layout | title |
---|---|
documentation |
ZM1702 - ZWave |
{% include base.html %}
This describes the Z-Wave device ZM1702, manufactured by Vision Security with the thing type UID of vision_zm1702_00_000
.
The device is in the category of Lock, defining Devices whose primary pupose is locking something.
The ZM1702 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.
The ZM1702 is a Z-Wave controllable, single dead bolt lock. The mechanics can be adopted to right or left opening doors. The door lock can be applied for doors from a thickness of 38 mm and up. The door can be locked and unlocked using the inner side turn piece and/or the key pad. The wireless control allows to lock/unlock the lock, set/unset up to 15 different key codes (4 - 8 key long) and to limit the validity of certain key code.
Press Keypads 'C', '8', '8', '8' and manually turn the door lock from inside to be included.
Press Keypads 'C', '8', '8', '8' and manually turn the door lock from inside to be excluded.
The following table summarises the channels available for the ZM1702 -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Door Lock | lock_door | lock_door | Door | Switch |
Battery Level | battery-level | system.battery_level | Battery | Number |
Entry Alarm | alarm_entry | alarm_entry | Door | Switch |
Lock and unlock the door.
The lock_door
channel is of type lock_door
and supports the Switch
item and is in the Door
category.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
ON | Locked |
OFF | Unlocked |
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
The system.battery-level
channel is of type system.battery-level
and supports the Number
item and is in the Battery
category.
This channel provides the battery level as a percentage and also reflects the low battery warning state. If the battery state is in low battery warning state, this will read 0%.
Indicates if the entry alarm is triggered.
The alarm_entry
channel is of type alarm_entry
and supports the Switch
item and is in the Door
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
ON | Open |
OFF | Closed |
The device has no configuration parameters defined.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The ZM1702 supports 1 association group.
Target for Door Lock Operation Report commands Support one group (5 nodes). ZM1702 will report back every time lock and unlock status.
Association group 1 supports 5 nodes.
Command Class | Comment |
---|---|
COMMAND_CLASS_BASIC_V1 | Linked to BASIC |
COMMAND_CLASS_DOOR_LOCK_LOGGING_V1 | |
COMMAND_CLASS_SCHEDULE_ENTRY_LOCK_V2 | |
COMMAND_CLASS_DOOR_LOCK_V1 | |
COMMAND_CLASS_USER_CODE_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_BATTERY_V1 | |
COMMAND_CLASS_ASSOCIATION_V1 | |
COMMAND_CLASS_VERSION_V1 | |
COMMAND_CLASS_TIME_PARAMETERS_V1 | |
COMMAND_CLASS_SECURITY_V1 |
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.