layout | title |
---|---|
documentation |
ZV9001K4-DIM - ZWave |
{% include base.html %}
This describes the Z-Wave device ZV9001K4-DIM, manufactured by Sunricher with the thing type UID of sunricher_zv9001k4dim_00_000
.
The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.
The ZV9001K4-DIM supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.
The ZV9001K4-DIM does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. Refer to the Wakeup Information section below for further information.
The SR-ZV9001K4-DIM is a new single color wall mounted push button z-wave secondary controller light switch which adopts latest z-wave RF Plus and Mesh network technology to switch and dim single color LED lighting. It is a universal z-wave slave and can be added to z-wave network or removed from z-wave network by z-wave primary (master) or gateway.
The wall controller is powered by a cell lithium battery. The wireless dimmer is compatible with single color z wave device SR-ZV9101FA-DIM and different frequencies are available for different countries or areas. The signal transmit distance can be up to 30m.
It supports 3 groups for associations, a lifeline group association to primary (master) controller and 2 groups association to devices, the groups association to devices support maximum 20 Z-wave devices per group. Compatible with existing frames from Berker, Gira, Jung and Merten, the z-wave secondary controller is easy to be mounted on the wall.
Key Features
- Z-wave secondary controller light switch
- Source-routed Mesh Network Architecture
- Each device works as a node
- All Nodes Are Transceivers
- Each Z-wave Network Allows Up to 243 Devices
- Actively route around and circumvent obstacles or radio dead spots
- Wireless Synchronization to Drastically Increase Control Distance
- Devices can communicate to one another by using intermediate nodes
- Added to z-wave network by z-wave masters or gateway
- Removed from z-wave network by z-wave masters or gateway
- Compatible with universal z-wave masters/gateway
- Supports 1 lifeline group association to master controller
- Supports 2 groups association to z-wave devices, maximum 20 devices per group
Please make sure the battery of the wall mounted controller has enough power (press any key and if the blue LED indicator turns on, which means the remote works well) -> set the master controller or gateway into network inclusion or add device mode (please refer to the user manual to learn how) -> press and hold down both keys I and O at the top row (group 2) simultaneously on the wall controller until LED indicator turns on and flashes 6 times quickly to indicate successful adding -> there shall be an indication on the master controller or gateway.
When the wall mounted controller has already been added to z-wave network, set z-wave master (primary) controller or z-wave gateway into network inclusion or remove device mode (please refer to the user manual to learn how) -> press and hold down both keys I and O at the top row (group 2) simultaneously on the wall controller until LED indicator turns on and shows 3 short blinks and 1 long blink to indicate successful removing -> there shall be an indication on the master controller or gateway.
The ZV9001K4-DIM does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour.
The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
Press any button.
The following table summarises the channels available for the ZV9001K4-DIM -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
switch_binary [Deprecated] | switch_binary | switch_binary | Switch | Switch |
switch_dimmer | switch_dimmer | switch_dimmer | DimmableLight | Dimmer |
Scene Number | scene_number | scene_number | Number | |
Battery Level | battery-level | system.battery_level | Battery | Number |
Switch the power on and off.
The switch_binary
channel is of type switch_binary
and supports the Switch
item and is in the Switch
category.
Note: This channel is marked as deprecated so should not be used.
The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.
The switch_dimmer
channel is of type switch_dimmer
and supports the Dimmer
item and is in the DimmableLight
category.
Triggers when a scene button is pressed.
The scene_number
channel is of type scene_number
and supports the Number
item.
This channel provides the scene, and the event as a decimal value in the form <scene>.<event>
. The scene number is set by the device, and the event is as follows -:
Event ID | Event Description |
---|---|
0 | Single key press |
1 | Key released |
2 | Key held down |
3 | Double keypress |
4 | Tripple keypress |
5 | 4 x keypress |
6 | 5 x keypress |
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
The system.battery-level
channel is of type system.battery-level
and supports the Number
item and is in the Battery
category.
This channel provides the battery level as a percentage and also reflects the low battery warning state. If the battery state is in low battery warning state, this will read 0%.
The device has no configuration parameters defined.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The ZV9001K4-DIM supports 3 association groups.
The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. Send Mode: Single Cast
Send Commands:
- DEVICE_RESET_LOCALLY_NOTIFICATION
- BATTERY_REPORT
Association group 1 supports 5 nodes.
Send Mode: Multicast
Send Commands:
- The Basic Set
- Switch Multilevel Start Level Change
- Switch Multilevel Stop Level Change
Association group 2 supports 5 nodes.
Send Mode: Multicast
Send Commands:
- The Basic Set
- Switch Multilevel Start Level Change
- Switch Multilevel Stop Level Change
Association group 3 supports 5 nodes.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_SWITCH_MULTILEVEL_V1 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_CENTRAL_SCENE_V3 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1 | |
COMMAND_CLASS_BATTERY_V1 | |
COMMAND_CLASS_WAKE_UP_V2 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V2 | |
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3 |
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.