ZME_05431 Switch

This describes the Z-Wave device ZME_05431, manufactured by Reitz-Group.de with the thing type UID of reitz_zme05431_00_000.

The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.

ZME_05431 product image

The ZME_05431 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

Inclusion/Exclusion

On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.

Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.

Inclusion

Blinking red/green LED indicates that the device is in factory reset state. Once the controller is turned into inclusion mode triple click of the buttons on the device will include the device. A green blinking of the LED will indicate successful inclusion that will be turned off shortly afterwards. The device is excluded by triple click to one of the buttons when the controller is in exclusion mode.

Exclusion

Blinking red/green LED indicates that the device is in factory reset state. Once the controller is turned into inclusion mode triple click of the buttons on the device will include the device. A green blinking of the LED will indicate successful inclusion that will be turned off shortly afterwards. The device is excluded by triple click to one of the buttons when the controller is in exclusion mode.

Product Usage

The actuator is operated by the local switching paddles or wirelessly using Z-Wave commands (communication patterns 1, 4, 5 and 7). If the insert is mounted correctly pushing the upper part of the paddle will turn on the load; pushing the lower part of the paddle will turn off the electric load.

The device is also able to report status changes to a controller (communication pattern 2) and to remotely operate other devices (communication pattern 5) by sending wireless Z-Wave commands. In case the remote device is a switch as well the remote operation is similar to the local operation by pushing upper to lower part of the switching paddle. However the device can also be configured with configuration parameter 13 and 14 to operate remote dimmers. To dim a remote device the paddle needs to be pushed and hold (upper part to dim up, lower part to dim down). Its furthermore possible to assign remote operation functions to the double click of the paddles.

Configuration parameter 2 enables a special function of the device. Its possible to define a timeout to automatically turn off the device after it was turned on manually.

Quick trouble shooting

Here are a few hints for network installation if things dont work as expected.

  1. Make sure a device is in factory reset state before including. In doubt exclude before include.
  2. If inclusion still fails, check if both devices use the same frequency.
  3. Remove all dead devices from associations. Otherwise you will see severe delays.
  4. Never use sleeping battery devices without a central controller.
  5. Dont poll FLIRS devices.
  6. Make sure to have enough mains powered device to benefit from the meshing

Configuration Parameters

Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.

IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.

Inclusion Information

If the controller is in inclusion mode, press one of the buttons three times

Exclusion Information

If the controller is in exclusion mode, press one of the buttons three times

Channels

The following table summarises the channels available for the ZME_05431 -:

Channel Name Channel ID Channel Type Category Item Type
Switch switch_binary switch_binary Switch Switch
Dimmer switch_dimmer switch_dimmer DimmableLight Dimmer
Scene Number scene_number scene_number Number
Electric meter (watts) meter_watts meter_watts Energy Number
Electric meter (kWh) meter_kwh meter_kwh Energy Number

Switch

Switch the power on and off.

The switch_binary channel is of type switch_binary and supports the Switch item and is in the Switch category.

Dimmer

The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.

The switch_dimmer channel is of type switch_dimmer and supports the Dimmer item and is in the DimmableLight category.

Scene Number

Triggers when a scene button is pressed.

The scene_number channel is of type scene_number and supports the Number item.

Electric meter (watts)

Indicates the instantaneous power consumption.

The meter_watts channel is of type meter_watts and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (kWh)

Indicates the energy consumption (kWh).

The meter_kwh channel is of type meter_kwh and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Device Configuration

The following table provides a summary of the 12 configuration parameters available in the ZME_05431. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Set LED indication mode
2 Automatic switch off If not zero, automatically switch off after a user defined time
3 Function of RF off command Defines how to interpret RF Off command.
4 Switch on/off by holding buttons Defines if the switch should change its state to on/off if being hold
5 Restore switch state after power cycle Defines if the switch should restore state to the last state
11 Invert buttons
12 Switch by buttons If disabled, the local operations by buttons will not switch the load
13 Action on button single press or hold Defines which command should be sent on button single press or hold
14 Action on button double press or hold Defines which command should be sent on button double press or press-hold
15 Send the following switch all commands
16 What to do on button Down press Defines hot to interprete button Down press.
20 Energy consumption Specify the consumption of the loads in watts (0=disabled)
Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Parameter 1: Set LED indication mode

The following option values may be configured -:

Value Description
0 Disabled
1 Show switch state
2 Night mode

The manufacturer defined default value is 1 (Show switch state).

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Parameter 2: Automatic switch off

If not zero, automatically switch off after a user defined time

Values in the range 0 to 65535 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_2_2 and is of type INTEGER.

Parameter 3: Function of RF off command

Defines how to interpret RF Off command. Defines how to interpret RF Off command. Can be used in conjunction with Auto Off function:

  • Ignore - to switch on the light by motion detectors and switch it off after some amount of time: in case of multiple motion detectors each would try to switch the light off that would break logics
  • Switch on - to switch on the light on both On and Off paddles press on the remote and switch it off after some amount of time. Button off click will still work (if button operations are not disabled) The following option values may be configured -:
Value Description
0 Switch off (default)
1 Ignore
2 Switch on
3 Switch on if load is off else switch off

The manufacturer defined default value is 0 (Switch off (default)).

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Parameter 4: Switch on/off by holding buttons

Defines if the switch should change its state to on/off if being hold Defines if the switch should change its state to on/off buttons if buttons are being hold The following option values may be configured -:

Value Description
0 No
1 Yes (default)

The manufacturer defined default value is 1 (Yes (default)).

This parameter has the configuration ID config_4_1 and is of type INTEGER.

Parameter 5: Restore switch state after power cycle

Defines if the switch should restore state to the last state Defines if the switch should restore switch  state to the last state prior to device power off (power cycle). The following option values may be configured -:

Value Description
0 No, turn off
1 Yes (default)

The manufacturer defined default value is 1 (Yes (default)).

This parameter has the configuration ID config_5_1 and is of type INTEGER.

Parameter 11: Invert buttons

The following option values may be configured -:

Value Description
0 No (default)
1 Yes

The manufacturer defined default value is 0 (No (default)).

This parameter has the configuration ID config_11_1 and is of type INTEGER.

Parameter 12: Switch by buttons

If disabled, the local operations by buttons will not switch the load If disabled, the local operations by buttons will not switch the load, but only send commands to On/Off association group. In this mode buttons are not linked with the switch anymore. They can be used separately: buttons to control remote device, switch will operate by RF commands only. The following option values may be configured -:

Value Description
0 No
1 By single press and hold (default)
2 By double press and press-hold

The manufacturer defined default value is 1 (By single press and hold (default)).

This parameter has the configuration ID config_12_1 and is of type INTEGER.

Parameter 13: Action on button single press or hold

Defines which command should be sent on button single press or hold Defines which command should be sent on button single press or hold. Basic commands are sent to Association group. Switch All commands are sent broadcast. The following option values may be configured -:

Value Description
0 Disabled
1 Switch On, Off and dim
2 Switch On, Off only (send Basic Set) (default)
3 Switch All
4 Send scenes
5 Send preconfigured scenes
6 Control devices in proximity
7 Control door lock
8 Control scene to gateway

The manufacturer defined default value is 2 (Switch On, Off only (send Basic Set) (default)).

This parameter has the configuration ID config_13_1 and is of type INTEGER.

Parameter 14: Action on button double press or hold

Defines which command should be sent on button double press or press-hold Defines which command should be sent on button double press or press-hold. Basic commands are sent to Association group. Switch All commands are sent broadcast. If not disabled, the device will wait for a click timeout to see if the second click would be pressed. This will introduce a small delay for single click commands. The following option values may be configured -:

Value Description
0 Disabled
1 Switch On, Off and dim
2 Switch On, Off only (send Basic Set) (default)
3 Switch All
4 Send scenes
5 Send preconfigured scenes
6 Control devices in proximity
7 Control door lock
8 Control scene to gateway

The manufacturer defined default value is 2 (Switch On, Off only (send Basic Set) (default)).

This parameter has the configuration ID config_14_1 and is of type INTEGER.

Parameter 15: Send the following switch all commands

The following option values may be configured -:

Value Description
1 Switch Off only (default)
2 Switch On only
255 Switch All on and off

The manufacturer defined default value is 1 (Switch Off only (default)).

This parameter has the configuration ID config_15_1 and is of type INTEGER.

Parameter 16: What to do on button Down press

Defines hot to interprete button Down press. Defines hot to interprete button Down press. Depends on parameters 12 and 32 "Switch by buttons" parameter. If not disabled this parameter will affect the action selected by the latter parameter. Can be used in conjunction with "Auto Off" function. The following option values may be configured -:

Value Description
0 Switch off (default)
1 Switch on if load is off else switch off
2 Switch on

The manufacturer defined default value is 0 (Switch off (default)).

This parameter has the configuration ID config_16_1 and is of type INTEGER.

Parameter 20: Energy consumption

Specify the consumption of the loads in watts (0=disabled) Specify the consumption of the loads in watts, for the calculation of power consumption. Max. load 1800 W. 0=disabled. The following option values may be configured, in addition to values in the range 0 to 1800 -:

Value Description
0 Disabled (default)

The manufacturer defined default value is 0 (Disabled (default)).

This parameter has the configuration ID config_20_2_wo and is of type INTEGER. This is a write only parameter.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -:

Value Description
0 Exclude from All On and All Off groups
1 Include in All On group
2 Include in All Off group
255 Include in All On and All Off groups

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The ZME_05431 supports 3 association groups.

Group 1: Lifeline

The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. Send reports on switch state change

Association group 1 supports 5 nodes.

Group 2: Single press

Single press and hold of up/down buttons

Association group 2 supports 5 nodes.

Group 3: Double press

Double press and hold of up/down buttons

Association group 3 supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC
COMMAND_CLASS_SWITCH_MULTILEVEL_V1
COMMAND_CLASS_SWITCH_ALL_V1
COMMAND_CLASS_SCENE_ACTIVATION_V1
COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1
COMMAND_CLASS_SCENE_CONTROLLER_CONF_V1
COMMAND_CLASS_METER_V3
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_PROTECTION_V1
COMMAND_CLASS_NODE_NAMING_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_VERSION_V2
COMMAND_CLASS_INDICATOR_V1
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V2

Documentation Links