This describes the Z-Wave device ZMNHID, manufactured by Goap with the thing type UID of qubino_zmnhid_00_000
.
The device is in the category of HVAC, defining Air condition devices, Fans.
The ZMNHID supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
This Z-Wave module is used to regulate temperature. The module can be controlled either through Z-wave network or through the wall switch.
The module is designed to be mounted inside a “flush mounting box” and is hidden behind a traditional wall switch.
Module measures power consumption of connected heating device
Module Inclusion (Adding to Z-Wave network)
- Connect module to power supply
- Enable add/remove mode on main controller
- Auto inclusion (works for about 5 seconds after connected to power supply) or
- Press service button S for more than 2 second or
- Press push button I1 three times within 3s (3 times change switch state within 3 seconds).
NOTE1
For auto inclusion procedure, first set main controller into inclusion mode and then connect module to power supply.
NOTE2
When connecting temperature sensor to module that has already been included, you have to exclude module first.
Switch off power supply,connect the sensor and re include the module.
Module Exclusion/Reset (Removing from Z-Wave network)
- Connect module to power supply
- Bring module within maximum 1 meter (3 feet) of the main controller,
- Enable add/remove mode on main controller press push button I1 five times within 3s (5 times change switch state within 3 seconds) in the first 60 seconds after the module is connected to the power supply or
- Press service button S (only applicable for 24V SELV supply voltage) for more than 6 second.
By this function all parameters of the module are set to default values and own ID is deleted.
If push button I1 is pressed three times within 3s (or service button S is pressed more than 2 and less than 6 seconds) module is excluded, but configuration parameters are not set to default values.
NOTE
If the module is included with parameters 100,101 or 102 with values
different to default and module reset is done, wait at least 30s before next inclusion.
The following table summarises the channels available for the ZMNHID -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Sensor (temperature) | sensor_temperature | sensor_temperature | Temperature | Number:Temperature |
Electric meter (watts) | meter_watts | meter_watts | Energy | Number |
Electric meter (kWh) | meter_kwh | meter_kwh | Energy | Number |
Thermostat mode | thermostat_mode | thermostat_mode | Temperature | Number |
Setpoint (heating) | thermostat_setpoint | thermostat_setpoint | Heating | Number:Temperature |
Indicates the current temperature.
The sensor_temperature
channel is of type sensor_temperature
and supports the Number:Temperature
item and is in the Temperature
category.
Indicates the instantaneous power consumption.
The meter_watts
channel is of type meter_watts
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the energy consumption (kWh).
The meter_kwh
channel is of type meter_kwh
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Sets the thermostat.
The thermostat_mode
channel is of type thermostat_mode
and supports the Number
item and is in the Temperature
category.
The following state translation is provided for this channel to the Number
item type -:
Value | Label |
---|---|
0 | Off |
1 | Heat |
2 | Cool |
3 | Auto |
4 | Aux Heat |
5 | Resume |
6 | Fan Only |
7 | Furnace |
8 | Dry Air |
9 | Moist Air |
10 | Auto Changeover |
11 | Heat Economy |
12 | Cool Economy |
13 | Away |
Sets the thermostat setpoint.
The thermostat_setpoint
channel is of type thermostat_setpoint
and supports the Number:Temperature
item and is in the Heating
category.
The following table provides a summary of the 32 configuration parameters available in the ZMNHID. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Input 1 switch type | Input 1 switch type |
2 | Input 2 switch type | Input 2 switch type |
3 | Input 3 switch type | Input 3 switch type |
4 | Input 1 contact type | |
5 | Input 2 contact type | |
6 | Parameter no. 6 | Input 3 contact type |
10 | Parameter no. 10 | Activate / deactivate functions ALL ON/ALL OFF |
11 | Parameter no. 11 | I1 Functionality selection |
12 | Parameter no. 12 | I2 Functionality selection |
13 | Parameter no. 13 | I3 Functionality selection |
40 | Parameter no. 40 | Power reporting in Watts on Power change |
42 | Parameter no. 42 | Power reporting in Watts by time interval for Q1 |
43 | Parameter no. 43 | Hysteresis On |
44 | Parameter no. 44 | Hysteresis Off |
45 | Parameter no. 45 | Antifreeze |
59 | Parameter no. 59 | Thermostat Mode |
60 | Parameter no. 60 | Too low temperature limit |
61 | Parameter no. 61 | Too high temperature limit |
63 | Parameter no. 63 | Output Switch selection |
70 | Input 1 status on delay | Switching reaction time on delay for I1 |
71 | Input 1 status off delay | Switching reaction time off delay for I1 |
72 | Input 2 status on delay | Switching reaction time on delay for I2 |
73 | Input 2 status off delay | Switching reaction time off delay for I2 |
74 | Input 3 status on delay | Switching reaction time on delay for I3 |
75 | Input 3 status off delay | Switching reaction time off delay for I3 |
100 | Parameter no. 100 | Enable / Disable Endpoint I1 or select Notification Type and Event |
101 | Parameter no. 101 | Enable / Disable Endpoint I2 or select Notification Type and Event |
102 | Parameter no. 102 | Enable / Disable Endpoint I3 or select Notification Type and Event |
110 | Parameter no. 110 | Temperature sensor offset settings |
120 | Parameter no. 120 | Digital temperature sensor reporting |
121 | Parameter no. 121 | Digital temperature sensor / setpoint selector |
122 | Parameter no. 122 | Node ID of external battery powered room sensor |
Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands |
Input 1 switch type
The following option values may be configured -:
Value | Description |
---|---|
0 | mono-stable switch type (push button) |
1 | bi-stable switch type |
The manufacturer defined default value is 1
(bi-stable switch type).
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
Input 2 switch type
The following option values may be configured -:
Value | Description |
---|---|
0 | mono-stable switch type (push button) |
1 | bi-stable switch type |
The manufacturer defined default value is 1
(bi-stable switch type).
This parameter has the configuration ID config_2_1
and is of type INTEGER
.
Input 3 switch type
The following option values may be configured -:
Value | Description |
---|---|
0 | mono-stable switch type (push button) |
1 | bi-stable switch type |
The manufacturer defined default value is 1
(bi-stable switch type).
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
The following option values may be configured -:
Value | Description |
---|---|
0 | NO (normally open) input type |
1 | NC (normally close) input type |
The manufacturer defined default value is 0
(NO (normally open) input type).
This parameter has the configuration ID config_4_1
and is of type INTEGER
.
The following option values may be configured -:
Value | Description |
---|---|
0 | NO (normally open) input type |
1 | NC (normally close) input type |
The manufacturer defined default value is 0
(NO (normally open) input type).
This parameter has the configuration ID config_5_1
and is of type INTEGER
.
Input 3 contact type See parameter 4 (valid for I3 instead of I1) The following option values may be configured -:
Value | Description |
---|---|
0 | NO (normally open) input type |
1 | NC (normally close) input type |
The manufacturer defined default value is 0
(NO (normally open) input type).
This parameter has the configuration ID config_6_1
and is of type INTEGER
.
Activate / deactivate functions ALL ON/ALL OFF Module responds to commands ALL ON / ALL OFF that may be sent by the main controller or by other controller belonging to the system. The following option values may be configured -:
Value | Description |
---|---|
0 | ALL ON is not active ALL OFF is not active |
1 | ALL ON is not active ALL OFF active |
2 | ALL ON active ALL OFF is not active |
255 | ALL ON active, ALL OFF active |
The manufacturer defined default value is 255
(ALL ON active, ALL OFF active).
This parameter has the configuration ID config_10_2
and is of type INTEGER
.
I1 Functionality selection Available config. parameters (data type is 2 Byte DEC):
- Default value 1
- 32767 – input I1 doesn’t influence on the Heat/Cool process
- 1 - input I1 changes the mode of the thermostat between Off and Heat/Cool.In this case function on window sensor is disabled
- 2 -input I1 influences on heating/cooling valves according to status of window sensor. In this case function of Off and Heat/Cool selection by I1 is disabled. Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_11_2
and is of type INTEGER
.
I2 Functionality selection Available config. parameters (data type is 2 Byte DEC):
- Default value 32767
- 32767 - input I2 does not influence on the Heat/Cool process
- From 0 to 990 - Temperature set point from 0.0°C to 99.0°C. When I2 is pressed, it automatically set temperature setpoint according to value defined here. In this case function of condense sensor is disabled
- From 1001 to 1150 - Temperature set point from -0.1°C to -15.0°C.
When I2 is pressed, it automatically set temperature setpoint according to value defined here. In this case function of condense sensor is disabled - 2000 - Input I2 influences on the heating/cooling valve according to status of condense sensor, In this case function of setpoint selection with I2 is disabled. Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_12_2
and is of type INTEGER
.
I3 Functionality selection Available config. parameters (data type is 2 Byte DEC):
- Default value 32767
- 32767 - input I3 does not influence on the Heat/Cool process
- 1 - input I3 changes the mode of the thermostat between Heat and Cool and override parameter 59. In this case function on flood sensor is disabled
- 2 - input I3 influences on cooling and heating valves according to status of flood sensor. In this case function of Heat and Cool selection by I3 is disabled. Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 32767
.
This parameter has the configuration ID config_13_2
and is of type INTEGER
.
Power reporting in Watts on Power change 0 = Reporting Disabled
1–100 = 1% - 100% Reporting Enabled
Power report is sent (pushed) only when actual power in Watts in real time changed for more than set percentage comparing to previous actual power in Watts, step is 1%. Values in the range 0 to 255 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_40_1
and is of type INTEGER
.
Power reporting in Watts by time interval for Q1 Set value means time interval (0 - 32767) in seconds when power is sent.
Available config. parameters:
default value is 0 (power report is disabled).
0 = Reporting Disabled
1–32767 = 1 second – 32767 seconds. Reporting enabled.
Power report is sent with time interval set by entered value. Values in the range 0 to 32767 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_42_2
and is of type INTEGER
.
Hysteresis On This parameter defines temperature min difference between real measured temperature and set-point temperature to turn device on.
Available config. parameters (data type is 2 Byte DEC):
default value 1005 (-0.5 °C)
0 -127 = 0.0°C ~ 12.7 °C
1001 -1127 = -0.1°C ~ -12.7 °C
Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 1005
.
This parameter has the configuration ID config_43_2
and is of type INTEGER
.
Hysteresis Off This parameter defines temperature min difference between real measured temperature and set-point temperature to turn device off.
Available config. parameters (data type is 2 Byte DEC):
default value 5 (0.5 °C)
0 -127 = 0.0°C ~ 12.7 °C
1001 -1127 = -0.1°C ~ -12.7 °C
Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 5
.
This parameter has the configuration ID config_44_2
and is of type INTEGER
.
Antifreeze Set value means at which temperature the device will be turned on even if the thermostat was manually set to off.
Available config. parameters (data type is 2 Byte DEC):
- default value 50(5.0 °C)
- 0 -127 = 0.0°C ... 12.7 °C
- 1001 -1127 = -0.1°C ~ -12.7 °C
- 255 - Antifreeze functionality disabled Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 50
.
This parameter has the configuration ID config_45_2
and is of type INTEGER
.
Thermostat Mode
Available config. parameters (data type is 1 Byte DEC):
default value 0
0 - Heat mode
1 - Cool mode
NOTE:
After parameter change, first exclude module (without setting parameters to default value) and then re include the module!
The following option values may be configured -:
Value | Description |
---|---|
0 | Heat Mode |
1 | Cool Mode |
The manufacturer defined default value is 0
(Heat Mode).
This parameter has the configuration ID config_59_1
and is of type INTEGER
.
Too low temperature limit
Available config. parameters (data type is 2 Byte DEC):
default value 50 (Too low temperature limit is 5.0 °C)
1 -1000 = 0.1°C ~ 100.0 °C step is 0.1°C.
1001 -1150 = -0.1°C ~ -15.0 °C
NOTE
Too low temperature limit is set by entered value. In case is set value out of this range, module is changing set value automatically to default value. Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 50
.
This parameter has the configuration ID config_60_2
and is of type INTEGER
.
Too high temperature limit
Available config. parameters (data type is 2 Byte DEC):
default value 700 (Too high temperature limit is 70.0 °C)
1 -1000 = 0.1°C ~ 100.0 °C step is 0.1°C.
NOTE
Too high temperature limit is set by entered value. In case is set value out of this range, module is changing set value automatically to default value. Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 700
.
This parameter has the configuration ID config_61_2
and is of type INTEGER
.
Output Switch selection Set value means the type of the device that is connected to the on/off output. The device type can be normally open (NO) or normally close (NC).
Available config. parameters (data type is 1 Byte DEC):
- default value 0
- 0 - When system is turned off the output is 0 V.
- 1 - When system is turned off the output is 230 V. The following option values may be configured -:
Value | Description |
---|---|
0 | When system is turned off the output is 0 V. |
1 | When system is turned off the output is 230 V. |
The manufacturer defined default value is 0
(When system is turned off the output is 0 V.).
This parameter has the configuration ID config_63_1
and is of type INTEGER
.
Switching reaction time on delay for I1
If the value of parameter is different to 0, means that the
Influence of this input to heating or cooling will react after inserted time. This parameter has influence only when the window sensor functionality is selected by the parameter no 11.
NOTE: Device status on UI change immediately Values in the range 0 to 32000 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_70_2
and is of type INTEGER
.
Switching reaction time off delay for I1 If the value of parameter is different to 0, means that the Influence of this input to heating or cooling will react after inserted time. This parameter has influence only when the window sensor functionality is selected by the parameter no 11.
NOTE
Device status on UI change immediately Values in the range 0 to 32000 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_71_2
and is of type INTEGER
.
Switching reaction time on delay for I2
See parameter 70 (valid for I2 instead of I1)
This parameter has influence only when the condense sensor functionality is selected by the parameter no12.
Values in the range 0 to 32000 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_72_2
and is of type INTEGER
.
Switching reaction time off delay for I2
See parameter 71 (valid for I2 instead of I1)
This parameter has influence only when the condense sensor functionality is selected by the parameter no12.
Values in the range 0 to 32000 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_73_2
and is of type INTEGER
.
Switching reaction time on delay for I3
See parameter 70 (valid for I2 instead of I1)
This parameter has influence only when the condense sensor functionality is selected by the parameter no13.
Values in the range 0 to 32000 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_74_2
and is of type INTEGER
.
Switching reaction time off delay for I3
See parameter 71 (valid for I2 instead of I1)
This parameter has influence only when the condense sensor functionality is selected by the parameter no13.
Values in the range 0 to 32000 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_75_2
and is of type INTEGER
.
Enable / Disable Endpoint I1 or select Notification Type and Event
Enabling I1 means that Endpoint (I1) will be present on UI.
Disabling it will result in hiding the endpoint according to the parameter set value. Additionally, a Notification Type and Event can be selected for the endpoint. Available configuration parameters (data type is 1 Byte DEC):
Endpoint device type selection:
notification sensor (1 -6):
GENERIC_TYPE_SENSOR_NOTIFICATION,
SPECIFIC_TYPE_NOTIFICATION_SENSOR
default value 0
1 - Home Security; Motion Detection,unknown location.
2 - CO; Carbon Monoxide detected, unknown location.
3 - CO2; Carbon Dioxide detected, unknown location.
4 - W ater Alarm; Water Leak detected, unknown location.
5 - Heat Alarm; Overheat detected, unknown location.
6 - Smoke Alarm; Smoke detected, unknown location.
0 - Endpoint, I1 disabled
- sensor binary (9):
GENERIC_TYPE_SENSOR_BINARY,
SPECIFIC_TYPE_NOT_USED
9 - Sensor binary
NOTE1:
After parameter change, first exclude module (without setting parameters to default value) and then re include the module!
NOTE2:
When the parameter is set to value 9 the notifications are send for Home Security. Values in the range 0 to 255 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_100_1
and is of type INTEGER
.
Enable / Disable Endpoint I2 or select Notification Type and Event See parameter 100 (valid for I2 instead of I1) Values in the range 0 to 255 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_101_1
and is of type INTEGER
.
Enable / Disable Endpoint I3 or select Notification Type and Event See parameter 100 (valid for I3 instead of I1) Values in the range 0 to 255 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_102_1
and is of type INTEGER
.
Temperature sensor offset settings Set value result in adding or subtracting that value to actual measured value by sensor.
Available config. parameters (data type is 2 Byte DEC):
- default value 32536
- 32536 – offset is 0.0°C
- From 1 to 100 – value from 0.1 °C to 10.0 °C is added to actual measured temperature.
- From 1001 to 1100 –value from -0.1 °C to -10.0 °C is subtracted to actual measured temperature. Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 32536
.
This parameter has the configuration ID config_110_2
and is of type INTEGER
.
Digital temperature sensor reporting If digital temperature sensor is connected, module reports measured temperature on temperature change defined by this parameter.
Available config. parameters (data type is 1 Byte DEC):
- default value 5
- 0 –Reporting disabled
- 1 -127 = 0.1°C – 12.7°C, step is 0.1°C Values in the range 0 to 127 may be set.
The manufacturer defined default value is 5
.
This parameter has the configuration ID config_120_1
and is of type INTEGER
.
Digital temperature sensor / setpoint selector If digital temperature sensor is not connected, module can grab measured temperature from external secondary module.
Available config. parameters (data type is 1 Byte DEC):
Default value 0
0 - Internal digital temperature sensor is mounted, setpoint is set by controller
1 - (bit 0) temperature is grabbed from external always on sensor with sensor_multilevel_get sent by association 3
2 - (bit 1) temperature is grabbed from external battery powered room sensor declared in parameter 122
4 - (bit 2) setpoint is gragged from external always on module with thermostat_setpoint_get sent by association 5
8 - (bit 3) setpoint is grabbed from external battery powered room sensor declared in parameter 122.
10 – (bit 1 and bit 3) temperature AND setpoint are grabbed from external battery powered room sensor declared in parameter 122 Values in the range 0 to 255 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_121_1
and is of type INTEGER
.
Node ID of external battery powered room sensor If digital temperature sensor is not connected, module can grab measured temperature from external battery powered room sensor defined by this parameter.
Available config. parameters (data type is 1 Byte DEC):
Default value 0
0 – external battery powered room sensor not in function
1 -254 = Node ID of external battery powered room sensor
NOTE:
Get sensor Node ID from controller and set parameter 122 immediately after sensor weak up (after button press on it etc.) Values in the range 0 to 254 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_122_1
and is of type INTEGER
.
Set the mode for the switch when receiving SWITCH ALL commands.
The following option values may be configured -:
Value | Description |
---|---|
0 | Exclude from All On and All Off groups |
1 | Include in All On group |
2 | Include in All Off group |
255 | Include in All On and All Off groups |
This parameter has the configuration ID switchall_mode
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The ZMNHID supports 6 association groups.
Association group 1 supports 16 nodes.
Association group 2 supports 16 nodes.
Association group 3 supports 16 nodes.
Association group 4 supports 16 nodes.
Association group 5 supports 16 nodes.
Association group 6 supports 1 node.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_ALL_V1 | |
COMMAND_CLASS_SENSOR_MULTILEVEL_V5 | |
COMMAND_CLASS_METER_V3 | |
COMMAND_CLASS_THERMOSTAT_MODE_V2 | |
COMMAND_CLASS_THERMOSTAT_SETPOINT_V2 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_ASSOCIATION_V1 | |
COMMAND_CLASS_VERSION_V1 |