Heatit Z-TRM 2 Floor thermostat

This describes the Z-Wave device Heatit Z-TRM 2, manufactured by ThermoFloor with the thing type UID of thermofloor_ztrm2_02_006. This version of the device is limited to firmware versions 2.6 to 2.255

The device is in the category of HVAC, defining Air condition devices, Fans.

Heatit Z-TRM 2 product image

The Heatit Z-TRM 2 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

FEATURES

  • Floor sensor
  • Built-in room sensor
  • External room sensor
  • Temperature limiter
  • Weekly program/setback via gateway or pilot wire
  • Multilevel sensor command class
  • Firmware updates (OTA)
  • Power metering
  • LED-diode
  • Can be used in connection with different NTC-sensors
  • Lock mode/child lock
  • Calibration
  • 8 associations
  • Supports encryption mode: S0, S2 Authenticated Class, S2 Unauthenticated Class

Inclusion Information

To include the thermostat to your home automation gateway, press Center (confirm) for 10 seconds.

The display will show OFF. Press Right (down) 4 times till you see Con in the display.

Now start add device in your home automation software.

Start inclusion mode by pressing Center (confirm) for approximately 2 seconds.

Adding mode is indicated in the display by some 'circling' LED segments in the display until the timeout occurs after 20 seconds or the module has been added in the network.

Confirmation will show Inc in the display. If inclusion fails, Err (error) will appear.

Leave programming mode by choosing ESC in the menu.

Your thermostat is ready for use with default settings.

Exclusion Information

To exclude the thermostat to your home automation gateway, press Center (confirm) for 10 seconds.

The display will show OFF. Press Right (down) 4 times till you see Con in the display.

Now start excluding device in your home automation software.

Start exclusion mode by pressing Center (confirm) for approximately 2 seconds.

Adding mode is indicated in the display by some 'circling' LED segments in the display until the timeout occurs after 20 seconds or the module has been excluded from the network.

Confirmation will show Ecl in the display. If exclusion fails, Err (error) will appear.

Leave programming mode by choosing ESC in the menu.

Channels

The following table summarises the channels available for the Heatit Z-TRM 2 -:

Channel Name Channel ID Channel Type Category Item Type
Switch switch_binary switch_binary Switch Switch
Electric meter (volts) meter_voltage meter_voltage Energy Number
Electric meter (watts) meter_watts meter_watts Energy Number
Electric meter (kWh) meter_kwh meter_kwh Energy Number
Thermostat mode thermostat_mode thermostat_mode Temperature Number
Setpoint (furnace) thermostat_setpoint thermostat_setpoint Heating Number:Temperature
Setpoint (heating) thermostat_setpoint thermostat_setpoint Heating Number:Temperature
Setpoint (cooling) thermostat_setpoint thermostat_setpoint Heating Number:Temperature
P Setting config_decimal config_decimal Number
Display brightness config_decimal config_decimal Number
Energy saving mode setpoint config_decimal config_decimal Number
Switch 1 switch_binary1 switch_binary Switch Switch
Electric meter (volts) 1 meter_voltage1 meter_voltage Energy Number
Electric meter (watts) 1 meter_watts1 meter_watts Energy Number
Electric meter (kWh) 1 meter_kwh1 meter_kwh Energy Number
External sensor sensor_temperature2 sensor_temperature Temperature Number:Temperature
Floor sensor sensor_temperature3 sensor_temperature Temperature Number:Temperature
Sensor (temperature) 4 sensor_temperature4 sensor_temperature Temperature Number:Temperature

Switch

Switch the power on and off.

The switch_binary channel is of type switch_binary and supports the Switch item and is in the Switch category.

Electric meter (volts)

Indicates the instantaneous voltage.

The meter_voltage channel is of type meter_voltage and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (watts)

Indicates the instantaneous power consumption.

The meter_watts channel is of type meter_watts and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (kWh)

Indicates the energy consumption (kWh).

The meter_kwh channel is of type meter_kwh and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Thermostat mode

Sets the thermostat.

The thermostat_mode channel is of type thermostat_mode and supports the Number item and is in the Temperature category. The following state translation is provided for this channel to the Number item type -:

Value Label
0 Off
1 Heat
2 Cool
3 Auto
4 Aux Heat
5 Resume
6 Fan Only
7 Furnace
8 Dry Air
9 Moist Air
10 Auto Changeover
11 Heat Economy
12 Cool Economy
13 Away

Setpoint (furnace)

Sets the thermostat setpoint.

The thermostat_setpoint channel is of type thermostat_setpoint and supports the Number:Temperature item and is in the Heating category.

Setpoint (heating)

Sets the thermostat setpoint.

The thermostat_setpoint channel is of type thermostat_setpoint and supports the Number:Temperature item and is in the Heating category.

Setpoint (cooling)

Sets the thermostat setpoint.

The thermostat_setpoint channel is of type thermostat_setpoint and supports the Number:Temperature item and is in the Heating category.

P Setting

Generic class for configuration parameter.

The config_decimal channel is of type config_decimal and supports the Number item.

Display brightness

Generic class for configuration parameter.

The config_decimal channel is of type config_decimal and supports the Number item.

Energy saving mode setpoint

Generic class for configuration parameter.

The config_decimal channel is of type config_decimal and supports the Number item.

Switch 1

Switch the power on and off.

The switch_binary1 channel is of type switch_binary and supports the Switch item and is in the Switch category.

Electric meter (volts) 1

Indicates the instantaneous voltage.

The meter_voltage1 channel is of type meter_voltage and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (watts) 1

Indicates the instantaneous power consumption.

The meter_watts1 channel is of type meter_watts and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (kWh) 1

Indicates the energy consumption (kWh).

The meter_kwh1 channel is of type meter_kwh and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

External sensor

Indicates the current temperature.

The sensor_temperature2 channel is of type sensor_temperature and supports the Number:Temperature item and is in the Temperature category.

Floor sensor

Indicates the current temperature.

The sensor_temperature3 channel is of type sensor_temperature and supports the Number:Temperature item and is in the Temperature category.

Sensor (temperature) 4

Indicates the current temperature.

The sensor_temperature4 channel is of type sensor_temperature and supports the Number:Temperature item and is in the Temperature category.

Device Configuration

The following table provides a summary of the 25 configuration parameters available in the Heatit Z-TRM 2. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Operation mode Operation mode
2 Sensor mode Sensor mode
3 Floor sensor type Floor sensor type
4 Temperature control hysteresis (DIFF I) Temperature control hysteresis (DIFF I)
5 Floor minimum temperature limit (FLo) Floor minimum temperature limit (FLo)
6 Floor maximum temperature (FHi) Floor maximum temperature (FHi)
7 Air minimum temperature limit (ALo) Air minimum temperature limit (ALo)
8 Air maximum temperature limit (AHi) Air maximum temperature limit (AHi)
9 FP mode P setting (PLo) FP mode P setting (PLo)
10 Heating mode setpoint (CO) Heating mode setpoint (CO)
11 Energy saving mode setpoint (ECO) Energy saving mode setpoint (ECO)
12 P setting P setting
13 Cooling setpoint (COOL) Cooling setpoint (COOL)
14 Room sensor calibration Room sensor calibration
15 Floor sensor calibration Floor sensor calibration
16 External sensor calibration External sensor calibration
17 Temperature display Temperature display
18 Button brightness - dimmed state Button brightness - dimmed state
19 Button brightness - active state Button brightness - active state
20 Display brightness - dimmed state Display brightness - dimmed state
21 Display brightness - active state Display brightness - active state
22 Temperature report interval Temperature report interval
23 Temperature report hysteresis Temperature report hysteresis
24 Meter report interval Meter report interval
25 Meter report delta value Meter report delta value

Parameter 1: Operation mode

Operation mode Value = 0, Off (default)
Value = 1, Heating mode
Value = 2, Cooling mode (not implemented)
Value = 11, Energy saving mode The following option values may be configured -:

Value Description
0 Off. (default)
1 Heating mode
2 Cooling mode (not implemented)
11 Energy saving heating mode

The manufacturer defined default value is 0 (Off. (default)).

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Parameter 2: Sensor mode

Sensor mode Value = 0, F-mode, floor sensor mode
Value = 1, A-mode, internal room sensor mode (default)
Value = 2, AF-mode, internal sensor and floor sensor mode
Value = 3, A2-mode, external room sensor mode
Value = 4, P-mode, power regulator mode
Value = 5, FP-mode, floor sensor and power regulator mode The following option values may be configured -:

Value Description
0 F-mode, floor sensor mode
1 A-mode, internal room sensor mode (default)
2 AF-mode, internal sensor and floor sensor mode
3 A2-mode, external room sensor mode
4 P-mode, power regulator mode
5 FP-mode, floor sensor and power regulator mode

The manufacturer defined default value is 1 (A-mode, internal room sensor mode (default)).

This parameter has the configuration ID config_2_1 and is of type INTEGER.

Parameter 3: Floor sensor type

Floor sensor type

  1. Value = 0, 10K-NTC (default)
  2. Value = 1, 12K-NTC
  3. Value = 2, 15K-NTC
  4. Value = 3, 22K-NTC
  5. Value = 4, 33K-NTC
  6. Value = 5, 47K-NTC The following option values may be configured -:
Value Description
0 10K-NTC (default)
1 12K-NTC
2 15K-NTC
3 22K-NTC
4 33K-NTC
5 47K-NTC

The manufacturer defined default value is 0 (10K-NTC (default)).

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Parameter 4: Temperature control hysteresis (DIFF I)

Temperature control hysteresis (DIFF I)

  1. Value = 0 - 30, 0.3C - 3.0C (default is 0.5C)
    When using a water-based heating, the recommended hysteresis is a minimum of 1.0C Values in the range 0 to 30 may be set.

The manufacturer defined default value is 5.

This parameter has the configuration ID config_4_1 and is of type INTEGER.

Parameter 5: Floor minimum temperature limit (FLo)

Floor minimum temperature limit (FLo)

  1. Value = 50 - 400, 5.0C - 40.0C, default = 5.0C Values in the range 50 to 400 may be set.

The manufacturer defined default value is 50.

This parameter has the configuration ID config_5_2 and is of type INTEGER.

Parameter 6: Floor maximum temperature (FHi)

Floor maximum temperature (FHi)

  1. Value = 50 - 400, 5.0C - 40.0C, default = 40.0C) Values in the range 50 to 400 may be set.

The manufacturer defined default value is 400.

This parameter has the configuration ID config_6_2 and is of type INTEGER.

Parameter 7: Air minimum temperature limit (ALo)

Air minimum temperature limit (ALo)

  1. Value = 50 - 400, 5.0C - 40.0C, default = 5.0C Values in the range 50 to 400 may be set.

The manufacturer defined default value is 50.

This parameter has the configuration ID config_7_2 and is of type INTEGER.

Parameter 8: Air maximum temperature limit (AHi)

Air maximum temperature limit (AHi)

  1. Value = 50 - 400, 5.0C - 40.0C, default = 40.0C) Values in the range 50 to 400 may be set.

The manufacturer defined default value is 400.

This parameter has the configuration ID config_8_2 and is of type INTEGER.

Parameter 9: FP mode P setting (PLo)

FP mode P setting (PLo)

  1. Value = 0 - 9, default = 0 Values in the range 0 to 9 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_9_1 and is of type INTEGER.

Parameter 10: Heating mode setpoint (CO)

Heating mode setpoint (CO)

  1. Value = 50 - 400, 5.0C - 40.0C, default = 21.0C Values in the range 50 to 400 may be set.

The manufacturer defined default value is 210.

This parameter has the configuration ID config_10_2 and is of type INTEGER.

Parameter 11: Energy saving mode setpoint (ECO)

Energy saving mode setpoint (ECO)

  1. Value = 50 - 400, 5.0C - 40.0C, default = 18.0C Values in the range 50 to 400 may be set.

The manufacturer defined default value is 180.

This parameter has the configuration ID config_11_2 and is of type INTEGER.

Parameter 12: P setting

P setting

  1. Value = 0 - 10, default = 2 Values in the range 0 to 10 may be set.

The manufacturer defined default value is 2.

This parameter has the configuration ID config_12_1 and is of type INTEGER.

Parameter 13: Cooling setpoint (COOL)

Cooling setpoint (COOL)

  1. Value = 50 - 400, 5.0C - 40.0C, default = 21.0C Values in the range 50 to 400 may be set.

The manufacturer defined default value is 210.

This parameter has the configuration ID config_13_2 and is of type INTEGER.

Parameter 14: Room sensor calibration

Room sensor calibration

  1. Value = -40 - 40, -4.0V - 4.0C, default = 0.0C Values in the range -40 to 40 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_14_1 and is of type INTEGER.

Parameter 15: Floor sensor calibration

Floor sensor calibration

  1. Value = -40 - 40, -4.0C - 4.0C, default = 0.0C Values in the range -40 to 40 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_15_1 and is of type INTEGER.

Parameter 16: External sensor calibration

External sensor calibration

  1. Value = -40 - 40, -4.0C - 4.0C, default = 0.0C Values in the range -40 to 40 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_16_1 and is of type INTEGER.

Parameter 17: Temperature display

Temperature display

  1. Value = 0, Display setpoint temperature (default)
  2. Value = 1, Display calculated temperature The following option values may be configured -:
Value Description
0 Display setpoint temperature (default)
1 Display calculated temperature

The manufacturer defined default value is 0 (Display setpoint temperature (default)).

This parameter has the configuration ID config_17_1 and is of type INTEGER.

Parameter 18: Button brightness - dimmed state

Button brightness - dimmed state

  1. Value = 0 - 100, 0% - 100%, default = 50% Values in the range 0 to 100 may be set.

The manufacturer defined default value is 50.

This parameter has the configuration ID config_18_1 and is of type INTEGER.

Parameter 19: Button brightness - active state

Button brightness - active state

  1. Value = 0 - 100, 0% - 100%, default = 100% Values in the range 0 to 100 may be set.

The manufacturer defined default value is 100.

This parameter has the configuration ID config_19_1 and is of type INTEGER.

Parameter 20: Display brightness - dimmed state

Display brightness - dimmed state

  1. Value = 0 - 100, 0% - 100%, default = 50% Values in the range 0 to 100 may be set.

The manufacturer defined default value is 50.

This parameter has the configuration ID config_20_1 and is of type INTEGER.

Parameter 21: Display brightness - active state

Display brightness - active state

  1. Value = 0 - 100, 0% - 100%, default = 100% Values in the range 0 to 100 may be set.

The manufacturer defined default value is 100.

This parameter has the configuration ID config_21_1 and is of type INTEGER.

Parameter 22: Temperature report interval

Temperature report interval

  1. Value = 0, Reporting of temperature disabled
  2. Value = 1 - 32767, 1s - 32767s, default = 60s

Time interval between consecutive temperature reports.
Temperature reports can also be sent as a result of polling. Values in the range 0 to 32767 may be set.

The manufacturer defined default value is 60.

This parameter has the configuration ID config_22_2 and is of type INTEGER.

Parameter 23: Temperature report hysteresis

Temperature report hysteresis

  1. Value = 1 - 100, 0.1C - 10.0C, default = 1.0C

The temperature report will be sent if there is a difference in temperature from the previous value reported,
defined in this parameter (hysteresis).
Temperature reports can also be sent as a result of polling. Values in the range 1 to 100 may be set.

The manufacturer defined default value is 10.

This parameter has the configuration ID config_23_1 and is of type INTEGER.

Parameter 24: Meter report interval

Meter report interval

  1. Value = 0, Reporting of metering values is disabled
  2. Value = 1 - 32767, 1s - 32767s, default = 60s

Time interval between consecutive meter reports.
Meter reports can also be sent as a result of polling. Values in the range 0 to 32767 may be set.

The manufacturer defined default value is 60.

This parameter has the configuration ID config_24_2 and is of type INTEGER.

Parameter 25: Meter report delta value

Meter report delta value

  1. Value = 0 - 255, 0kWh - 25.5kWh, default = 1.0kWh

Delta value in kWh between consecutive meter reports.
Meter reports can also be sent as a result of polling. Values in the range 0 to 255 may be set.

The manufacturer defined default value is 10.

This parameter has the configuration ID config_25_1 and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The Heatit Z-TRM 2 supports 5 association groups.

Group 1: Lifeline

The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. Lifeline. (Normally used by the Z-Wave Controller)
Sends:

  • Device Reset Notifications
  • Thermostat Setpoint Reports
  • Thermostat Mode Reports

Association group 1 supports 7 nodes.

Group 2: Thermostat Binary Switch Set

Send Binary Switch Set commands representing the status of the internal relay.

Association group 2 supports 7 nodes.

Group 3: Thermostat Internal Multilevel Sensor Reports

Send Multilevel Sensor Reports for internal temperature sensor.

Association group 3 supports 7 nodes.

Group 4: Thermostat External Multilevel Sensor Reports

Send Multilevel Sensor Reports for external temperature sensor.

Association group 4 supports 7 nodes.

Group 5: Thermostat Floor Multilevel Sensor Reports

Send Multilevel Sensor Reports for floor temperature sensor.

Association group 5 supports 7 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1
COMMAND_CLASS_METER_V3
COMMAND_CLASS_THERMOSTAT_MODE_V1
COMMAND_CLASS_THERMOSTAT_SETPOINT_V1
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_MULTI_CHANNEL_V2
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_VERSION_V2
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3
COMMAND_CLASS_SECURITY_V1

Endpoint 1

Command Class Comment
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1
COMMAND_CLASS_METER_V3
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3

Endpoint 2

Command Class Comment
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SENSOR_MULTILEVEL_V1
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3

Endpoint 3

Command Class Comment
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SENSOR_MULTILEVEL_V1
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3

Endpoint 4

Command Class Comment
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SENSOR_MULTILEVEL_V1
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3

Documentation Links


Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.