TZWP-100 - ZWave

{% include base.html %}

TZWP-100 Wall Plug Switch

This describes the Z-Wave device TZWP-100, manufactured by Telldus Technologies AB with the thing type UID of telldus_tzwp100_00_000.

The device is in the category of Power Outlet, defining Small devices to be plugged into a power socket in a wall which stick there.

TZWP-100 product image

The TZWP-100 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

Plug­in switch, controls lighting and other electronic equipment up to 2000 W (resistive load).

Inclusion Information

Press the button on the device three times fast.

Exclusion Information

Press the button on the device three times fast.

Channels

The following table summarises the channels available for the TZWP-100 -:

Channel Name Channel ID Channel Type Category Item Type
Switch switch_binary switch_binary Switch Switch

Switch

Switch the power on and off.

The switch_binary channel is of type switch_binary and supports the Switch item and is in the Switch category.

Device Configuration

The following table provides a summary of the 3 configuration parameters available in the TZWP-100. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Countdown timer Automatic turning off in minutes, 0 to disable
2 Device status after power failure Define how the plug will react after the power supply is back on
3 LED indicator Set the intensity of the LED indicator
Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Parameter 1: Countdown timer

Automatic turning off in minutes, 0 to disable

Values in the range 0 to 254 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Parameter 2: Device status after power failure

Define how the plug will react after the power supply is back on

The following option values may be configured -:

Value Description
0 Always off
1 Remember status
2 Always on

The manufacturer defined default value is 1 (Remember status).

This parameter has the configuration ID config_2_1 and is of type INTEGER.

Parameter 3: LED indicator

Set the intensity of the LED indicator

Values in the range 0 to 100 may be set.

The manufacturer defined default value is 100.

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -:

Value Description
0 Exclude from All On and All Off groups
1 Include in All On group
2 Include in All Off group
255 Include in All On and All Off groups

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The TZWP-100 supports 2 association groups.

Group 1: Lifeline

The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. The plug will send it's status to the node in this group whenever the status of the plug changes.
Lifeline is normally used to send the plug status to the main controller / gateway.

Association group 1 supports 1 node.

Group 2: Control other devices

The plug will send Basic Set control signals to the nodes in this group whenever the status of the
plug changes. This will work like a master/slave solution.

Association group 2 supports 10 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC
COMMAND_CLASS_SWITCH_ALL_V1
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_PROTECTION_V2
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1
COMMAND_CLASS_ASSOCIATION_V1
COMMAND_CLASS_VERSION_V1

Documentation Links