layout | title |
---|---|
documentation |
ZW691 - ZWave |
{% include base.html %}
This describes the Z-Wave device ZW691, manufactured by Willis Electric Co., Ltd. with the thing type UID of willis_zw691_00_000
.
The device is in the category of Power Outlet, defining Small devices to be plugged into a power socket in a wall which stick there.
The ZW691 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. Refer to the Wakeup Information section below for further information.
This ZW691 Duplex Receptacle is designed to work with other Z-WAVE enabled devices. Z-WAVE nodes of other types can be Included in the system and will also act as repeaters.This is useful when the device would otherwise be out of the radio range of the wireless controller. The top outlet is active and the bottom is controlled through Z-wave or through the manual button on the outlet as is typical for a Z-wave outle
Press the learn switch of ZW691 three times for 1 second at least & release to be excluded
The ZW691 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour.
The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
The following table summarises the channels available for the ZW691 -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Switch | switch_binary | switch_binary | Switch | Switch |
Electric meter (kWh) | meter_kwh | meter_kwh | Energy | Number |
Electric meter (volts) | meter_voltage | meter_voltage | Energy | Number |
Electric meter (amps) | meter_current | meter_current | Energy | Number |
Electric meter (watts) | meter_watts | meter_watts | Energy | Number |
Electric meter (kVAh) | meter_kvah | meter_kvah | Energy | Number |
Switch the power on and off.
The switch_binary
channel is of type switch_binary
and supports the Switch
item and is in the Switch
category.
Indicates the energy consumption (kWh).
The meter_kwh
channel is of type meter_kwh
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous voltage.
The meter_voltage
channel is of type meter_voltage
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous current consumption.
The meter_current
channel is of type meter_current
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous power consumption.
The meter_watts
channel is of type meter_watts
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the energy consumption (kVAh).
The meter_kvah
channel is of type meter_kvah
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
The device has no configuration parameters defined.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The device does not support associations.
Command Class | Comment |
---|---|
COMMAND_CLASS_SWITCH_BINARY_V1 | |
COMMAND_CLASS_SWITCH_ALL_V1 | |
COMMAND_CLASS_METER_V3 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V2 |
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.