NAS-WR01ZE Wall Plug Switch

This describes the Z-Wave device NAS-WR01ZE, manufactured by Shenzhen Neo Electronics Co., Ltd with the thing type UID of shenzhen_coolcampwrplug_00_000.

The device is in the category of Power Outlet, defining Small devices to be plugged into a power socket in a wall which stick there.

NAS-WR01ZE product image

The NAS-WR01ZE supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

This Plug provides line voltage, current load, power consumption and energy consumption measuring. 

  • Voltage – The Supply Power Voltage For Plug.
  • Current – The Current for the Electric Device Connect to Plug Consumption.
  • Power – Power Consumed by an Electric Device in an instant, unit: Watt (W).
  • Energy – Energy Consumed by an Electric Device through a Time Period. Most commonly measured in Kilowatt-hours (kWh). One kilowatt-hour is Equal to One Kilowatt of Power Consumed over a Period of One Hour, 1kWh = 1000Wh.0Wh. 

Inclusion Information

  1. Make sure the sensor is powered.
  2. Set Z‐Wave controller or Z‐Wave gateway into inclusion mode (Refer to the controller or gateway operating manual)
  3. Press the button three times within 1.5 second, the device will enter inclusion mode. And the LED will flash on and off with green alternately five times within 2 seconds.

Exclusion Information

  1. Make sure the sensor is powered.
  2. Set Z‐Wave controller or Z‐Wave gateway into exclusion mode (Refer to the controller or gateway operating manual)
  3. Press the button three times within 1.5 second, the device will enter exclusion mode. And the LED will flash on and off with yellow alternately five times within 2 seconds.

Channels

The following table summarises the channels available for the NAS-WR01ZE -:

Channel Name Channel ID Channel Type Category Item Type
Switch switch_binary switch_binary Switch Switch
Electric meter (kWh) meter_kwh meter_kwh Energy Number
Electric meter (watts) meter_watts meter_watts Energy Number
Electric meter (amps) meter_current meter_current Energy Number
Electric meter (volts) meter_voltage meter_voltage Energy Number
Clear Accumulated Energy meter_reset meter_reset Energy Switch
Alarm (power) alarm_power alarm_power Energy Switch

Switch

Switch the power on and off.

The switch_binary channel is of type switch_binary and supports the Switch item and is in the Switch category.

Electric meter (kWh)

Indicates the energy consumption (kWh).

The meter_kwh channel is of type meter_kwh and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (watts)

Indicates the instantaneous power consumption.

The meter_watts channel is of type meter_watts and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (amps)

Indicates the instantaneous current consumption.

The meter_current channel is of type meter_current and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (volts)

Indicates the instantaneous voltage.

The meter_voltage channel is of type meter_voltage and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Clear Accumulated Energy

Reset the meter.

The meter_reset channel is of type meter_reset and supports the Switch item and is in the Energy category.

Alarm (power)

Indicates if a power alarm is triggered.

The alarm_power channel is of type alarm_power and supports the Switch item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Device Configuration

The following table provides a summary of the 11 configuration parameters available in the NAS-WR01ZE. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Relay On/Off State Saved Disable Relay On/Off State Saved Disable
2 Button Switch Function Disable Button Switch Function Disable
3 LED indication Disable LED indication Disable
4 Timer Enable Timer Enable
5 Timing Length Setting Timing Length Setting
6 Meter reporting function Meter reporting function
7 Interval of meter reporting setting Interval of meter reporting setting
8 Maximum output current setting Maximum output current setting
9 Current Differential Setting Current Differential Setting
10 Current Alarm Value Current Alarm Value
11 Clear Accumulated Energy Clear accumulated energy
Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Parameter 1: Relay On/Off State Saved Disable

Relay On/Off State Saved Disable

The following option values may be configured -:

Value Description
0 Do not save Relay State
1 Save Relay State

The manufacturer defined default value is 1 (Save Relay State).

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Parameter 2: Button Switch Function Disable

Button Switch Function Disable

The following option values may be configured -:

Value Description
0 Button disabled
1 Button enabled

The manufacturer defined default value is 1 (Button enabled).

This parameter has the configuration ID config_2_1 and is of type INTEGER.

Parameter 3: LED indication Disable

LED indication Disable

The following option values may be configured -:

Value Description
0 Disable LED
1 Enable LED

The manufacturer defined default value is 1 (Enable LED).

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Parameter 4: Timer Enable

Timer Enable

The following option values may be configured -:

Value Description
0 Timer Disable
1 Timer Enable

The manufacturer defined default value is 0 (Timer Disable).

This parameter has the configuration ID config_4_1 and is of type INTEGER.

Parameter 5: Timing Length Setting

Timing Length Setting

Values in the range 0 to 32767 may be set.

The manufacturer defined default value is 120.

This parameter has the configuration ID config_5_2 and is of type INTEGER.

Parameter 6: Meter reporting function

Meter reporting function

The following option values may be configured -:

Value Description
0 Disable Meter Report
1 Enable Meter Report

The manufacturer defined default value is 1 (Enable Meter Report).

This parameter has the configuration ID config_6_1 and is of type INTEGER.

Parameter 7: Interval of meter reporting setting

Interval of meter reporting setting

Values in the range 30 to 32767 may be set.

The manufacturer defined default value is 300.

This parameter has the configuration ID config_7_2 and is of type INTEGER.

Parameter 8: Maximum output current setting

Maximum output current setting The Value must be greather than the alarm value defined in Parameter 10 Values in the range 1 to 16 may be set.

The manufacturer defined default value is 16.

This parameter has the configuration ID config_8_1 and is of type INTEGER.

Parameter 9: Current Differential Setting

Current Differential Setting

Values in the range 1 to 1600 may be set.

The manufacturer defined default value is 50.

This parameter has the configuration ID config_9_2 and is of type INTEGER.

Parameter 10: Current Alarm Value

Current Alarm Value The Value must be less than the max. output value defined in Parameter 8 Values in the range 1 to 15 may be set.

The manufacturer defined default value is 13.

This parameter has the configuration ID config_10_1 and is of type INTEGER.

Parameter 11: Clear Accumulated Energy

Clear accumulated energy If this parameter is set to '0' or default, the accumulated energy saved in the plug will be cleared by '0'.
Other values will not change current accumulated energy value.
This parameter value cannot be saved in NVR mounted in the plug. The accumulated energy consumed will not be changed when the plug is added or removed from the Z-Wave network, but this value will be cleared after resetting the plug to factory default settings.

Note: Users can also send METER_RESET (Meter Command Class) command to clear accumulated energy. The following option values may be configured -:

Value Description
0 Save accumulated energy
1 Clear Accumulated Energy

The manufacturer defined default value is 0 (Save accumulated energy).

This parameter has the configuration ID config_11_1 and is of type INTEGER.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -:

Value Description
0 Exclude from All On and All Off groups
1 Include in All On group
2 Include in All Off group
255 Include in All On and All Off groups

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The NAS-WR01ZE supports 3 association groups.

Group 1: Lifeline

The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. Assigned to Plugs status - On/Off. Allows for receiving control command from trigger devices whenever the Plug is turned On or Off.

  • NOTIFICATION_REPORT_V4
  • METER_REPORT_V4
  • SWITCH_BINARY_REPORT
  • DEVICE_RESET_LOCALLY_NOTIFICATION

Association group 1 supports 1 node.

Group 2: Group 2

Sending control commands to associated devices. If current load is over the max current defined in parameter #3, the Plug will send a BASIC_SET (0xFF) to associated devices. When current load is normal, plug will send a BASIC_SET (0x00). BASIC_SET

Association group 2 supports 5 nodes.

Group 3: Group 3

Send Notification to associated devices. NOTIFICATION_REPORT_V4

Association group 3 supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC
COMMAND_CLASS_SWITCH_ALL_V1
COMMAND_CLASS_METER_V3
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_ALARM_V8
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_VERSION_V2
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3
COMMAND_CLASS_SECURITY_V1