This describes the Z-Wave device ZV9001K8-DIM, manufactured by Sunricher with the thing type UID of sunricher_zv9001k8dim_00_000.

The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.

ZV9001K8-DIM product image

The ZV9001K8-DIM supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.

The ZV9001K8-DIM does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. Refer to the Wakeup Information section below for further information.

Overview

The SR-ZV9001K8-DIM is a new single color wall mounted push button z-wave secondary controller light switch which adopts latest z-wave RF Plus and Mesh network technology to switch and dim single color LED lighting. It is a universal z-wave slave and can be added to z-wave network or removed from z-wave network by z-wave primary (master) or gateway.

The wall controller is powered by a cell lithium battery. The wireless dimmer is compatible with single color z wave device SR-ZV9101FA-DIM and different frequencies are available for different countries or areas. The signal transmit distance can be up to 30m.

It supports 5 groups for associations, a lifeline group association to primary (master) controller and 4 groups association to devices, the groups association to devices support maximum 20 Z-wave devices per group. Compatible with existing frames from Berker, Gira, Jung and Merten, the z-wave secondary controller is easy to be mounted on the wall.

Key Features

  • Z-wave secondary controller light switch
  • Source-routed Mesh Network Architecture
  • Each device works as a node
  • All Nodes Are Transceivers
  • Each Z-wave Network Allows Up to 243 Devices
  • Actively route around and circumvent obstacles or radio dead spots
  • Wireless Synchronization to Drastically Increase Control Distance
  • Devices can communicate to one another by using intermediate nodes
  • Added to z-wave network by z-wave masters or gateway
  • Removed from z-wave network by z-wave masters or gateway
  • Compatible with universal z-wave masters/gateway
  • Supports 1 lifeline group association to master controller
  • Supports 4 groups association to z-wave devices, maximum 20 devices per group

Inclusion Information

Please make sure the battery of the wall mounted controller has enough power (press any key and if the blue LED indicator turns on, which means the remote works well) -> set the master controller or gateway into network inclusion or add device mode (please refer to the user manual to learn how) -> press and hold down both keys I and O at the top row (group 2) simultaneously on the wall controller until LED indicator turns on and flashes 6 times quickly to indicate successful adding -> there shall be an indication on the master controller or gateway.

Exclusion Information

When the wall mounted controller has already been added to z-wave network, set z-wave master (primary) controller or z-wave gateway into network inclusion or remove device mode (please refer to the user manual to learn how) -> press and hold down both keys I and O at the top row (group 2) simultaneously on the wall controller until LED indicator turns on and shows 3 short blinks and 1 long blink to indicate successful removing -> there shall be an indication on the master controller or gateway.

Wakeup Information

The ZV9001K8-DIM does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour.

The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.

Channels

The following table summarises the channels available for the ZV9001K8-DIM -:

Channel Name Channel ID Channel Type Category Item Type
switch_binary switch_binary switch_binary Switch Switch
switch_dimmer switch_dimmer switch_dimmer DimmableLight Dimmer
Scene Number scene_number scene_number Number
Battery Level battery-level system.battery_level Battery Number
Switch 1 switch_binary1 switch_binary Switch Switch
Switch 2 switch_binary2 switch_binary Switch Switch
Switch 3 switch_binary3 switch_binary Switch Switch

switch_binary

Switch the power on and off.

The switch_binary channel is of type switch_binary and supports the Switch item and is in the Switch category.

switch_dimmer

The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.

The switch_dimmer channel is of type switch_dimmer and supports the Dimmer item and is in the DimmableLight category.

Scene Number

Triggers when a scene button is pressed.

The scene_number channel is of type scene_number and supports the Number item. This channel provides the scene, and the event as a decimal value in the form <scene>.<event>. The scene number is set by the device, and the event is as follows -:

Event ID Event Description
0 Single key press
1 Key released
2 Key held down
3 Double keypress
4 Tripple keypress
5 4 x keypress
6 5 x keypress

Battery Level

Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.

The system.battery-level channel is of type system.battery-level and supports the Number item and is in the Battery category. This channel provides the battery level as a percentage and also reflects the low battery warning state. If the battery state is in low battery warning state, this will read 0%.

Switch 1

Switch the power on and off.

The switch_binary1 channel is of type switch_binary and supports the Switch item and is in the Switch category.

Switch 2

Switch the power on and off.

The switch_binary2 channel is of type switch_binary and supports the Switch item and is in the Switch category.

Switch 3

Switch the power on and off.

The switch_binary3 channel is of type switch_binary and supports the Switch item and is in the Switch category.

Device Configuration

The device has no configuration parameters defined.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The ZV9001K8-DIM supports 5 association groups.

Group 1: Lifeline

The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. Send Mode: Single Cast

Send Commands:

  • DEVICE_RESET_LOCALLY_NOTIFICATION
  • BATTERY_REPORT

Association group 1 supports 1 node.

Group 2: Launch 1

Send Mode: Multicast

Send Commands:

  • the Basic Set
  • Switch Multilevel Start Level Change
  • Switch Multilevel Stop Level Change

Association group 2 supports 20 nodes.

Group 3: Launch 2

Send Mode: Multicast

Send Commands:

  • the Basic Set
  • Switch Multilevel Start Level Change
  • Switch Multilevel Stop Level Change

Association group 3 supports 20 nodes.

Group 4: Launch 3

Send Mode: Multicast

Send Commands:

  • the Basic Set
  • Switch Multilevel Start Level Change
  • Switch Multilevel Stop Level Change

Association group 4 supports 20 nodes.

Group 5: Launch 4

Send Mode: Multicast

Send Commands:

  • the Basic Set
  • Switch Multilevel Start Level Change
  • Switch Multilevel Stop Level Change

Association group 5 supports 20 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC
COMMAND_CLASS_SWITCH_MULTILEVEL_V1
COMMAND_CLASS_TRANSPORT_SERVICE_V1
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_CENTRAL_SCENE_V3
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_SUPERVISION_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_BATTERY_V1
COMMAND_CLASS_WAKE_UP_V2
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_VERSION_V2
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3
COMMAND_CLASS_SECURITY_V1
COMMAND_CLASS_SECURITY_2_V1

Endpoint 1

Command Class Comment
COMMAND_CLASS_BASIC_V1 Linked to BASIC

Endpoint 2

Command Class Comment
COMMAND_CLASS_BASIC_V1 Linked to BASIC

Endpoint 3

Command Class Comment
COMMAND_CLASS_BASIC_V1 Linked to BASIC

Documentation Links


Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.