This describes the Z-Wave device ZXT-120, manufactured by Remotec with the thing type UID of remotec_zxt120_00_000.

The device is in the category of HVAC, defining Air condition devices, Fans.

ZXT-120 product image

The ZXT-120 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.

Overview

The ZXT-120 is a Z-Wave to air-conditioner (AC) IR Extender and it works with any Z-Wave compliant gateway which supports the same command classes (check with your gateway support for compatibility) or portable controller by translating Z-Wave’s Thermostat commands to AC IR control code. User can set the IR code from the built-in code library of ZXT-120 through the configuration commands, or use the learning function of ZXT-120 through the UI on gateway. ZXT-120 also built in a temperature sensor that allow to report your room temperature to home gateway. 

Inclusion Information

Click once on the PROG button

Exclusion Information

Click once on the PROG button

Channels

The following table summarises the channels available for the ZXT-120 -:

Channel Name Channel ID Channel Type Category Item Type
Sensor (temperature) sensor_temperature sensor_temperature Temperature Number:Temperature
Thermostat mode thermostat_mode thermostat_mode Temperature Number
Setpoint (cooling) thermostat_setpoint thermostat_setpoint Heating Number:Temperature
Setpoint (heating) thermostat_setpoint thermostat_setpoint Heating Number:Temperature
Thermostat fan mode thermostat_fanmode thermostat_fanmode
Battery Level battery-level system.battery_level Battery Number

Sensor (temperature)

Indicates the current temperature.

The sensor_temperature channel is of type sensor_temperature and supports the Number:Temperature item and is in the Temperature category.

Thermostat mode

Sets the thermostat.

The thermostat_mode channel is of type thermostat_mode and supports the Number item and is in the Temperature category. The following state translation is provided for this channel to the Number item type -:

Value Label
0 Off
1 Heat
2 Cool
3 Auto
4 Aux Heat
5 Resume
6 Fan Only
7 Furnace
8 Dry Air
9 Moist Air
10 Auto Changeover
11 Heat Economy
12 Cool Economy
13 Away

Setpoint (cooling)

Sets the thermostat setpoint.

The thermostat_setpoint channel is of type thermostat_setpoint and supports the Number:Temperature item and is in the Heating category.

Setpoint (heating)

Sets the thermostat setpoint.

The thermostat_setpoint channel is of type thermostat_setpoint and supports the Number:Temperature item and is in the Heating category.

Thermostat fan mode

Channel type information on this channel is not found.

Battery Level

Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.

The system.battery-level channel is of type system.battery-level and supports the Number item and is in the Battery category. This channel provides the battery level as a percentage and also reflects the low battery warning state. If the battery state is in low battery warning state, this will read 0%.

Device Configuration

The following table provides a summary of the 8 configuration parameters available in the ZXT-120. Detailed information on each parameter can be found in the sections below.

Param Name Description
25 Location Location
26 Learning status register (Read Only)
27 IR code number for built-in code library
28 External IR Emitter power level
32 Surround IR control
33 AC function Swing control
35 Learn location status. Bitmask. (Read Only)
37 Sensor temperature compensation
Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Parameter 25: Location

Location Indicate a location for IR code learning and start learning Values in the range 0 to 22 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_25_1 and is of type INTEGER.

Parameter 26: Learning status register (Read Only)

Values in the range 0 to 4 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_26_1 and is of type INTEGER. This is a read only parameter.

Parameter 27: IR code number for built-in code library

Values in the range 0 to 65535 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_27_2 and is of type INTEGER.

Parameter 28: External IR Emitter power level

The following option values may be configured -:

Value Description
0 Normal power mode
255 High power mode

The manufacturer defined default value is 255 (High power mode).

This parameter has the configuration ID config_28_1 and is of type INTEGER.

Parameter 32: Surround IR control

The following option values may be configured -:

Value Description
-1 Enable Surround IR Emitters
0 Disable Surround IR Emitters

The manufacturer defined default value is -1 (Enable Surround IR Emitters).

This parameter has the configuration ID config_32_1 and is of type INTEGER.

Parameter 33: AC function Swing control

The following option values may be configured -:

Value Description
0 Swing Off
1 Swing Auto

The manufacturer defined default value is 1 (Swing Auto).

This parameter has the configuration ID config_33_1 and is of type INTEGER.

Parameter 35: Learn location status. Bitmask. (Read Only)

Values in the range 0 to 65535 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_35_4 and is of type INTEGER. This is a read only parameter.

Parameter 37: Sensor temperature compensation

Values in the range -5 to 5 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_37_1 and is of type INTEGER.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -:

Value Description
0 Exclude from All On and All Off groups
1 Include in All On group
2 Include in All Off group
255 Include in All On and All Off groups

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The device does not support associations.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_ALL_V1
COMMAND_CLASS_SENSOR_MULTILEVEL_V1
COMMAND_CLASS_THERMOSTAT_MODE_V2
COMMAND_CLASS_THERMOSTAT_SETPOINT_V2
COMMAND_CLASS_THERMOSTAT_FAN_MODE_V2
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_BATTERY_V1
COMMAND_CLASS_VERSION_V1

Documentation Links


Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.