XL624 Touchscreen Comfort Control Thermostat

This describes the Z-Wave device XL624, manufactured by Trane Corporation with the thing type UID of trane_xl624_00_000.

The device is in the category of HVAC, defining Air condition devices, Fans.

XL624 product image

The XL624 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

The Trane 624 Touchscreen Comfort Control is compatible with single and multistage forced air systems, including:

  • Gas furnace systems
  • Oil furnace systems
  • Electric furnace systems
  • Heat pump systems
  • Air conditioning systems

Inclusion Information

  1. Press MENU on the 624 Control.
  2. Press NEXT to advance to the Z-WAVE menu.
  3. Press SELECT

Exclusion Information

  1. Press MENU on the 624 Control.
  2. Press NEXT to scroll to Z-WAVE screen then press SELECT.
  3. Press YES to exclude the control

Channels

The following table summarises the channels available for the XL624 -:

Channel Name Channel ID Channel Type Category Item Type
Sensor (relative humidity) sensor_relhumidity sensor_relhumidity Humidity Number
Sensor (temperature) sensor_temperature sensor_temperature Temperature Number:Temperature
Sensor (general) sensor_general sensor_general Number
Thermostat mode thermostat_mode thermostat_mode Temperature Number
Setpoint (cooling) thermostat_setpoint thermostat_setpoint Heating Number:Temperature
Setpoint (heating) thermostat_setpoint thermostat_setpoint Heating Number:Temperature
Thermostat fan mode thermostat_fanmode thermostat_fanmode
Thermostat fan state thermostat_fanstate thermostat_fanstate

Sensor (relative humidity)

Indicates the current relative humidity.

The sensor_relhumidity channel is of type sensor_relhumidity and supports the Number item and is in the Humidity category. This is a read only channel so will only be updated following state changes from the device.

Sensor (temperature)

Indicates the current temperature.

The sensor_temperature channel is of type sensor_temperature and supports the Number:Temperature item and is in the Temperature category.

Sensor (general)

The sensor_general channel is of type sensor_general and supports the Number item. This is a read only channel so will only be updated following state changes from the device.

Thermostat mode

Sets the thermostat.

The thermostat_mode channel is of type thermostat_mode and supports the Number item and is in the Temperature category. The following state translation is provided for this channel to the Number item type -:

Value Label
0 Off
1 Heat
2 Cool
3 Auto
4 Aux Heat
5 Resume
6 Fan Only
7 Furnace
8 Dry Air
9 Moist Air
10 Auto Changeover
11 Heat Economy
12 Cool Economy
13 Away

Setpoint (cooling)

Sets the thermostat setpoint.

The thermostat_setpoint channel is of type thermostat_setpoint and supports the Number:Temperature item and is in the Heating category.

Setpoint (heating)

Sets the thermostat setpoint.

The thermostat_setpoint channel is of type thermostat_setpoint and supports the Number:Temperature item and is in the Heating category.

Thermostat fan mode

Channel type information on this channel is not found.

Thermostat fan state

Channel type information on this channel is not found.

Device Configuration

The following table provides a summary of the 4 configuration parameters available in the XL624. Detailed information on each parameter can be found in the sections below.

Param Name Description
10 Minimum Off Time Minimum Off Time
11 Minimum Run Time Minimum Run Time
12 Heating Delta Stage 1 ON Heating Delta Stage 1 ON
13 Heating Delta Stage 1 OFF Heating Delta Stage 1 OFF

Parameter 10: Minimum Off Time

Minimum Off Time Sets the minimum off time before another heating/cooling cycle can begin to provide compressor short cycle protection. The thermostat screen will display WAIT when minimum off time is being enforced.This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 5 to 9 may be set.

The manufacturer defined default value is 5.

This parameter has the configuration ID config_10_1 and is of type INTEGER.

Parameter 11: Minimum Run Time

Minimum Run Time Sets the minimum run time before a heating/cooling cycle can turn off to prevent rapid cycling. Thermostat screen will display "Cool ON" or "Heat ON" while the minimum run time is being enforced.This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 1 to 9 may be set.

The manufacturer defined default value is 6.

This parameter has the configuration ID config_11_1 and is of type INTEGER.

Parameter 12: Heating Delta Stage 1 ON

Heating Delta Stage 1 ON Sets the delta from setpoint that stage 1 heating starts.This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 1 to 8 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_12_1 and is of type INTEGER.

Parameter 13: Heating Delta Stage 1 OFF

Heating Delta Stage 1 OFF Sets the delta from setpoint that stage 1 heating stops. Stage 1 turns off at setpoint minus (-) Delta Stage 1.This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 8 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_13_1 and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The device does not support associations.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SCENE_ACTIVATION_V1
COMMAND_CLASS_SENSOR_MULTILEVEL_V5
COMMAND_CLASS_THERMOSTAT_MODE_V1
COMMAND_CLASS_THERMOSTAT_OPERATING_STATE_V2
COMMAND_CLASS_THERMOSTAT_SETPOINT_V2
COMMAND_CLASS_THERMOSTAT_FAN_MODE_V2
COMMAND_CLASS_THERMOSTAT_FAN_STATE_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_ASSOCIATION_V1
COMMAND_CLASS_VERSION_V1
COMMAND_CLASS_MULTI_CMD_V1