This describes the Z-Wave device 10002034-13X, manufactured by SimonTech S.L.U with the thing type UID of simontech_10000322039_00_000
.
The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.
The 10002034-13X supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
Simon Electronic Switch IO integrated by Electronic Switch that provides power Switch and Rocker that provides Z-Wave communication attributes.
- Put controller into inclusion mode.
- When the pushbutton is released after a press of (2sec<T<20sec) the device will send a NIF to include the device to the Z-Wave network. Main LED will blink with 0,3 sec period.
- Put controller into exclusion mode.
- When the pushbutton is released after a press of (2sec<T<20sec) the device will send a NIF to exclude the device from the Z-Wave network. Main LED will blink with 0,3 sec period.
The following table summarises the channels available for the 10002034-13X -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Switch | switch_binary | switch_binary | Switch | Switch |
Electric meter (watts) | meter_watts | meter_watts | Energy | Number |
Switch the power on and off.
The switch_binary
channel is of type switch_binary
and supports the Switch
item and is in the Switch
category.
Indicates the instantaneous power consumption.
The meter_watts
channel is of type meter_watts
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
The following table provides a summary of the 7 configuration parameters available in the 10002034-13X. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Association LED | Association LED |
10 | Delay ON | Delay from activation request until load activation |
11 | Activation Time | Time that load performs activated after complete an activation process. |
12 | Behavior of LED in Reponse | Configuration of Main LED as identification at 20%. |
13 | Lock Input | Locks the pushbutton and wired input actions. |
15 | Reset Default | Parameters, Groups, and Z-Wave status are restored to default. |
16 | Delay OFF | Delay from deactivation request until load deactivation. |
Association LED
The following option values may be configured -:
Value | Description |
---|---|
0 | Turns the main LED OFF |
255 | Turns the main LED ON |
The manufacturer defined default value is 0
(Turns the main LED OFF).
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
This is a read only parameter.
Delay from activation request until load activation 0-127 Delay in seconds, 128-254 Delay in minutes Values in the range 0 to 254 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_10_1
and is of type INTEGER
.
Time that load performs activated after complete an activation process. 0-127 Delay in seconds, 128-254 Delay in minutes Values in the range 0 to 254 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_11_1
and is of type INTEGER
.
Configuration of Main LED as identification at 20%.
The following option values may be configured -:
Value | Description |
---|---|
0 | LED OFF |
255 | LED ON at 20% of maximum level |
The manufacturer defined default value is 0
(LED OFF).
This parameter has the configuration ID config_12_1
and is of type INTEGER
.
Locks the pushbutton and wired input actions.
The following option values may be configured -:
Value | Description |
---|---|
0 | Unlock the direct control of load |
255 | Lock the direct control of load |
The manufacturer defined default value is 0
(Unlock the direct control of load).
This parameter has the configuration ID config_13_1
and is of type INTEGER
.
Parameters, Groups, and Z-Wave status are restored to default.
The following option values may be configured -:
Value | Description |
---|---|
0 | Normal operating mode |
39015 | Reset to Factory Defaults |
The manufacturer defined default value is 0
(Normal operating mode).
This parameter has the configuration ID config_15_2_wo
and is of type INTEGER
.
This is a write only parameter.
Delay from deactivation request until load deactivation. 0-127 Delay in seconds, 128-254 Delay in minutes Values in the range 0 to 254 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_16_1
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The 10002034-13X supports 1 association group.
The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation.
Association group 1 supports 3 nodes.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_METER_V3 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V2 |