{% include base.html %}

ZM1702 Door Lock with Handle

This describes the Z-Wave device ZM1702, manufactured by Vision Security with the thing type UID of vision_zm1702_00_000.

The device is in the category of Lock, defining Devices whose primary pupose is locking something.

ZM1702 product image

The ZM1702 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.

Overview

The ZM1702 is a Z-Wave controllable, single dead bolt lock. The mechanics can be adopted to right or left opening doors. The door lock can be applied for doors from a thickness of 38 mm and up. The door can be locked and unlocked using the inner side turn piece and/or the key pad. The wireless control allows to lock/unlock the lock, set/unset up to 15 different key codes (4 - 8 key long) and to limit the validity of certain key code.

Inclusion Information

Press Keypads 'C', '8', '8', '8' and manually turn the door lock from inside to be included.

Exclusion Information

Press Keypads 'C', '8', '8', '8' and manually turn the door lock from inside to be excluded.

Channels

The following table summarises the channels available for the ZM1702 -:

Channel Name Channel ID Channel Type Category Item Type
Door Lock lock_door lock_door Door Switch
Battery Level battery-level system.battery_level Battery Number
Entry Alarm alarm_entry alarm_entry Door Switch

Door Lock

Lock and unlock the door.

The lock_door channel is of type lock_door and supports the Switch item and is in the Door category. The following state translation is provided for this channel to the Switch item type -:

Value Label
ON Locked
OFF Unlocked

Battery Level

Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.

The system.battery-level channel is of type system.battery-level and supports the Number item and is in the Battery category. This channel provides the battery level as a percentage and also reflects the low battery warning state. If the battery state is in low battery warning state, this will read 0%.

Entry Alarm

Indicates if the entry alarm is triggered.

The alarm_entry channel is of type alarm_entry and supports the Switch item and is in the Door category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
ON Open
OFF Closed

Device Configuration

The device has no configuration parameters defined.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The ZM1702 supports 1 association group.

Group 1: Report

Target for Door Lock Operation Report commands Support one group (5 nodes). ZM1702 will report back every time lock and unlock status. 

Association group 1 supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_BASIC_V1 Linked to BASIC
COMMAND_CLASS_DOOR_LOCK_LOGGING_V1
COMMAND_CLASS_SCHEDULE_ENTRY_LOCK_V2
COMMAND_CLASS_DOOR_LOCK_V1
COMMAND_CLASS_USER_CODE_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_BATTERY_V1
COMMAND_CLASS_ASSOCIATION_V1
COMMAND_CLASS_VERSION_V1
COMMAND_CLASS_TIME_PARAMETERS_V1
COMMAND_CLASS_SECURITY_V1

Documentation Links