layout title
documentation
10002034-13X - ZWave

{% include base.html %}

10002034-13X Switch IO: On/Off Power Switch

This describes the Z-Wave device 10002034-13X, manufactured by SimonTech S.L.U with the thing type UID of simontech_10000322039_00_000.

The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.

10002034-13X product image

The 10002034-13X supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

Simon Electronic Switch IO integrated by Electronic Switch that provides power Switch and Rocker that provides Z-Wave communication attributes.

Inclusion Information

  1. Put controller into inclusion mode.
  2. When the pushbutton is released after a press of (2sec<T<20sec) the device will send a NIF to include the device to the Z-Wave network. Main LED will blink with 0,3 sec period.

Exclusion Information

  1. Put controller into exclusion mode.
  2. When the pushbutton is released after a press of (2sec<T<20sec) the device will send a NIF to exclude the device from the Z-Wave network. Main LED will blink with 0,3 sec period.

Channels

The following table summarises the channels available for the 10002034-13X -:

Channel Name Channel ID Channel Type Category Item Type
Switch switch_binary switch_binary Switch Switch
Electric meter (watts) meter_watts meter_watts Energy Number

Switch

Switch the power on and off.

The switch_binary channel is of type switch_binary and supports the Switch item and is in the Switch category.

Electric meter (watts)

Indicates the instantaneous power consumption.

The meter_watts channel is of type meter_watts and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Device Configuration

The following table provides a summary of the 7 configuration parameters available in the 10002034-13X. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Association LED Association LED
10 Delay ON Delay from activation request until load activation
11 Activation Time Time that load performs activated after complete an activation process.
12 Behavior of LED in Reponse Configuration of Main LED as identification at 20%.
13 Lock Input Locks the pushbutton and wired input actions.
15 Reset Default Parameters, Groups, and Z-Wave status are restored to default.
16 Delay OFF Delay from deactivation request until load deactivation.

Parameter 1: Association LED

Association LED

The following option values may be configured -:

Value Description
0 Turns the main LED OFF
255 Turns the main LED ON

The manufacturer defined default value is 0 (Turns the main LED OFF).

This parameter has the configuration ID config_1_1 and is of type INTEGER. This is a read only parameter.

Parameter 10: Delay ON

Delay from activation request until load activation 0-127 Delay in seconds, 128-254 Delay in minutes Values in the range 0 to 254 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_10_1 and is of type INTEGER.

Parameter 11: Activation Time

Time that load performs activated after complete an activation process. 0-127 Delay in seconds, 128-254 Delay in minutes Values in the range 0 to 254 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_11_1 and is of type INTEGER.

Parameter 12: Behavior of LED in Reponse

Configuration of Main LED as identification at 20%.

The following option values may be configured -:

Value Description
0 LED OFF
255 LED ON at 20% of maximum level

The manufacturer defined default value is 0 (LED OFF).

This parameter has the configuration ID config_12_1 and is of type INTEGER.

Parameter 13: Lock Input

Locks the pushbutton and wired input actions.

The following option values may be configured -:

Value Description
0 Unlock the direct control of load
255 Lock the direct control of load

The manufacturer defined default value is 0 (Unlock the direct control of load).

This parameter has the configuration ID config_13_1 and is of type INTEGER.

Parameter 15: Reset Default

Parameters, Groups, and Z-Wave status are restored to default.

The following option values may be configured -:

Value Description
0 Normal operating mode
39015 Reset to Factory Defaults

The manufacturer defined default value is 0 (Normal operating mode).

This parameter has the configuration ID config_15_2_wo and is of type INTEGER. This is a write only parameter.

Parameter 16: Delay OFF

Delay from deactivation request until load deactivation. 0-127 Delay in seconds, 128-254 Delay in minutes Values in the range 0 to 254 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_16_1 and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The 10002034-13X supports 1 association group.

Group 1: Lifeline

The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation.

Association group 1 supports 3 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC
COMMAND_CLASS_METER_V3
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_VERSION_V2

Documentation Links


Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.