layout title
documentation
Zooz Indoor Siren - ZWave

{% include base.html %}

Zooz Indoor Siren ZSE01

This describes the Z-Wave device Zooz Indoor Siren, manufactured by UFairy G.R. Tech with the thing type UID of ufairy_zse01_00_000.

The device is in the category of Siren, defining Siren used by Alarm systems.

Zooz Indoor Siren product image

The Zooz Indoor Siren does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. Refer to the Wakeup Information section below for further information.

Overview

  • Wireless control, notifications, and trigger by other smart home devices (when included to a Z-Wave gateway controller)
  • Works with micro USB power supply (and 4 AAA batteries as BACK-UP power ONLY, batteries NOT included)
  • Z-Wave Plus certified product: ZC10-16045044. Improved 500 chip for faster and safer wireless communication.
  • Acts as signal repeater when powered by AC adapter
  • Works great with most of the Z-Wave systems supporting simple on/off switch commands (including ADT PULSE)

Inclusion Information

  1. Bring the siren within 3 feet from your Z-Wave gateway controller
  2. Put your Z-Wave controller in inclusion/pairing mode
  3. Press and release the Z-Wave button on the siren THREE TIMES quickly
  4. A new alarm device should appear on your controller’s device list

Q: I have not been able to add the device to my network after several attempts, what do I do now?

A: If you are unable to include the Z-Wave switch to your controller, please try one of the following:

  • Bring the siren closer to your Z-Wave controller
  • Press and release the Z-Wave button quickly several times once you put the controller in the inclusion mode to ensure the command has gone through
  • Put your controller in the EXCLUSION mode and press and release the Z-Wave button quickly 3 times, then try adding it to your network again

Exclusion Information

  1. Bring the siren within 3 feet from your Z-Wave gateway controller
  2. Put your Z-Wave controller in exclusion/unpairing mode
  3. Press and release the Z-Wave button on the siren THREE TIMES quickly
  4. The device should disappear from your controller’s device list Please repeat the process following all steps carefully if first attempt is unsuccessful.

Wakeup Information

The Zooz Indoor Siren does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour.

The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.

Channels

The following table summarises the channels available for the Zooz Indoor Siren -:

Channel Name Channel ID Channel Type Category Item Type
Switch switch_binary switch_binary Switch Switch

Switch

Switch the power on and off.

The switch_binary channel is of type switch_binary and supports the Switch item and is in the Switch category.

Device Configuration

The device has no configuration parameters defined.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The Zooz Indoor Siren supports 1 association group.

Group 1: Lifeline

The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation.

Association group 1 supports 1 node.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC
COMMAND_CLASS_SWITCH_ALL_V1
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_VERSION_V2

Documentation Links


Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.