This describes the Z-Wave device ZXT-600, manufactured by Remotec with the thing type UID of remotec_zxt600_01_003
.
This version of the device is limited to firmware versions above 1.3
The device is in the category of Remote Control, defining Any portable or hand-held device that controls the status of something, e.g. remote control, keyfob etc..
The ZXT-600 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
ZXT-600 AC Master is a Z-Wave plus certified IR Bridge for split air conditioner control by receiving Z-Wave command and translating to Infrared command and flawlessly work with any Z-Wave compliant gateway.
With its over 250 brands built-in code library and ever-green up to date cloud IR database supporting advanced code learning search, ZXT-600 can easily set up and smart control most of AC brands and models actively worldwide by Z-Wave gateway.
The battery powered device will allow you to mount it anywhere you want such as wall, ceiling or put it on table and never compromise on the form factor. By supporting OTA function, gateway can enable ZXT-600 to update firmware if newest available.
Please consult your Gateway supplier for more detail. Normally, User can ignore this step during the setup. ZXT-600 supports 1 association group Association Group #1 Association Group #1 (max. 1 node) is default to associate with the primary controller (Gateway/Hub/Controller) for AC Master Status change report, refer to below for report details:
- Current Room Temperature (report in precision of 0.5°C or 1°F) (It will be according to Configuration Parameter 39 setting to decide the trigger level)
- Current Battery Level (Only apply in Low Battery Warning happened)
- Device Reset Locally Notification (Only report when the AC Master has been triggered the RESET TO DEFAULT)
Step 1 Apply Power to ZXT-600
- 2x AA batteries or micro USB
- ZXT-600 will detect the first applied power source to decide what Z-Wave device role it will be in after included into the Z-Wave gateway: battery= sleeping device (FLiRS mode). USB power = always awake device (Always Listening mode), refer to Z-Wave Glossary for more information.
- Once the ZXT-600 is included into a Z-Wave network, the working mode (sleeping or awake) cannot be changed, unless it is excluded and re-apply the power.
- ZXT-600 can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers and/or other applications. All non-battery operated nodes within the network will act as repeaters regardless of Vendor to increase reliability of the network.
Step 2 Include ZXT-600 to a Z-Wave Gateway
Step Procedure / Description Status Indicator 1 Refer to your primary controller to enter into the Inclusion Mode or Exclusion Mode 2 When it is prompted to enter it, please triple click the “PROG” button within 1 second. Green Indicator flashes TWICE then stay off.
Red Indicator flashes TWICE then stay off to represent the Add / Remove process failed, please repeat the above step again. If the Add (Include) process fails, try Remove (Exclude) and /or resetting the AC Master to Factory Default and repeat the above step
The following table summarises the channels available for the ZXT-600 -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Sensor (temperature) | sensor_temperature | sensor_temperature | Temperature | Number:Temperature |
Thermostat mode | thermostat_mode | thermostat_mode | Temperature | Number |
Setpoint (heating) | thermostat_setpoint | thermostat_setpoint | Heating | Number:Temperature |
Setpoint (cooling) | thermostat_setpoint | thermostat_setpoint | Heating | Number:Temperature |
Thermostat fan mode | thermostat_fanmode | thermostat_fanmode |
Indicates the current temperature.
The sensor_temperature
channel is of type sensor_temperature
and supports the Number:Temperature
item and is in the Temperature
category.
Sets the thermostat.
The thermostat_mode
channel is of type thermostat_mode
and supports the Number
item and is in the Temperature
category.
The following state translation is provided for this channel to the Number
item type -:
Value | Label |
---|---|
0 | Off |
1 | Heat |
2 | Cool |
3 | Auto |
4 | Aux Heat |
5 | Resume |
6 | Fan Only |
7 | Furnace |
8 | Dry Air |
9 | Moist Air |
10 | Auto Changeover |
11 | Heat Economy |
12 | Cool Economy |
13 | Away |
Sets the thermostat setpoint.
The thermostat_setpoint
channel is of type thermostat_setpoint
and supports the Number:Temperature
item and is in the Heating
category.
Sets the thermostat setpoint.
The thermostat_setpoint
channel is of type thermostat_setpoint
and supports the Number:Temperature
item and is in the Heating
category.
Channel type information on this channel is not found.
The following table provides a summary of the 8 configuration parameters available in the ZXT-600. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
25 | Learn IR Code | Learn IR Code |
26 | Check IR Code Learning Status | Check IR Code Learning Status |
27 | Set IR Code Number from built-in code library | Set IR Code Number from built-in code library |
30 | Auto Report condi Trig by Room Temp change | Set Auto Report condition Trigger by Room Temperature change |
32 | Set built-in IR Emitter Control | Set built-in IR Emitter Control |
33 | Control AC SWING function | Control AC "SWING" function |
34 | Set Auto Report Cond by Time Interv | Set Auto Report Condition by Time Interval |
37 | Calibrate Temperature reading | Calibrate Temperature reading |
Learn IR Code This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 32 may be set.
The manufacturer defined default value is 32
.
This parameter has the configuration ID config_25_1
and is of type INTEGER
.
Check IR Code Learning Status
Values in the range 0 to 4 may be set.
The manufacturer defined default value is 4
.
This parameter has the configuration ID config_26_1
and is of type INTEGER
.
This is a read only parameter.
Set IR Code Number from built-in code library This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_27_2
and is of type INTEGER
.
Set Auto Report condition Trigger by Room Temperature change
Values in the range 0 to 8 may be set.
The manufacturer defined default value is 8
.
This parameter has the configuration ID config_30_1
and is of type INTEGER
.
Set built-in IR Emitter Control 0 - disable
255 enable (default)This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 255 may be set.
The manufacturer defined default value is 255
.
This parameter has the configuration ID config_32_1
and is of type INTEGER
.
Control AC "SWING" function 0 - swing off
1 - swing on (default) Values in the range 0 to 1 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_33_1
and is of type INTEGER
.
Set Auto Report Condition by Time Interval
Values in the range 1 to 8 may be set.
The manufacturer defined default value is 8
.
This parameter has the configuration ID config_34_1
and is of type INTEGER
.
Calibrate Temperature reading 0 to 5 - positive value
251 to 255 - negatice value Values in the range 0 to 255 may be set.
The manufacturer defined default value is 5
.
This parameter has the configuration ID config_37_1
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The ZXT-600 supports 1 association group.
The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. Z-Wave Plus Lifeline
Association group 1 supports 1 node.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_APPLICATION_STATUS_V1 | |
COMMAND_CLASS_SENSOR_MULTILEVEL_V7 | |
COMMAND_CLASS_THERMOSTAT_MODE_V1 | |
COMMAND_CLASS_THERMOSTAT_SETPOINT_V1 | |
COMMAND_CLASS_THERMOSTAT_FAN_MODE_V1 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V2 | |
COMMAND_CLASS_SECURITY_V1 |