layout | title |
---|---|
documentation |
TZWP-100 - ZWave |
{% include base.html %}
This describes the Z-Wave device TZWP-100, manufactured by Telldus Technologies AB with the thing type UID of telldus_tzwp100_00_000
.
The device is in the category of Power Outlet, defining Small devices to be plugged into a power socket in a wall which stick there.
The TZWP-100 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
Plugin switch, controls lighting and other electronic equipment up to 2000 W (resistive load).
Press the button on the device three times fast.
Press the button on the device three times fast.
The following table summarises the channels available for the TZWP-100 -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Switch | switch_binary | switch_binary | Switch | Switch |
Switch the power on and off.
The switch_binary
channel is of type switch_binary
and supports the Switch
item and is in the Switch
category.
The following table provides a summary of the 3 configuration parameters available in the TZWP-100. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Countdown timer | Automatic turning off in minutes, 0 to disable |
2 | Device status after power failure | Define how the plug will react after the power supply is back on |
3 | LED indicator | Set the intensity of the LED indicator |
Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands |
Automatic turning off in minutes, 0 to disable
Values in the range 0 to 254 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
Define how the plug will react after the power supply is back on
The following option values may be configured -:
Value | Description |
---|---|
0 | Always off |
1 | Remember status |
2 | Always on |
The manufacturer defined default value is 1
(Remember status).
This parameter has the configuration ID config_2_1
and is of type INTEGER
.
Set the intensity of the LED indicator
Values in the range 0 to 100 may be set.
The manufacturer defined default value is 100
.
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
Set the mode for the switch when receiving SWITCH ALL commands.
The following option values may be configured -:
Value | Description |
---|---|
0 | Exclude from All On and All Off groups |
1 | Include in All On group |
2 | Include in All Off group |
255 | Include in All On and All Off groups |
This parameter has the configuration ID switchall_mode
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The TZWP-100 supports 2 association groups.
The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation.
The plug will send it's status to the node in this group whenever the status of the plug changes.
Lifeline is normally used to send the plug status to the main controller / gateway.
Association group 1 supports 1 node.
The plug will send Basic Set control signals to the nodes in this group whenever the status of the
plug changes. This will work like a master/slave solution.
Association group 2 supports 10 nodes.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_SWITCH_ALL_V1 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_PROTECTION_V2 | |
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1 | |
COMMAND_CLASS_ASSOCIATION_V1 | |
COMMAND_CLASS_VERSION_V1 |
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.