layout | title |
---|---|
documentation |
Keyless Connected Smart Door Lock - ZWave |
{% include base.html %}
This describes the Z-Wave device Keyless Connected Smart Door Lock, manufactured by ASSA ABLOY with the thing type UID of yale_keylesslock_00_000
.
The device is in the category of Lock, defining Devices whose primary pupose is locking something.
The Keyless Connected Smart Door Lock supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.
The Yale Keyless Connected Smart Door Lock can have Z-Wave® and Yale modules added to allow easy integration to smart home systems.
For more information on how to connect your smart door lock to a Yale system go to www.yale.co.uk/YaleEcoSystem. For other home automation systems please follow their instructions on adding a lock and when prompted follow the instructions below.
Touch the keypad with the palm of your hand. Enter the master code, followed by # key. Press the [4] button followed by # key. Press the [1] button followed by the # key. Please wait up to 60 seconds.
For security reasons a lock will not connect to a new home automation system if it is linked to another. If you have changed your home automation system please remove the device from the old system before adding it on to the new one.
Touch the keypad with the palm of your hand. Enter the master code, followed by # key. Press the [4] button followed by # key. Press the [3] button followed by the # key. Please wait up to 60 seconds.
The following table summarises the channels available for the Keyless Connected Smart Door Lock -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Door Lock | lock_door | lock_door | Door | Switch |
Alarm (general) | alarm_general | alarm_general | Alarm | Switch |
Alarm (access) | alarm_access | alarm_access | Door | Switch |
Alarm (power) | alarm_power | alarm_power | Energy | Switch |
Alarm (raw) | alarm_raw | alarm_raw | String | |
Battery Level | battery-level | system.battery_level | Battery | Number |
Clock Time Offset | time_offset | time_offset | Time | Number |
Lock and unlock the door.
The lock_door
channel is of type lock_door
and supports the Switch
item and is in the Door
category.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
ON | Locked |
OFF | Unlocked |
Indicates if an alarm is triggered.
The alarm_general
channel is of type alarm_general
and supports the Switch
item and is in the Alarm
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
Indicates if the access control alarm is triggered.
The alarm_access
channel is of type alarm_access
and supports the Switch
item and is in the Door
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
Indicates if a power alarm is triggered.
The alarm_power
channel is of type alarm_power
and supports the Switch
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
Provides alarm parameters as json string.
The alarm_raw
channel is of type alarm_raw
and supports the String
item. This is a read only channel so will only be updated following state changes from the device.
This channel sets, and provides the alarm state as a JSON string. It is designed for use in rules.
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
The system.battery-level
channel is of type system.battery-level
and supports the Number
item and is in the Battery
category.
This channel provides the battery level as a percentage and also reflects the low battery warning state. If the battery state is in low battery warning state, this will read 0%.
Provides the current time difference for the devices time.
The time_offset
channel is of type time_offset
and supports the Number
item and is in the Time
category.
The following table provides a summary of the 4 configuration parameters available in the Keyless Connected Smart Door Lock. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Audio Volume | Sets the volume level of the beeps and voice prompts |
2 | Auto Re-lock | When enabled, the unit will automatically re-lock |
3 | Re-lock Time | Time after unlocking that the device will lock |
4 | Wrong Code Entry Limit | The number of invalid tries before the lock shutdowns and sends an alarm |
Lock Timeout | Sets the time after which the door will auto lock |
Sets the volume level of the beeps and voice prompts 1 = Silent 2 = Low 3 = High The following option values may be configured, in addition to values in the range 1 to 3 -:
Value | Description |
---|---|
1 | Silent |
2 | Low |
3 | High |
The manufacturer defined default value is 3
(High).
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
When enabled, the unit will automatically re-lock 0 = Off 255 = On The following option values may be configured, in addition to values in the range 0 to 255 -:
Value | Description |
---|---|
255 | On |
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_2_1
and is of type INTEGER
.
Time after unlocking that the device will lock
Values in the range 7 to 90 may be set.
The manufacturer defined default value is 7
.
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
The number of invalid tries before the lock shutdowns and sends an alarm
Values in the range 1 to 7 may be set.
The manufacturer defined default value is 3
.
This parameter has the configuration ID config_4_1
and is of type INTEGER
.
Sets the time after which the door will auto lock.
This parameter has the configuration ID doorlock_timeout
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The Keyless Connected Smart Door Lock supports 1 association group.
Alarm reports are sent out to all devices in the association group
Association group 1 supports 5 nodes.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_DOOR_LOCK_LOGGING_V1 | |
COMMAND_CLASS_SCHEDULE_ENTRY_LOCK_V1 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_DOOR_LOCK_V1 | |
COMMAND_CLASS_USER_CODE_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_ALARM_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_BATTERY_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V2 | |
COMMAND_CLASS_TIME_V1 | |
COMMAND_CLASS_TIME_PARAMETERS_V1 | |
COMMAND_CLASS_SECURITY_V1 |
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.