This describes the Z-Wave device 10002041-13X, manufactured by SimonTech S.L.U with the thing type UID of simontech_1000204113x_00_000
.
The device is in the category of Power Outlet, defining Small devices to be plugged into a power socket in a wall which stick there.
The 10002041-13X supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
Once plugged to 10002432-039 this front permits the direct control of a load plugged toggling it each time that the pushbutton is pressed. It is also possible to control the load using Z- Wave devices.
KeyPad long press (2s<t<30s) -> Central LED blinks until release of Pushbutton -> The Node Information Frame is sent via Z- Wave.
KeyPad long press (2s<t<30s) -> Central LED blinks until release of Pushbutton -> The Node Information Frame is sent via Z- Wave.
The following table summarises the channels available for the 10002041-13X -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Switch | switch_binary | switch_binary | Switch | Switch |
Electric meter (amps) | meter_current | meter_current | Energy | Number |
Electric meter (watts) | meter_watts | meter_watts | Energy | Number |
Electric meter (volts) | meter_voltage | meter_voltage | Energy | Number |
Switch the power on and off.
The switch_binary
channel is of type switch_binary
and supports the Switch
item and is in the Switch
category.
Indicates the instantaneous current consumption.
The meter_current
channel is of type meter_current
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous power consumption.
The meter_watts
channel is of type meter_watts
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous voltage.
The meter_voltage
channel is of type meter_voltage
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
The following table provides a summary of the 9 configuration parameters available in the 10002041-13X. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Association LED | Turns ON/OFF the Association LED |
2 | Custom consumption limit | Custom consumption limit |
3 | Beacon | Beacon LEDs |
10 | Delay ON | Delay |
11 | Activation TIME | Activation TIME |
12 | LED in Repose | Behavior of LED in Repose |
13 | Lock Input | |
15 | Reset | Reset default |
16 | Delay OFF | Delay OFF |
Turns ON/OFF the Association LED
The following option values may be configured -:
Value | Description |
---|---|
0 | Default |
255 | Center LED ON |
The manufacturer defined default value is 0
(Default).
This parameter has the configuration ID config_1_1_wo
and is of type INTEGER
.
This is a write only parameter.
Custom consumption limit 0x0001 - 0xFFFF -> Sets the power in Watts that is supported. (once the load is over, it is disconnected). Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_2_2
and is of type INTEGER
.
Beacon LEDs 0x01-0x63 (1-100%) -> Sets the intensity of the beacon LEDs. The following option values may be configured, in addition to values in the range 0 to 99 -:
Value | Description |
---|---|
0 | Disables the beacon function |
49 | Beacon LED at 50% |
99 | Beacon LED at 100% |
The manufacturer defined default value is 0
(Disables the beacon function).
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
Delay
- 0x00 -> (Default) Disables timing
- 0x01-0x7F -> Sets a timing with a range of (1-127sec)
- 0x80-0xFE -> Sets a timing with range of (1-127min) Values in the range 0 to 254 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_10_1
and is of type INTEGER
.
Activation TIME
- 0x00 -> (Default) Disables timing
- 0x01-0x7F -> Sets a timing with a range of (1-127sec)
- 0x80-0xFE -> Sets a timing with range of (1-127min) Values in the range 0 to 254 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_11_1
and is of type INTEGER
.
Behavior of LED in Repose
The following option values may be configured -:
Value | Description |
---|---|
0 | Off |
255 | On |
The manufacturer defined default value is 255
(ON).
This parameter has the configuration ID config_12_1
and is of type INTEGER
.
The following option values may be configured -:
Value | Description |
---|---|
0 | Default |
255 | Disables pushbutton |
The manufacturer defined default value is 0
(Default).
This parameter has the configuration ID config_13_1
and is of type INTEGER
.
Reset default
The following option values may be configured -:
Value | Description |
---|---|
17170 | All parameters except Long Pulse Lock. |
39015 | Restored to default |
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_15_2_wo
and is of type INTEGER
.
This is a write only parameter.
Delay OFF
- 0x00 -> (Default) Disables timing
- 0x01-0x7F -> Sets a timing with a range of (1-127sec)
- 0x80-0xFE -> Sets a timing with range of (1-127min) Values in the range 0 to 254 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_16_1
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The 10002041-13X supports 2 association groups.
The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. Group 1 (Lifeline) -> Name “lifeline” COMMAND_CLASS_BASIC_REPORT
It is sent to the associated nodes when the load changes state:
- ON -> 0xFF
- OFF -> 0x00
COMMAND_CLASS_METER_REPORT_V4
It is sent to the associated nodes when the power consumed varies more than 10%
“Electric meter”, “Consumed”, “Watts”, Size 4, Precision 1, Value (W)
COMMAND_CLASS_DEVICE_RESET_LOCALLY_ NOTIFICATION
The associated nodes are sent when the device is deleted from the Z-Wave network
Association group 1 supports 3 nodes.
Group 2 (Control) -> Name “ctrl" COMMAND_CLASS_BASIC_REPORT
It is sent to the associated nodes when the load changes state:
- ON -> 0xFF
- OFF -> 0x00
Association group 2 supports 20 nodes.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | |
COMMAND_CLASS_METER_V3 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V2 |