This describes the Z-Wave device ZXT-120, manufactured by Remotec with the thing type UID of remotec_zxt120_00_000
.
The device is in the category of HVAC, defining Air condition devices, Fans.
The ZXT-120 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.
The ZXT-120 is a Z-Wave to air-conditioner (AC) IR Extender and it works with any Z-Wave compliant gateway which supports the same command classes (check with your gateway support for compatibility) or portable controller by translating Z-Wave’s Thermostat commands to AC IR control code. User can set the IR code from the built-in code library of ZXT-120 through the configuration commands, or use the learning function of ZXT-120 through the UI on gateway. ZXT-120 also built in a temperature sensor that allow to report your room temperature to home gateway.
Click once on the PROG button
Click once on the PROG button
The following table summarises the channels available for the ZXT-120 -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Sensor (temperature) | sensor_temperature | sensor_temperature | Temperature | Number:Temperature |
Thermostat mode | thermostat_mode | thermostat_mode | Temperature | Number |
Setpoint (cooling) | thermostat_setpoint | thermostat_setpoint | Heating | Number:Temperature |
Setpoint (heating) | thermostat_setpoint | thermostat_setpoint | Heating | Number:Temperature |
Thermostat fan mode | thermostat_fanmode | thermostat_fanmode | ||
Battery Level | battery-level | system.battery_level | Battery | Number |
Indicates the current temperature.
The sensor_temperature
channel is of type sensor_temperature
and supports the Number:Temperature
item and is in the Temperature
category.
Sets the thermostat.
The thermostat_mode
channel is of type thermostat_mode
and supports the Number
item and is in the Temperature
category.
The following state translation is provided for this channel to the Number
item type -:
Value | Label |
---|---|
0 | Off |
1 | Heat |
2 | Cool |
3 | Auto |
4 | Aux Heat |
5 | Resume |
6 | Fan Only |
7 | Furnace |
8 | Dry Air |
9 | Moist Air |
10 | Auto Changeover |
11 | Heat Economy |
12 | Cool Economy |
13 | Away |
Sets the thermostat setpoint.
The thermostat_setpoint
channel is of type thermostat_setpoint
and supports the Number:Temperature
item and is in the Heating
category.
Sets the thermostat setpoint.
The thermostat_setpoint
channel is of type thermostat_setpoint
and supports the Number:Temperature
item and is in the Heating
category.
Channel type information on this channel is not found.
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
The system.battery-level
channel is of type system.battery-level
and supports the Number
item and is in the Battery
category.
This channel provides the battery level as a percentage and also reflects the low battery warning state. If the battery state is in low battery warning state, this will read 0%.
The following table provides a summary of the 8 configuration parameters available in the ZXT-120. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
25 | Location | Location |
26 | Learning status register (Read Only) | |
27 | IR code number for built-in code library | |
28 | External IR Emitter power level | |
32 | Surround IR control | |
33 | AC function Swing control | |
35 | Learn location status. Bitmask. (Read Only) | |
37 | Sensor temperature compensation | |
Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands |
Location Indicate a location for IR code learning and start learning Values in the range 0 to 22 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_25_1
and is of type INTEGER
.
Values in the range 0 to 4 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_26_1
and is of type INTEGER
.
This is a read only parameter.
Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_27_2
and is of type INTEGER
.
The following option values may be configured -:
Value | Description |
---|---|
0 | Normal power mode |
255 | High power mode |
The manufacturer defined default value is 255
(High power mode).
This parameter has the configuration ID config_28_1
and is of type INTEGER
.
The following option values may be configured -:
Value | Description |
---|---|
-1 | Enable Surround IR Emitters |
0 | Disable Surround IR Emitters |
The manufacturer defined default value is -1
(Enable Surround IR Emitters).
This parameter has the configuration ID config_32_1
and is of type INTEGER
.
The following option values may be configured -:
Value | Description |
---|---|
0 | Swing Off |
1 | Swing Auto |
The manufacturer defined default value is 1
(Swing Auto).
This parameter has the configuration ID config_33_1
and is of type INTEGER
.
Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_35_4
and is of type INTEGER
.
This is a read only parameter.
Values in the range -5 to 5 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_37_1
and is of type INTEGER
.
Set the mode for the switch when receiving SWITCH ALL commands.
The following option values may be configured -:
Value | Description |
---|---|
0 | Exclude from All On and All Off groups |
1 | Include in All On group |
2 | Include in All Off group |
255 | Include in All On and All Off groups |
This parameter has the configuration ID switchall_mode
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The device does not support associations.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_ALL_V1 | |
COMMAND_CLASS_SENSOR_MULTILEVEL_V1 | |
COMMAND_CLASS_THERMOSTAT_MODE_V2 | |
COMMAND_CLASS_THERMOSTAT_SETPOINT_V2 | |
COMMAND_CLASS_THERMOSTAT_FAN_MODE_V2 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_BATTERY_V1 | |
COMMAND_CLASS_VERSION_V1 |