This describes the Z-Wave device TP-807ZG, manufactured by UFairy G.R. Tech with the thing type UID of ufairy_tp807zg_00_000
.
The device is in the category of Sensor, defining Device used to measure something.
The TP-807ZG does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. Refer to the Wakeup Information section below for further information.
Smoke / Carbon Monoxide / Natural Liquefied Gas Leak Detector
press the button 3 times quickly
press the button 3 times quickly
The TP-807ZG does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour.
The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
The following table summarises the channels available for the TP-807ZG -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Binary Sensor | sensor_binary | sensor_binary | Switch | |
Alarm (CO) | alarm_co | alarm_co | Switch |
Indicates if a sensor has triggered.
The sensor_binary
channel is of type sensor_binary
and supports the Switch
item. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
ON | Triggered |
OFF | Untriggered |
Indicates if the carbon monoxide alarm is triggered.
The alarm_co
channel is of type alarm_co
and supports the Switch
item. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
The device has no configuration parameters defined.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The device does not support associations.
Command Class | Comment |
---|---|
COMMAND_CLASS_SENSOR_BINARY_V1 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_ALARM_V4 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V2 |