This describes the Z-Wave device ZV2835RAC, manufactured by Sunricher with the thing type UID of sunricher_zv2835rac_00_000
.
This version of the device is limited to firmware versions below 1.23
The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.
The ZV2835RAC supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
The knob smart dimmer is a Z-Wave device designed to work with various types of light sources. It may be connected to two-wire or three-wire configuration so it can operate with or without neutral lead. The dimmer can switch or dim connected light source either through Z-Wave devices or through the rotary knob directly. The smart dimmer is equipped with an algorithm of smart light source detection which makes configuration easier and ensures high compatibility of the device. It may be used as a switch with non-dimmable light sources (in 3-wire connection).
Main Features:
- Advanced microprocessor control,
- Implemented algorithm of smart light source detection,
- Auto-adjustment of the appropriate control mode to connected load,
- Active power and energy metering functionality,
- Soft start function,
- Memory of the last lighting level settings
It operates under the following loads:
- Conventional incandescent and HV halogen light sources
- ELV halogen lamps and dimmable LED bulbs (with electronic transformers)
- MLV halogen lamps (with ferromagnetic transformers)
- Dimmable LED bulbs
- Dimmable compact fluorescent CFL tube lamps
It can be configured to use “Trailing edge” or “Leading edge” to control following load types:
- "Trailing edge" for resistive loads
- "Trailing edge" for capacitive loads
- "Leading edge" for inductive loa
There are two methods to set the dimmer into inclusion mode:
- Repower on the dimmer, it will be set into inclusion mode automatically, and waiting to be included.
- Triple press reset button on the dimmer, it will set the dimmer into inclusion mode.
There are two exclusion methods:
Method 1: Exclusion from the primary controller/gateway as follows:
- Set the primary controller/gateway into exclusion mode (Please refer to your primary controllers manual on how to set your controller into exclusion).
- Triple press reset button, the dimmer will be set to exclusion mode, and waiting to be excluded, then the dimmer will be excluded from the network.
Method 2: Factory reset the dimmer will force it to be excluded from a network. Note: Factory reset is not recommended for exclusion, please use this procedure only if the primary controller/gateway is missing or otherwise inoperable.
Factory Reset: Press and hold down the reset button for over 10 seconds, the dimmer will be reset to factory defaults, the load brightness will be restored to 50% and will flash slowly.
The following table summarises the channels available for the ZV2835RAC -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Dimmer | switch_dimmer | switch_dimmer | DimmableLight | Dimmer |
Scene Number | scene_number | scene_number | Number | |
Electric meter (volts) | meter_voltage | meter_voltage | Energy | Number |
Electric meter (amps) | meter_current | meter_current | Energy | Number |
Electric meter (kWh) | meter_kwh | meter_kwh | Energy | Number |
Electric meter (watts) | meter_watts | meter_watts | Energy | Number |
Alarm (power) | alarm_power | alarm_power | Energy | Switch |
Alarm (system) | alarm_system | alarm_system | Switch |
The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.
The switch_dimmer
channel is of type switch_dimmer
and supports the Dimmer
item and is in the DimmableLight
category.
Triggers when a scene button is pressed.
The scene_number
channel is of type scene_number
and supports the Number
item.
Indicates the instantaneous voltage.
The meter_voltage
channel is of type meter_voltage
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous current consumption.
The meter_current
channel is of type meter_current
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the energy consumption (kWh).
The meter_kwh
channel is of type meter_kwh
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous power consumption.
The meter_watts
channel is of type meter_watts
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates if a power alarm is triggered.
The alarm_power
channel is of type alarm_power
and supports the Switch
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
Indicates if a system alarm is triggered.
The alarm_system
channel is of type alarm_system
and supports the Switch
item. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
The following table provides a summary of the 20 configuration parameters available in the ZV2835RAC. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
2 | Saving load state | Saving load state before power failure |
3 | Basic report | Send the basic report to the Lifeline when the load state changed |
4 | Default fade time | Default fade time |
5 | Minimum brightness | Minimum brightness |
6 | Maximum brightness | Maximum brightness |
7 | MOSFET driving type | MOSFET driving type |
8 | Step setting | Step setting of the knob |
9 | Add and remove through switch | Add and remove through switch |
10 | Load detection | Load detection |
11 | Wiring type | Wiring type |
12 | Load type | Load type |
13 | Overcurrect Protection | Overcurrect Protection |
14 | Power absolute threshold | Power automatic report absolute threshold |
15 | Power percentage threshold | Power automatic report percentage threshold |
21 | Power report cycle | Power metering automatic report time cycle |
22 | Energy report cycle | Energy metering automatic report time cycle |
23 | Voltage report cycle | Voltage metering automatic report time cycle |
24 | Current report cycle | Current metering automatic report time cycle |
31 | Dimming curve | Dimming Curve |
32 | Startup brightness | Startup brightness |
Saving load state before power failure Info: Saving load state before power failure 0 - shutoff load 1 - turn on load 2 - save load state before power failure The following option values may be configured -:
Value | Description |
---|---|
0 | Shutoff load |
1 | turn on load |
2 | Save load state |
The manufacturer defined default value is 2
(Save load state ).
This parameter has the configuration ID config_2_1
and is of type INTEGER
.
Send the basic report to the Lifeline when the load state changed Info: Enable/disable to send the basic report to the Lifeline when the load state changed(When value set as 1, re-power on the dimmer, it will send Basic report automatically) 0 - Disable to send Basic report 1 - Enable to send Basic report The following option values may be configured -:
Value | Description |
---|---|
0 | Disable Basic report |
1 | Enable Basic report |
The manufacturer defined default value is 1
(Enable Basic report).
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
Default fade time Default fade time (unit is second, this value has the same function as Duration of Multilevel) 0: Instantly 1-127: 1 to 127 seconds in 1 second resolution Values in the range 0 to 127 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_4_1
and is of type INTEGER
.
Minimum brightness
Values in the range 0 to 50 may be set.
The manufacturer defined default value is 15
.
This parameter has the configuration ID config_5_1
and is of type INTEGER
.
Maximum brightness
Values in the range 0 to 100 may be set.
The manufacturer defined default value is 100
.
This parameter has the configuration ID config_6_1
and is of type INTEGER
.
MOSFET driving type MOSFET driving type:
0 - trailing edge
1 - leading edge
The following option values may be configured -:
Value | Description |
---|---|
0 | Trailing edge |
1 | Leading edge |
The manufacturer defined default value is 0
(Trailing edge).
This parameter has the configuration ID config_7_1
and is of type INTEGER
.
Step setting of the knob Setting step of the knob
Corresponding dimming stepping level for each rotation of the knob (a full dimming stepping level is 99) Valid value: 1-50 Values in the range 1 to 50 may be set.
The manufacturer defined default value is 5
.
This parameter has the configuration ID config_8_1
and is of type INTEGER
.
Add and remove through switch Added to and removed from a network through external switch (when enables this function, triple press the external switch within 1.5 seconds to be added to or removed from a network)
0 - disable
1 - enable
The following option values may be configured -:
Value | Description |
---|---|
0 | Disable |
1 | Enable |
The manufacturer defined default value is 0
(Disable).
This parameter has the configuration ID config_9_1
and is of type INTEGER
.
Load detection
Enable/disable to detect load after re-power on (detect load type, minimum brightness, maximum brightness)
0 - disable
1 - enable to detect every time after re-power on
2 - enable to detect only after first re-power on
Note: When the device does not belong to any network, load detection will be enabled every time after re-power on. When the device has already been added to a network, load detection will be disabled. The following option values may be configured -:
Value | Description |
---|---|
0 | Disable |
1 | Enable after each power on |
2 | Enable after first power on |
The manufacturer defined default value is 0
(Disable).
This parameter has the configuration ID config_10_1
and is of type INTEGER
.
Wiring type Wiring type
0 - unknown
1 - 2 Wire With No Neutral
2 - 3 Wire With Neutral
The following option values may be configured -:
Value | Description |
---|---|
0 | Unknown |
1 | 2 Wire with no Neutral |
2 | 3 Wire with Neutral |
The manufacturer defined default value is 0
(Unknown).
This parameter has the configuration ID config_11_1
and is of type INTEGER
.
This is a read only parameter.
Load type Load type
0 - unknown
1 - resistive
2 - inductive
3 - capacitive
The following option values may be configured -:
Value | Description |
---|---|
0 | Unknown |
1 | Resistive |
2 | Inductive |
3 | Capacitive |
The manufacturer defined default value is 0
(Unknown).
This parameter has the configuration ID config_12_1
and is of type INTEGER
.
This is a read only parameter.
Overcurrect Protection Enable/disable over current protection (over 3.2A for 20 seconds continuously)
0 – disable
1 – enable
The following option values may be configured -:
Value | Description |
---|---|
0 | Disable |
1 | Enable |
The manufacturer defined default value is 1
(Enable).
This parameter has the configuration ID config_13_1
and is of type INTEGER
.
Power automatic report absolute threshold
Power automatic report absolute threshold, unit is W
When power changes above the absolute threshold, immediately report current power value
Values in the range 0 to 600 may be set.
The manufacturer defined default value is 10
.
This parameter has the configuration ID config_14_2
and is of type INTEGER
.
Power automatic report percentage threshold
Power automatic report percentage threshold, unit is %
When power changes above the percentage threshold, immediately report current power value
Values in the range 0 to 100 may be set.
The manufacturer defined default value is 20
.
This parameter has the configuration ID config_15_1
and is of type INTEGER
.
Power metering automatic report time cycle
Power metering automatic report time cycle, unit is second
Valid time cycle value: 5~2678400
Default is 600 seconds (10 minutes)
Values in the range 5 to 2678400 may be set.
The manufacturer defined default value is 600
.
This parameter has the configuration ID config_21_4
and is of type INTEGER
.
Energy metering automatic report time cycle Energy metering automatic report time cycle, unit is second
Valid time cycle value: 5~2678400
Default is 1800 seconds (30 minutes) Values in the range 5 to 2678400 may be set.
The manufacturer defined default value is 1800
.
This parameter has the configuration ID config_22_4
and is of type INTEGER
.
Voltage metering automatic report time cycle Voltage metering automatic report time cycle, unit is second
Valid time cycle value: 5~267840 Values in the range 5 to 2678400 may be set.
The manufacturer defined default value is 3600
.
This parameter has the configuration ID config_23_4
and is of type INTEGER
.
Current metering automatic report time cycle Current metering automatic report time cycle, unit is second
Valid time cycle value: 5~2678400 Values in the range 5 to 2678400 may be set.
The manufacturer defined default value is 3600
.
This parameter has the configuration ID config_24_4
and is of type INTEGER
.
Dimming Curve
The following option values may be configured -:
Value | Description |
---|---|
0 | Linear dimming |
1 | Logarithmic dimming |
The manufacturer defined default value is 0
(Linear dimming).
This parameter has the configuration ID config_31_1
and is of type INTEGER
.
Startup brightness Setting startup brightness of the load
Valid value: 0~99
Note: every time when turn on the load from OFF status, if the target brightness is lower than the startup brightness, the brightness will first go to the startup brightness value then fall down to the target brightness Values in the range 0 to 99 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_32_1
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The ZV2835RAC supports 2 association groups.
The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation.
Association group 1 supports 5 nodes.
Association group 2 supports 5 nodes.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_MULTILEVEL_V3 | Linked to BASIC |
COMMAND_CLASS_SCENE_ACTIVATION_V1 | |
COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1 | |
COMMAND_CLASS_METER_V3 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_ALARM_V8 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V2 | |
COMMAND_CLASS_SECURITY_V1 |
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.