This describes the Z-Wave device ZTS-110, manufactured by Remotec with the thing type UID of remotec_zts110_00_000
.
The device is in the category of HVAC, defining Air condition devices, Fans.
The ZTS-110 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.
ZTS-110 Z-Thermostat is a Z-Wave enabled programmable thermostat that allows you to control your room temperature with programmable time schedule such as WAKE, AWAY, HOME and SLEEP event which can maximize energy conservation and comfort while minimizing the effort required to maintaining the appropriate temperature in your home whether you are at home or away.
Also, you can use the ZTS-110 to control / check your room temperature by smart phone or PC while you are at home or outside through Z-Wave gateway.
Read following scenarios carefully before you start as it matters to the battery life under Z-Wave operation:
ZTS-110 can be powered by 4 x AA batteries, and/or 24Vac C wire.
- If it is powered by batteries or powered by batteries first then applied with 24Vac before Z-Wave inclusion, ZTS-110 will self-configure to FLiRS mode which will save battery life by sleeping.
- If it is powered by 24Vac or powered by 24Vac first then applied with batteries before Z-Wave inclusion, ZTS-110 will self-configure to Always Listening Mode which will not sleep.
- After inclusion process, ZTS-110 will not detect power source and not allow changing operation mode. You must perform exclusion process first if need to change Z-Wave operation mode.
- After Z-Wave inclusion process, if you reset ZTS-110 to default while both 24Vac and batteries are applied, ZTS-110 will take 24Vac as primary power source and self-configure to Always Listening Mode, because reset to default process will automatically exclude ZTS-110 from the Z-Wave network. You should disconnect the power source and re-apply the power so ZTS-110 can detect the power source type and self-configure to corresponding mode.
- Press and hold "Home" key for 2 seconds to set ZTS-110 to Add (Inclusion) / Delete (Exclusion) Mode.
- Press "Prog" key once, it will search the network.
- Press and hold "Home" key for 2 seconds to set ZTS-110 to Add (Inclusion) / Delete (Exclusion) Mode.
- Press "Prog" key once, it will search the network.
The following table summarises the channels available for the ZTS-110 -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Sensor (temperature) | sensor_temperature | sensor_temperature | Temperature | Number:Temperature |
Thermostat mode | thermostat_mode | thermostat_mode | Temperature | Number |
Operating State | thermostat_state | thermostat_state | Temperature | Number |
Setpoint (cooling) | thermostat_setpoint | thermostat_setpoint | Heating | Number:Temperature |
Setpoint (heating) | thermostat_setpoint | thermostat_setpoint | Heating | Number:Temperature |
Thermostat fan mode | thermostat_fanmode | thermostat_fanmode | ||
Thermostat fan state | thermostat_fanstate | thermostat_fanstate | ||
Battery Level | battery-level | system.battery_level | Battery | Number |
Clock Time Offset | time_offset | time_offset | Time | Number |
Indicates the current temperature.
The sensor_temperature
channel is of type sensor_temperature
and supports the Number:Temperature
item and is in the Temperature
category.
Sets the thermostat.
The thermostat_mode
channel is of type thermostat_mode
and supports the Number
item and is in the Temperature
category.
The following state translation is provided for this channel to the Number
item type -:
Value | Label |
---|---|
0 | Off |
1 | Heat |
2 | Cool |
3 | Auto |
4 | Aux Heat |
5 | Resume |
6 | Fan Only |
7 | Furnace |
8 | Dry Air |
9 | Moist Air |
10 | Auto Changeover |
11 | Heat Economy |
12 | Cool Economy |
13 | Away |
Sets the thermostat operating state.
The thermostat_state
channel is of type thermostat_state
and supports the Number
item and is in the Temperature
category.
The following state translation is provided for this channel to the Number
item type -:
Value | Label |
---|---|
0 | Idle |
1 | Heating |
2 | Cooling |
3 | Fan Only |
4 | Pending Heat |
5 | Pending Cool |
6 | Vent / Economiser |
Sets the thermostat setpoint.
The thermostat_setpoint
channel is of type thermostat_setpoint
and supports the Number:Temperature
item and is in the Heating
category.
Sets the thermostat setpoint.
The thermostat_setpoint
channel is of type thermostat_setpoint
and supports the Number:Temperature
item and is in the Heating
category.
Channel type information on this channel is not found.
Channel type information on this channel is not found.
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
The system.battery-level
channel is of type system.battery-level
and supports the Number
item and is in the Battery
category.
This channel provides the battery level as a percentage and also reflects the low battery warning state. If the battery state is in low battery warning state, this will read 0%.
Provides the current time difference for the devices time.
The time_offset
channel is of type time_offset
and supports the Number
item and is in the Time
category.
The following table provides a summary of the 13 configuration parameters available in the ZTS-110. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Swing | Set Swing value from 1F/.5C to 4F/2.0C Available settings: 1 - 4 |
2 | Differntial | Set Differential value from 1F/.5C to 4F/2.0C Available settings: 1 - 4 |
3 | Set Filter Counter | Set filter replacement timer from 500 to 4000 hours. |
4 | Report Filter Counter | READ ONLY: Data in hours |
5 | Scale of Temperature | Set Temperature Scale to Farhenheit or Centigrade. DEFAULT =1 Farhenheit |
6 | Upper Limit of Setpoint A | Upper Limit of Setpoint A |
7 | Lower Limit of Setpoint B | Lower Limit of Setpoint B |
8 | Easy Mode | Set Easy Mode 0:DISABLE 1:ENABLED DEFAULT:ENABLED |
9 | Time Format | Configures for 12 or 24 Hour format. Default is 12 Hours. |
10 | Repeat Basic Set Counter | Repeat Basic Set Counter |
11 | AUTO report by room temperature | AUTO report by room temperature |
12 | Sensor temperature calibration. | Sensor temperature calibration. |
13 | AUTO report by time interval. | AUTO report by time interval. |
Set Swing value from 1F/.5C to 4F/2.0C Available settings: 1 - 4
Values in the range 1 to 4 may be set.
The manufacturer defined default value is 2
.
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
Set Differential value from 1F/.5C to 4F/2.0C Available settings: 1 - 4
Values in the range 1 to 4 may be set.
The manufacturer defined default value is 2
.
This parameter has the configuration ID config_2_1
and is of type INTEGER
.
Set filter replacement timer from 500 to 4000 hours.
Values in the range 500 to 4000 may be set.
The manufacturer defined default value is 500
.
This parameter has the configuration ID config_3_2
and is of type INTEGER
.
READ ONLY: Data in hours
Values in the range 0 to 9999 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_4_2
and is of type INTEGER
.
Set Temperature Scale to Farhenheit or Centigrade. DEFAULT =1 Farhenheit
The following option values may be configured -:
Value | Description |
---|---|
0 | Centigrade |
1 | Farhenheit |
The manufacturer defined default value is 1
(Farhenheit).
This parameter has the configuration ID config_5_1
and is of type INTEGER
.
Upper Limit of Setpoint A Determines Upper Limit of set point A. Unit in celsius A=(B+2)min (37.0 C)max, Unit in Fahrenheit A=(B+4)min (99.0 F)max Values in the range 37 to 99 may be set.
The manufacturer defined default value is 99
.
This parameter has the configuration ID config_6_2
and is of type INTEGER
.
Lower Limit of Setpoint B Determines Lower Limit of set point B. Unit in celsius (5.0 C to 35.0 C) Unit in Fahrenheit (41.0 F to 95.0 F) Values in the range 5 to 95 may be set.
The manufacturer defined default value is 41
.
This parameter has the configuration ID config_7_2
and is of type INTEGER
.
Set Easy Mode 0:DISABLE 1:ENABLED DEFAULT:ENABLED
The following option values may be configured -:
Value | Description |
---|---|
0 | Easy Mode Disabled |
1 | Easy Mode Enabled |
The manufacturer defined default value is 1
(Easy Mode Enabled).
This parameter has the configuration ID config_8_1
and is of type INTEGER
.
Configures for 12 or 24 Hour format. Default is 12 Hours.
The following option values may be configured -:
Value | Description |
---|---|
0 | 24 Hour Format |
1 | 12 Hour Format |
The manufacturer defined default value is 1
(12 Hour Format).
This parameter has the configuration ID config_9_1
and is of type INTEGER
.
Repeat Basic Set Counter Thermostat sends 'Basic Set' command to its association node repeatedly ever X minutes.
- 0 = Disabled or
- Set to Enabled Values available 3 to 255. Values in the range 0 to 255 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_10_1
and is of type INTEGER
.
AUTO report by room temperature Trigger AUTO report if room temperature is different from last report.
- 0 = Disabled or
- set value from 1 to 8 where each number corresponds to 1 Degree F or .5 Degrees Celsius. Values in the range 0 to 8 may be set.
The manufacturer defined default value is 4
.
This parameter has the configuration ID config_11_1
and is of type INTEGER
.
Sensor temperature calibration.
- 0 = Disabled or
- set value from 1 to 10 in 1 degree F increments or -1 to -10 in 1 degree F increments . Values in the range -10 to 10 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_12_1
and is of type INTEGER
.
AUTO report by time interval.
- 0 = Disabled or
- set value from 1 to 16 where 1 = .5 hours and each consecutive number increases time by .5 hours. Values in the range 0 to 16 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_13_1
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The ZTS-110 supports 3 association groups.
Association group 1 supports 4 nodes.
Association group 2 supports 4 nodes.
Association group 3 supports 1 node.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SENSOR_MULTILEVEL_V1 | |
COMMAND_CLASS_THERMOSTAT_MODE_V1 | |
COMMAND_CLASS_THERMOSTAT_OPERATING_STATE_V1 | |
COMMAND_CLASS_THERMOSTAT_SETPOINT_V1 | |
COMMAND_CLASS_THERMOSTAT_FAN_MODE_V1 | |
COMMAND_CLASS_THERMOSTAT_FAN_STATE_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_BATTERY_V1 | |
COMMAND_CLASS_CLOCK_V1 | |
COMMAND_CLASS_ASSOCIATION_V1 | |
COMMAND_CLASS_VERSION_V1 |
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.