ZTS-110 ZTS-110 Z Wave Thermostat

This describes the Z-Wave device ZTS-110, manufactured by Remotec with the thing type UID of remotec_zts110_00_000.

The device is in the category of HVAC, defining Air condition devices, Fans.

ZTS-110 product image

The ZTS-110 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.

Overview

ZTS-110 Z-Thermostat is a Z-Wave enabled programmable thermostat that allows you to control your room temperature with programmable time schedule such as WAKE, AWAY, HOME and SLEEP event which can maximize energy conservation and comfort while minimizing the effort required to maintaining the appropriate temperature in your home whether you are at home or away.

Also, you can use the ZTS-110 to control / check your room temperature by smart phone or PC while you are at home or outside through Z-Wave gateway.

Read following scenarios carefully before you start as it matters to the battery life under Z-Wave operation:

ZTS-110 can be powered by 4 x AA batteries, and/or 24Vac C wire.

  1. If it is powered by batteries or powered by batteries first then applied with 24Vac before Z-Wave inclusion, ZTS-110 will self-configure to FLiRS mode which will save battery life by sleeping.
  2. If it is powered by 24Vac or powered by 24Vac first then applied with batteries before Z-Wave inclusion, ZTS-110 will self-configure to Always Listening Mode which will not sleep.
  3. After inclusion process, ZTS-110 will not detect power source and not allow changing operation mode. You must perform exclusion process first if need to change Z-Wave operation mode.
  4. After Z-Wave inclusion process, if you reset ZTS-110 to default while both 24Vac and batteries are applied, ZTS-110 will take 24Vac as primary power source and self-configure to Always Listening Mode, because reset to default process will automatically exclude ZTS-110 from the Z-Wave network. You should disconnect the power source and re-apply the power so ZTS-110 can detect the power source type and self-configure to corresponding mode.

Inclusion Information

  1. Press and hold "Home" key for 2 seconds to set ZTS-110 to Add (Inclusion) / Delete (Exclusion) Mode.
  2. Press "Prog" key once, it will search the network. 

Exclusion Information

  1. Press and hold "Home" key for 2 seconds to set ZTS-110 to Add (Inclusion) / Delete (Exclusion) Mode.
  2. Press "Prog" key once, it will search the network.

Channels

The following table summarises the channels available for the ZTS-110 -:

Channel Name Channel ID Channel Type Category Item Type
Sensor (temperature) sensor_temperature sensor_temperature Temperature Number:Temperature
Thermostat mode thermostat_mode thermostat_mode Temperature Number
Operating State thermostat_state thermostat_state Temperature Number
Setpoint (cooling) thermostat_setpoint thermostat_setpoint Heating Number:Temperature
Setpoint (heating) thermostat_setpoint thermostat_setpoint Heating Number:Temperature
Thermostat fan mode thermostat_fanmode thermostat_fanmode
Thermostat fan state thermostat_fanstate thermostat_fanstate
Battery Level battery-level system.battery_level Battery Number
Clock Time Offset time_offset time_offset Time Number

Sensor (temperature)

Indicates the current temperature.

The sensor_temperature channel is of type sensor_temperature and supports the Number:Temperature item and is in the Temperature category.

Thermostat mode

Sets the thermostat.

The thermostat_mode channel is of type thermostat_mode and supports the Number item and is in the Temperature category. The following state translation is provided for this channel to the Number item type -:

Value Label
0 Off
1 Heat
2 Cool
3 Auto
4 Aux Heat
5 Resume
6 Fan Only
7 Furnace
8 Dry Air
9 Moist Air
10 Auto Changeover
11 Heat Economy
12 Cool Economy
13 Away

Operating State

Sets the thermostat operating state.

The thermostat_state channel is of type thermostat_state and supports the Number item and is in the Temperature category. The following state translation is provided for this channel to the Number item type -:

Value Label
0 Idle
1 Heating
2 Cooling
3 Fan Only
4 Pending Heat
5 Pending Cool
6 Vent / Economiser

Setpoint (cooling)

Sets the thermostat setpoint.

The thermostat_setpoint channel is of type thermostat_setpoint and supports the Number:Temperature item and is in the Heating category.

Setpoint (heating)

Sets the thermostat setpoint.

The thermostat_setpoint channel is of type thermostat_setpoint and supports the Number:Temperature item and is in the Heating category.

Thermostat fan mode

Channel type information on this channel is not found.

Thermostat fan state

Channel type information on this channel is not found.

Battery Level

Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.

The system.battery-level channel is of type system.battery-level and supports the Number item and is in the Battery category. This channel provides the battery level as a percentage and also reflects the low battery warning state. If the battery state is in low battery warning state, this will read 0%.

Clock Time Offset

Provides the current time difference for the devices time.

The time_offset channel is of type time_offset and supports the Number item and is in the Time category.

Device Configuration

The following table provides a summary of the 13 configuration parameters available in the ZTS-110. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Swing Set Swing value from 1F/.5C to 4F/2.0C Available settings: 1 - 4
2 Differntial Set Differential value from 1F/.5C to 4F/2.0C Available settings: 1 - 4
3 Set Filter Counter Set filter replacement timer from 500 to 4000 hours.
4 Report Filter Counter READ ONLY: Data in hours
5 Scale of Temperature Set Temperature Scale to Farhenheit or Centigrade. DEFAULT =1 Farhenheit
6 Upper Limit of Setpoint A Upper Limit of Setpoint A
7 Lower Limit of Setpoint B Lower Limit of Setpoint B
8 Easy Mode Set Easy Mode 0:DISABLE 1:ENABLED DEFAULT:ENABLED
9 Time Format Configures for 12 or 24 Hour format. Default is 12 Hours.
10 Repeat Basic Set Counter Repeat Basic Set Counter
11 AUTO report by room temperature AUTO report by room temperature
12 Sensor temperature calibration. Sensor temperature calibration.
13 AUTO report by time interval. AUTO report by time interval.

Parameter 1: Swing

Set Swing value from 1F/.5C to 4F/2.0C Available settings: 1 - 4

Values in the range 1 to 4 may be set.

The manufacturer defined default value is 2.

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Parameter 2: Differntial

Set Differential value from 1F/.5C to 4F/2.0C Available settings: 1 - 4

Values in the range 1 to 4 may be set.

The manufacturer defined default value is 2.

This parameter has the configuration ID config_2_1 and is of type INTEGER.

Parameter 3: Set Filter Counter

Set filter replacement timer from 500 to 4000 hours.

Values in the range 500 to 4000 may be set.

The manufacturer defined default value is 500.

This parameter has the configuration ID config_3_2 and is of type INTEGER.

Parameter 4: Report Filter Counter

READ ONLY: Data in hours

Values in the range 0 to 9999 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_4_2 and is of type INTEGER.

Parameter 5: Scale of Temperature

Set Temperature Scale to Farhenheit or Centigrade. DEFAULT =1 Farhenheit

The following option values may be configured -:

Value Description
0 Centigrade
1 Farhenheit

The manufacturer defined default value is 1 (Farhenheit).

This parameter has the configuration ID config_5_1 and is of type INTEGER.

Parameter 6: Upper Limit of Setpoint A

Upper Limit of Setpoint A Determines Upper Limit of set point A. Unit in celsius A=(B+2)min (37.0 C)max, Unit in Fahrenheit A=(B+4)min (99.0 F)max   Values in the range 37 to 99 may be set.

The manufacturer defined default value is 99.

This parameter has the configuration ID config_6_2 and is of type INTEGER.

Parameter 7: Lower Limit of Setpoint B

Lower Limit of Setpoint B Determines Lower Limit of set point B. Unit in celsius (5.0 C to 35.0 C) Unit in Fahrenheit (41.0 F to 95.0  F)   Values in the range 5 to 95 may be set.

The manufacturer defined default value is 41.

This parameter has the configuration ID config_7_2 and is of type INTEGER.

Parameter 8: Easy Mode

Set Easy Mode 0:DISABLE 1:ENABLED DEFAULT:ENABLED

The following option values may be configured -:

Value Description
0 Easy Mode Disabled
1 Easy Mode Enabled

The manufacturer defined default value is 1 (Easy Mode Enabled).

This parameter has the configuration ID config_8_1 and is of type INTEGER.

Parameter 9: Time Format

Configures for 12 or 24 Hour format. Default is 12 Hours.

The following option values may be configured -:

Value Description
0 24 Hour Format
1 12 Hour Format

The manufacturer defined default value is 1 (12 Hour Format).

This parameter has the configuration ID config_9_1 and is of type INTEGER.

Parameter 10: Repeat Basic Set Counter

Repeat Basic Set Counter Thermostat sends 'Basic Set' command to its association node repeatedly ever X minutes.

  • 0 = Disabled or
  • Set to Enabled Values available 3 to 255.   Values in the range 0 to 255 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_10_1 and is of type INTEGER.

Parameter 11: AUTO report by room temperature

AUTO report by room temperature Trigger AUTO report if room temperature is different from last report.

  • 0 = Disabled or
  • set value from 1 to 8 where each number corresponds to 1 Degree F or .5 Degrees Celsius.   Values in the range 0 to 8 may be set.

The manufacturer defined default value is 4.

This parameter has the configuration ID config_11_1 and is of type INTEGER.

Parameter 12: Sensor temperature calibration.

Sensor temperature calibration.

  • 0 = Disabled or
  • set value from 1 to 10 in 1 degree F increments or -1 to -10 in 1 degree F increments .  Values in the range -10 to 10 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_12_1 and is of type INTEGER.

Parameter 13: AUTO report by time interval.

AUTO report by time interval.

  • 0 = Disabled or
  • set value from 1 to 16 where 1 = .5 hours and each consecutive number increases time by .5 hours.  Values in the range 0 to 16 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_13_1 and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The ZTS-110 supports 3 association groups.

Group 1: Heat Pump

Association group 1 supports 4 nodes.

Group 2: Compressor

Association group 2 supports 4 nodes.

Group 3: Controller Update

Association group 3 supports 1 node.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SENSOR_MULTILEVEL_V1
COMMAND_CLASS_THERMOSTAT_MODE_V1
COMMAND_CLASS_THERMOSTAT_OPERATING_STATE_V1
COMMAND_CLASS_THERMOSTAT_SETPOINT_V1
COMMAND_CLASS_THERMOSTAT_FAN_MODE_V1
COMMAND_CLASS_THERMOSTAT_FAN_STATE_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_BATTERY_V1
COMMAND_CLASS_CLOCK_V1
COMMAND_CLASS_ASSOCIATION_V1
COMMAND_CLASS_VERSION_V1