layout | title |
---|---|
documentation |
ZD2105 - ZWave |
{% include base.html %}
This describes the Z-Wave device ZD2105, manufactured by Vision Security with the thing type UID of vision_zd2105_00_000
.
The device is in the category of Door, defining Door sensors.
The ZD2105 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.
The ZD2105 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. Refer to the Wakeup Information section below for further information.
https://fccid.io/KFR-ZD2105US-5
or
http://www.monoprice.com/product?p_id=15268
For “Inclusion” in (adding to) a network: Put the Z-WaveTM Interface Controller into “inclusion” mode, and following its instruction to add the ZD2105 to your controller. To get in the “inclusion” mode, please press the Program Switch of ZD2105 for sending the NIF. After sending NIF, Z-Wave will send the auto inclusion; otherwise, ZD2105 will go to sleep after 20 seconds
For “Exclusion” from (removing from) a network: Put the Z-WaveTM Interface Controller into “exclusion” mode, and following its instruction to delete the ZD2105 from your controller. Press the Program Switch of ZD2105 for 1 second at least to be excluded.
Note: All user and network settings will be cleared and the device reset to factory
The ZD2105 does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour.
The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
Awake Mode:
It will be triggering after opening the cover, also the red LED will keep on lasting 10 seconds and ZD2105 will send “Wake Up Notification” after 10 seconds. If ZD2105 received “Wake Up No More Information” command then the red LED will go off or it will wait 10 seconds then go off. It will proceed all the commands after sending the “Wake Up Notification”
The following table summarises the channels available for the ZD2105 -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Door status | sensor_door | sensor_door | Door | Contact |
Alarm (burglar) | alarm_burglar | alarm_burglar | Door | Switch |
Alarm (access) | alarm_access | alarm_access | Door | Switch |
Battery Level | battery-level | system.battery_level | Battery | Number |
changed to sensor_door for OPEN/CLOSED
Indicates if the door/window is open or closed.
The sensor_door
channel is of type sensor_door
and supports the Contact
item and is in the Door
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Contact
item type -:
Value | Label |
---|---|
OPEN | Open |
CLOSED | Closed |
Indicates if the burglar alarm is triggered.
The alarm_burglar
channel is of type alarm_burglar
and supports the Switch
item and is in the Door
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
Indicates if the access control alarm is triggered.
The alarm_access
channel is of type alarm_access
and supports the Switch
item and is in the Door
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
The system.battery-level
channel is of type system.battery-level
and supports the Number
item and is in the Battery
category.
This channel provides the battery level as a percentage and also reflects the low battery warning state. If the battery state is in low battery warning state, this will read 0%.
The device has no configuration parameters defined.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The ZD2105 supports 1 association group.
Association group 1 supports 5 nodes.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SENSOR_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_ALARM_V3 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1 | |
COMMAND_CLASS_BATTERY_V1 | |
COMMAND_CLASS_WAKE_UP_V2 | |
COMMAND_CLASS_ASSOCIATION_V1 | |
COMMAND_CLASS_VERSION_V2 |
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.