ZMNHID Flush on/off thermostat

This describes the Z-Wave device ZMNHID, manufactured by Goap with the thing type UID of qubino_zmnhid_00_000.

The device is in the category of HVAC, defining Air condition devices, Fans.

ZMNHID product image

The ZMNHID supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

This Z-Wave module is used to regulate temperature. The module can be controlled either  through Z-wave network  or  through  the wall switch.
The module is designed to be mounted inside a “flush  mounting box” and  is  hidden  behind a traditional wall switch.
Module measures power consumption of connected heating device

Inclusion Information

Module Inclusion (Adding to Z-Wave network)

  • Connect module to power supply
  • Enable add/remove mode on main controller
  • Auto inclusion   (works   for   about   5   seconds   after connected to power supply) or
  • Press service button S for more than 2 second or
  • Press  push  button  I1  three  times  within  3s  (3  times change switch state within 3 seconds).

NOTE1

For   auto inclusion   procedure,   first   set   main controller into inclusion mode and then connect module to power supply.

NOTE2

When  connecting  temperature  sensor  to  module that  has  already  been  included,  you  have  to  exclude module  first.
Switch  off  power supply,connect  the  sensor and re include the module.

Exclusion Information

Module    Exclusion/Reset    (Removing from Z-Wave network)

  • Connect module to power supply
  • Bring module within maximum 1 meter (3 feet) of  the main controller,
  • Enable add/remove mode on main controller press push button I1 five times within 3s (5 times change switch state within 3 seconds) in the first 60 seconds after the module is connected to the power supply or
  • Press  service  button S (only  applicable  for  24V SELV supply voltage) for more than 6 second.

By this function all parameters of the module are set to default values and own ID is deleted.
If push button I1 is pressed three times within 3s (or service button S is  pressed more than 2 and less than 6 seconds) module is excluded, but configuration parameters are not set to default values.

NOTE

If the module is included with parameters 100,101 or  102  with  values
different to default and module reset is done, wait at least 30s before next inclusion.

Channels

The following table summarises the channels available for the ZMNHID -:

Channel Name Channel ID Channel Type Category Item Type
Sensor (temperature) sensor_temperature sensor_temperature Temperature Number:Temperature
Electric meter (watts) meter_watts meter_watts Energy Number
Electric meter (kWh) meter_kwh meter_kwh Energy Number
Thermostat mode thermostat_mode thermostat_mode Temperature Number
Setpoint (heating) thermostat_setpoint thermostat_setpoint Heating Number:Temperature

Sensor (temperature)

Indicates the current temperature.

The sensor_temperature channel is of type sensor_temperature and supports the Number:Temperature item and is in the Temperature category.

Electric meter (watts)

Indicates the instantaneous power consumption.

The meter_watts channel is of type meter_watts and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (kWh)

Indicates the energy consumption (kWh).

The meter_kwh channel is of type meter_kwh and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Thermostat mode

Sets the thermostat.

The thermostat_mode channel is of type thermostat_mode and supports the Number item and is in the Temperature category. The following state translation is provided for this channel to the Number item type -:

Value Label
0 Off
1 Heat
2 Cool
3 Auto
4 Aux Heat
5 Resume
6 Fan Only
7 Furnace
8 Dry Air
9 Moist Air
10 Auto Changeover
11 Heat Economy
12 Cool Economy
13 Away

Setpoint (heating)

Sets the thermostat setpoint.

The thermostat_setpoint channel is of type thermostat_setpoint and supports the Number:Temperature item and is in the Heating category.

Device Configuration

The following table provides a summary of the 32 configuration parameters available in the ZMNHID. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Input 1 switch type Input 1 switch type
2 Input 2 switch type Input 2 switch type
3 Input 3 switch type Input 3 switch type
4 Input 1 contact type
5 Input 2 contact type
6 Parameter no. 6 Input 3 contact type
10 Parameter no. 10 Activate / deactivate functions ALL ON/ALL OFF
11 Parameter no. 11 I1 Functionality selection
12 Parameter no. 12 I2 Functionality selection
13 Parameter no. 13 I3 Functionality selection
40 Parameter no. 40 Power reporting in Watts on Power change
42 Parameter no. 42 Power reporting in Watts by time interval for Q1
43 Parameter no. 43 Hysteresis On
44 Parameter no. 44 Hysteresis Off
45 Parameter no. 45 Antifreeze
59 Parameter no. 59 Thermostat Mode
60 Parameter no. 60 Too low temperature limit
61 Parameter no. 61 Too high temperature limit
63 Parameter no. 63 Output Switch selection
70 Input 1 status on delay Switching reaction time on delay for I1
71 Input 1 status off delay Switching reaction time off delay for I1
72 Input 2 status on delay Switching reaction time on delay for I2
73 Input 2 status off delay Switching reaction time off delay for I2
74 Input 3 status on delay Switching reaction time on delay for I3
75 Input 3 status off delay Switching reaction time off delay for I3
100 Parameter no. 100 Enable / Disable Endpoint I1 or select Notification Type and Event
101 Parameter no. 101 Enable / Disable Endpoint I2 or select Notification Type and Event
102 Parameter no. 102 Enable / Disable Endpoint I3 or select Notification Type and Event
110 Parameter no. 110 Temperature sensor offset settings
120 Parameter no. 120 Digital temperature sensor reporting
121 Parameter no. 121 Digital temperature sensor / setpoint selector
122 Parameter no. 122 Node ID of external battery powered room sensor
Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Parameter 1: Input 1 switch type

Input 1 switch type

The following option values may be configured -:

Value Description
0 mono-stable switch type (push button)
1 bi-stable switch type

The manufacturer defined default value is 1 (bi-stable switch type).

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Parameter 2: Input 2 switch type

Input 2 switch type

The following option values may be configured -:

Value Description
0 mono-stable switch type (push button)
1 bi-stable switch type

The manufacturer defined default value is 1 (bi-stable switch type).

This parameter has the configuration ID config_2_1 and is of type INTEGER.

Parameter 3: Input 3 switch type

Input 3 switch type

The following option values may be configured -:

Value Description
0 mono-stable switch type (push button)
1 bi-stable switch type

The manufacturer defined default value is 1 (bi-stable switch type).

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Parameter 4: Input 1 contact type

The following option values may be configured -:

Value Description
0 NO (normally open) input type
1 NC (normally close) input type

The manufacturer defined default value is 0 (NO (normally open) input type).

This parameter has the configuration ID config_4_1 and is of type INTEGER.

Parameter 5: Input 2 contact type

The following option values may be configured -:

Value Description
0 NO (normally open) input type
1 NC (normally close) input type

The manufacturer defined default value is 0 (NO (normally open) input type).

This parameter has the configuration ID config_5_1 and is of type INTEGER.

Parameter 6: Parameter no. 6

Input 3 contact type See parameter 4 (valid for I3 instead of I1) The following option values may be configured -:

Value Description
0 NO (normally open) input type
1 NC (normally close) input type

The manufacturer defined default value is 0 (NO (normally open) input type).

This parameter has the configuration ID config_6_1 and is of type INTEGER.

Parameter 10: Parameter no. 10

Activate / deactivate functions ALL ON/ALL OFF Module responds to commands ALL ON / ALL OFF                 that may be sent by the main controller or by other controller belonging to the system. The following option values may be configured -:

Value Description
0 ALL ON is not active ALL OFF is not active
1 ALL ON is not active ALL OFF active
2 ALL ON active ALL OFF is not active
255 ALL ON active, ALL OFF active

The manufacturer defined default value is 255 (ALL ON active, ALL OFF active).

This parameter has the configuration ID config_10_2 and is of type INTEGER.

Parameter 11: Parameter no. 11

I1 Functionality selection Available config. parameters (data type is 2 Byte DEC):

  • Default value 1
  • 32767 – input  I1 doesn’t influence  on  the Heat/Cool process
  • 1 - input I1 changes the mode of the thermostat between Off  and Heat/Cool.In  this  case  function  on window sensor is disabled
  • 2 -input   I1   influences   on   heating/cooling valves according  to  status of window sensor. In  this  case function of Off and Heat/Cool selection by I1 is disabled. Values in the range 0 to 65535 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_11_2 and is of type INTEGER.

Parameter 12: Parameter no. 12

I2 Functionality selection Available config. parameters (data type is 2 Byte DEC):

  • Default value 32767
  • 32767 - input  I2 does  not  influence  on  the Heat/Cool process
  • From  0  to  990 - Temperature  set  point  from  0.0°C  to 99.0°C. When   I2   is   pressed,   it   automatically   set temperature setpoint according to value defined here. In this case function of condense sensor is disabled
  • From 1001 to 1150 - Temperature set point from -0.1°C to -15.0°C.
    When  I2  is  pressed,  it  automatically  set temperature setpoint according to value defined here. In this case function of condense sensor is disabled
  • 2000 - Input  I2  influences  on  the heating/cooling valve according  to status  of  condense  sensor,  In  this  case function of setpoint selection with I2 is disabled. Values in the range 0 to 65535 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_12_2 and is of type INTEGER.

Parameter 13: Parameter no. 13

I3 Functionality selection Available config. parameters (data type is 2 Byte DEC):

  • Default value 32767
  • 32767 - input  I3 does not influence on the Heat/Cool process
  • 1 - input I3 changes the mode of the thermostat between Heat and Cool and override  parameter  59.  In this case function on flood sensor is disabled
  • 2 - input  I3  influences  on  cooling and heating  valves according to status of flood sensor. In this case function of Heat and Cool selection by I3 is disabled. Values in the range 0 to 65535 may be set.

The manufacturer defined default value is 32767.

This parameter has the configuration ID config_13_2 and is of type INTEGER.

Parameter 40: Parameter no. 40

Power reporting in Watts on Power change 0 = Reporting Disabled

1–100 = 1% - 100% Reporting Enabled

Power report is sent (pushed) only when actual power in Watts in real time changed for more than set percentage comparing to previous actual power in Watts, step is 1%. Values in the range 0 to 255 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_40_1 and is of type INTEGER.

Parameter 42: Parameter no. 42

Power reporting in Watts by time interval for Q1 Set value means time interval (0 - 32767) in seconds when power is sent.

Available config. parameters:

default value is 0 (power report is disabled).

0 = Reporting Disabled

1–32767 = 1 second – 32767 seconds. Reporting enabled.

Power report is sent with time interval set by entered value. Values in the range 0 to 32767 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_42_2 and is of type INTEGER.

Parameter 43: Parameter no. 43

Hysteresis On This parameter defines temperature min difference between real measured temperature and set-point temperature to turn device on.

Available config. parameters (data type is 2 Byte DEC):
default value 1005 (-0.5 °C)
0 -127  =  0.0°C ~ 12.7 °C 
1001 -1127  =  -0.1°C ~ -12.7 °C Values in the range 0 to 65535 may be set.

The manufacturer defined default value is 1005.

This parameter has the configuration ID config_43_2 and is of type INTEGER.

Parameter 44: Parameter no. 44

Hysteresis Off This parameter defines temperature min difference between real measured temperature and set-point temperature to turn device off.

Available config. parameters (data type is 2 Byte DEC):
default value 5 (0.5 °C)
0 -127  =  0.0°C ~ 12.7 °C 
1001 -1127  =  -0.1°C ~ -12.7 °C Values in the range 0 to 65535 may be set.

The manufacturer defined default value is 5.

This parameter has the configuration ID config_44_2 and is of type INTEGER.

Parameter 45: Parameter no. 45

Antifreeze Set value means at which temperature the device will be turned on even if the thermostat was manually set to off.

Available config. parameters (data type is 2 Byte DEC):

  • default value 50(5.0 °C)
  • 0 -127  =  0.0°C ... 12.7 °C 
  • 1001 -1127  =  -0.1°C ~ -12.7 °C
  • 255 - Antifreeze functionality disabled Values in the range 0 to 65535 may be set.

The manufacturer defined default value is 50.

This parameter has the configuration ID config_45_2 and is of type INTEGER.

Parameter 59: Parameter no. 59

Thermostat Mode Available config. parameters (data type is 1 Byte DEC):
default value 0
0  - Heat mode
1 - Cool mode

NOTE:
After parameter change, first exclude module (without  setting  parameters to default value) and then re include the module! The following option values may be configured -:

Value Description
0 Heat Mode
1 Cool Mode

The manufacturer defined default value is 0 (Heat Mode).

This parameter has the configuration ID config_59_1 and is of type INTEGER.

Parameter 60: Parameter no. 60

Too low temperature limit Available config. parameters (data type is 2 Byte DEC):
default value 50 (Too low temperature limit is 5.0 °C)
1 -1000  =  0.1°C ~ 100.0 °C step is  0.1°C.
1001 -1150  =  -0.1°C ~ -15.0 °C

NOTE

Too low temperature limit is set by entered value. In case is set value out of this range, module is changing set value automatically to default value. Values in the range 0 to 65535 may be set.

The manufacturer defined default value is 50.

This parameter has the configuration ID config_60_2 and is of type INTEGER.

Parameter 61: Parameter no. 61

Too high temperature limit Available config. parameters (data type is 2 Byte DEC):
default value 700 (Too high temperature limit is 70.0 °C)
1 -1000  =  0.1°C ~ 100.0 °C step is  0.1°C.

NOTE

Too high temperature limit is set by entered value. In case is set value out of this range, module is changing set value automatically to default value. Values in the range 0 to 65535 may be set.

The manufacturer defined default value is 700.

This parameter has the configuration ID config_61_2 and is of type INTEGER.

Parameter 63: Parameter no. 63

Output Switch selection Set value means the type of the device that is connected to the on/off output. The  device  type  can  be  normally  open (NO) or normally close (NC).

Available config. parameters (data type is 1 Byte DEC):

  • default value 0
  • 0 - When system is turned off the output is 0 V.
  • 1 - When system is turned off the output is 230 V. The following option values may be configured -:
Value Description
0 When system is turned off the output is 0 V.
1 When system is turned off the output is 230 V.

The manufacturer defined default value is 0 (When system is turned off the output is 0 V.).

This parameter has the configuration ID config_63_1 and is of type INTEGER.

Parameter 70: Input 1 status on delay

Switching reaction time on delay for I1 If  the  value  of  parameter  is  different  to  0,  means  that the
Influence  of  this input  to  heating  or  cooling will  react  after inserted  time. This  parameter  has influence only when  the window sensor functionality is selected by the parameter no 11.

NOTE: Device status on UI change immediately Values in the range 0 to 32000 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_70_2 and is of type INTEGER.

Parameter 71: Input 1 status off delay

Switching reaction time off delay for I1 If the value of parameter is different to 0, means that the Influence of this input to heating or cooling will react after inserted time. This parameter has influence only when the window sensor functionality is selected by the parameter no 11.

NOTE

Device status on UI change immediately Values in the range 0 to 32000 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_71_2 and is of type INTEGER.

Parameter 72: Input 2 status on delay

Switching reaction time on delay for I2 See parameter 70 (valid for I2 instead of I1)
This parameter has influence  only  when  the  condense sensor functionality is selected by the parameter no12. Values in the range 0 to 32000 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_72_2 and is of type INTEGER.

Parameter 73: Input 2 status off delay

Switching reaction time off delay for I2 See parameter 71 (valid for I2 instead of I1)
This  parameter  has  influence  only  when  the  condense sensor functionality is selected by the parameter no12. Values in the range 0 to 32000 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_73_2 and is of type INTEGER.

Parameter 74: Input 3 status on delay

Switching reaction time on delay for I3 See parameter 70 (valid for I2 instead of I1)
This parameter has influence  only  when  the  condense sensor functionality is selected by the parameter no13. Values in the range 0 to 32000 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_74_2 and is of type INTEGER.

Parameter 75: Input 3 status off delay

Switching reaction time off delay for I3 See parameter 71 (valid for I2 instead of I1)
This  parameter  has  influence  only  when  the  condense sensor functionality is selected by the parameter no13. Values in the range 0 to 32000 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_75_2 and is of type INTEGER.

Parameter 100: Parameter no. 100

Enable / Disable Endpoint I1 or select Notification Type and Event Enabling I1 means that Endpoint (I1) will be present on UI.
Disabling it will result in hiding the endpoint according to the parameter set value. Additionally, a Notification Type and Event can be selected for the endpoint. Available configuration parameters (data type is 1 Byte DEC):
Endpoint device type selection:
notification sensor (1 -6):
GENERIC_TYPE_SENSOR_NOTIFICATION,
SPECIFIC_TYPE_NOTIFICATION_SENSOR
default value 0
1 - Home Security; Motion Detection,unknown location.
2 - CO; Carbon Monoxide detected, unknown location.
3 - CO2; Carbon Dioxide detected, unknown location.
4 - W ater Alarm; Water Leak detected, unknown location.
5 - Heat Alarm; Overheat detected, unknown location.
6 - Smoke Alarm; Smoke detected, unknown location.
0 - Endpoint, I1 disabled

  • sensor binary (9):
    GENERIC_TYPE_SENSOR_BINARY,
    SPECIFIC_TYPE_NOT_USED
    9 - Sensor binary
    NOTE1:
    After   parameter  change,   first   exclude  module (without  setting parameters  to default  value)  and  then  re include the module!
    NOTE2:  
    When the parameter is set to value 9 the notifications are send for Home Security. Values in the range 0 to 255 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_100_1 and is of type INTEGER.

Parameter 101: Parameter no. 101

Enable / Disable Endpoint I2 or select Notification Type and Event See parameter 100 (valid for I2 instead of I1) Values in the range 0 to 255 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_101_1 and is of type INTEGER.

Parameter 102: Parameter no. 102

Enable / Disable Endpoint I3 or select Notification Type and Event See parameter 100 (valid for I3 instead of I1) Values in the range 0 to 255 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_102_1 and is of type INTEGER.

Parameter 110: Parameter no. 110

Temperature sensor offset settings Set value result in adding or subtracting that value to actual measured value by sensor.

Available config. parameters (data type is 2 Byte DEC):

  • default value 32536
  • 32536 – offset is 0.0°C
  • From 1 to 100 – value from 0.1 °C to 10.0 °C is added to actual measured temperature.
  • From  1001  to  1100 –value  from -0.1  °C  to -10.0  °C  is subtracted to actual measured temperature. Values in the range 0 to 65535 may be set.

The manufacturer defined default value is 32536.

This parameter has the configuration ID config_110_2 and is of type INTEGER.

Parameter 120: Parameter no. 120

Digital temperature sensor reporting If digital temperature sensor is connected, module reports measured  temperature on temperature change defined by this parameter.

Available config. parameters (data type is 1 Byte DEC):

  • default value 5
  • 0 –Reporting disabled
  • 1 -127 = 0.1°C – 12.7°C, step is 0.1°C Values in the range 0 to 127 may be set.

The manufacturer defined default value is 5.

This parameter has the configuration ID config_120_1 and is of type INTEGER.

Parameter 121: Parameter no. 121

Digital temperature sensor / setpoint selector If  digital  temperature  sensor is not connected, module can grab measured   temperature from   external   secondary module.

Available config. parameters (data type is 1 Byte DEC):
Default value 0

0 - Internal   digital   temperature   sensor   is   mounted, setpoint is set by controller

1 - (bit  0) temperature  is  grabbed  from  external  always on sensor with sensor_multilevel_get sent by association 3

2 - (bit  1) temperature  is  grabbed  from  external  battery powered room sensor declared in parameter 122

4 - (bit  2) setpoint  is  gragged  from  external  always  on module with thermostat_setpoint_get sent by association 5 

8 - (bit  3) setpoint  is  grabbed  from  external  battery powered room sensor declared in parameter 122.

10 – (bit  1  and  bit  3) temperature  AND  setpoint  are grabbed  from external  battery  powered  room  sensor declared in parameter 122 Values in the range 0 to 255 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_121_1 and is of type INTEGER.

Parameter 122: Parameter no. 122

Node ID of external battery powered room sensor If  digital  temperature  sensor is not connected, module can grab measured temperature from external battery powered room sensor defined by this parameter.

Available config. parameters (data type is 1 Byte DEC):

Default value 0

0 – external battery powered room sensor not in function

1 -254 = Node  ID  of  external  battery  powered  room sensor

NOTE:  

Get sensor Node ID from controller and set parameter 122 immediately  after  sensor  weak  up  (after button press on it etc.) Values in the range 0 to 254 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_122_1 and is of type INTEGER.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -:

Value Description
0 Exclude from All On and All Off groups
1 Include in All On group
2 Include in All Off group
255 Include in All On and All Off groups

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The ZMNHID supports 6 association groups.

Group 1: Basic on/off Q1

Association group 1 supports 16 nodes.

Group 2: Basic on/off I2

Association group 2 supports 16 nodes.

Group 3: Basic on/off I3

Association group 3 supports 16 nodes.

Group 4: High Temperature

Association group 4 supports 16 nodes.

Group 5: Low Temperature

Association group 5 supports 16 nodes.

Group 6: Default Reporting Group

Association group 6 supports 1 node.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_ALL_V1
COMMAND_CLASS_SENSOR_MULTILEVEL_V5
COMMAND_CLASS_METER_V3
COMMAND_CLASS_THERMOSTAT_MODE_V2
COMMAND_CLASS_THERMOSTAT_SETPOINT_V2
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_ASSOCIATION_V1
COMMAND_CLASS_VERSION_V1

Documentation Links