Duwi Z-Wave Plugin Switch - ZWave |
{% include base.html %}
This describes the Z-Wave device Duwi Z-Wave Plugin Switch, manufactured by Reitz-Group.de with the thing type UID of reitz_duw064381_00_000
.
The Duwi Z-Wave Plugin Switch supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
No device information is provided in the database. Consider updating the database to improve the documentation.
The following table summarises the channels available for the Duwi Z-Wave Plugin Switch -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Switch | switch_binary | switch_binary | Switch | Switch |
Switch the power on and off.
The switch_binary
channel is of type switch_binary
and supports the Switch
item and is in the Switch
category.
The following table provides a summary of the 7 configuration parameters available in the Duwi Z-Wave Plugin Switch. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | LED indication mode | Set LED indication mode. |
2 | Automatically switch off after x seconds. | If not zero, automatically switch device off after a user defined time |
3 | What to do on RF off command. | Defines how to interpret RF Off-Command. |
5 | Restore switch state after power cycle. | Defines if the switch should restore switch state. |
20 | Specify the consumption of the load in watts | Maximum load 3500 Watts |
21 | LED Off color | Color for Off state. |
22 | LED On color. | Color for On state. |
Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands |
Set LED indication mode.
The following option values may be configured -:
Value | Description |
---|---|
0 | Disabled |
1 | Show switch state (default) |
2 | Operated by Indicator Command Class |
The manufacturer defined default value is 1
(Show switch state (default)).
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
If not zero, automatically switch device off after a user defined time If not zero, automatically switch device off after a user defined time.
- 0 -> Disabled
- 1 - 65535 -> Enabled, automatically switch off after x seconds. Values in the range 0 to 255 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_2_1
and is of type INTEGER
.
Defines how to interpret RF Off-Command. Can be used in conjunction with Auto Off function:
- Ignore – to switch on the light by motion detectors and switch it off after some amount of time: in case of multiple motion detectors each would try to switch the light off that would break logics;
- Switch on – to switch on the light on both ON and OFF paddle press on the remote and switch it off after some amount of time.
- Button OFF click will still work (if button operations are not disabled). The following option values may be configured -:
Value | Description |
---|---|
0 | Switch off (default) |
1 | Ignore |
2 | Switch on |
3 | Switch on if load is off, else switch off |
The manufacturer defined default value is 0
(Switch off (default)).
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
Defines if the switch should restore switch state. Defines if the switch should restore switch state to the last state prior to device power off (power cycle). The following option values may be configured -:
Value | Description |
---|---|
0 | No, turn off |
1 | Yes, default |
The manufacturer defined default value is 1
(Yes, default).
This parameter has the configuration ID config_5_1
and is of type INTEGER
.
Maximum load 3500 Watts Specify the consumption of the load in watts, for the calculation of power consumption:
- 0 -> Disabled
- 1 - 3500 -> Watts Values in the range 0 to 3500 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_20_2
and is of type INTEGER
.
Color for Off state.
The following option values may be configured -:
Value | Description |
---|---|
0 | Off |
1 | Red |
2 | Green |
3 | Blue |
4 | Yellow |
The manufacturer defined default value is 0
(Off).
This parameter has the configuration ID config_21_1
and is of type INTEGER
.
Color for On state.
The following option values may be configured -:
Value | Description |
---|---|
0 | Off |
1 | Red |
2 | Green |
3 | Blue |
4 | Yellow |
The manufacturer defined default value is 3
(Blue).
This parameter has the configuration ID config_22_1
and is of type INTEGER
.
Set the mode for the switch when receiving SWITCH ALL commands.
The following option values may be configured -:
Value | Description |
---|---|
0 | Exclude from All On and All Off groups |
1 | Include in All On group |
2 | Include in All Off group |
255 | Include in All On and All Off groups |
This parameter has the configuration ID switchall_mode
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The Duwi Z-Wave Plugin Switch supports 2 association groups.
Association group 1 supports 5 nodes.
Association group 2 supports 5 nodes.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_SWITCH_ALL_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_PROTECTION_V1 | |
COMMAND_CLASS_HAIL_V1 | |
COMMAND_CLASS_VERSION_V1 | |
COMMAND_CLASS_INDICATOR_V1 |