layout | title |
---|---|
documentation |
ZEN24 - ZWave |
{% include base.html %}
This describes the Z-Wave device ZEN24, manufactured by Willis Electric Co., Ltd. with the thing type UID of willis_zen24_00_000
.
The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.
The ZEN24 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
Replace a classic dimmer switch with this smart Z-Wave Plus ZEN24 equivalent and control lighting, adjust brightness, or recreate settings remotely.
. Toggle the switch up and down quickly 3 times to finalize the inclusion process
Toggle the switch up and down quickly 3 times to complete the exclusion process
The following table summarises the channels available for the ZEN24 -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Dimmer | switch_dimmer | switch_dimmer | DimmableLight | Dimmer |
The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.
The switch_dimmer
channel is of type switch_dimmer
and supports the Dimmer
item and is in the DimmableLight
category.
The following table provides a summary of the 1 configuration parameters available in the ZEN24. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Control Mode | Control Mode |
Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands |
Control Mode firmware 20.15 only (released in 12/2016) The following option values may be configured -:
Value | Description |
---|---|
0 | Mode 1 |
1 | Mode 2 |
The manufacturer defined default value is 1
(Mode 2).
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
Set the mode for the switch when receiving SWITCH ALL commands.
The following option values may be configured -:
Value | Description |
---|---|
0 | Exclude from All On and All Off groups |
1 | Include in All On group |
2 | Include in All Off group |
255 | Include in All On and All Off groups |
This parameter has the configuration ID switchall_mode
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The ZEN24 supports 1 association group.
The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation.
Association group 1 supports 5 nodes.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_MULTILEVEL_V1 | Linked to BASIC |
COMMAND_CLASS_SWITCH_ALL_V1 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V2 |