ZMNHIA Flush on/off thermostat

This describes the Z-Wave device ZMNHIA, manufactured by Goap with the thing type UID of qubino_zmnhia_00_000.

The device is in the category of HVAC, defining Air condition devices, Fans.

ZMNHIA product image

The ZMNHIA supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

This Z-Wave module is used to regulate temperature. The module can be controlled either through Z-wave network or through the wall switch

Inclusion Information

  • press service button S for more than 2 second or
  • press push button I1 three times within 3s (3 times change switch state within 3 seconds

Exclusion Information

  • press service button S for more than 6 second or
  • press push button I1 five times within 3s (5 times change switch state within 3 seconds).

Channels

The following table summarises the channels available for the ZMNHIA -:

Channel Name Channel ID Channel Type Category Item Type
Sensor (temperature) sensor_temperature sensor_temperature Temperature Number:Temperature
Electric meter (watts) meter_watts meter_watts Energy Number
Electric meter (kWh) meter_kwh meter_kwh Energy Number
Thermostat mode thermostat_mode thermostat_mode Temperature Number
Setpoint (heating) thermostat_setpoint thermostat_setpoint Heating Number:Temperature
Binary Sensor 1 sensor_binary1 sensor_binary Switch
Binary Sensor 2 sensor_binary2 sensor_binary Switch

Sensor (temperature)

Indicates the current temperature.

The sensor_temperature channel is of type sensor_temperature and supports the Number:Temperature item and is in the Temperature category.

Electric meter (watts)

Indicates the instantaneous power consumption.

The meter_watts channel is of type meter_watts and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (kWh)

Indicates the energy consumption (kWh).

The meter_kwh channel is of type meter_kwh and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Thermostat mode

Sets the thermostat.

The thermostat_mode channel is of type thermostat_mode and supports the Number item and is in the Temperature category. The following state translation is provided for this channel to the Number item type -:

Value Label
0 Off
1 Heat
2 Cool
3 Auto
4 Aux Heat
5 Resume
6 Fan Only
7 Furnace
8 Dry Air
9 Moist Air
10 Auto Changeover
11 Heat Economy
12 Cool Economy
13 Away

Setpoint (heating)

Sets the thermostat setpoint.

The thermostat_setpoint channel is of type thermostat_setpoint and supports the Number:Temperature item and is in the Heating category.

Binary Sensor 1

Indicates if a sensor has triggered.

The sensor_binary1 channel is of type sensor_binary and supports the Switch item. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
ON Triggered
OFF Untriggered

Binary Sensor 2

Indicates if a sensor has triggered.

The sensor_binary2 channel is of type sensor_binary and supports the Switch item. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
ON Triggered
OFF Untriggered

Device Configuration

The following table provides a summary of the 17 configuration parameters available in the ZMNHIA. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Input 1 switch type Input 1 switch type
2 Input 2 switch type Input 2 switch type
3 Input 3 switch type Input 3 switch type
4 Input 2 contact type
5 Input 3 contact type
10 Activate / deactivate functions ALL ON/ALL OFF Module responds to commands ALL ON / ALL OFF
11 Set point set by I2 Set point set by I2
12 Set point set by I3 Set point set by I3
30 Saving the state after a power failure Saving the state after a power failure
40 Power reporting in Watts on power change for Q1 Power reporting in Watts on power change
42 Power reporting in Watts by time interval for Q1 Power reporting in Watts by time interval
43 Hysteresis On Hysteresis On
44 Hysteresis Off Hysteresis Off
45 Antifreeze Antifreeze function Temperature
60 Too low temperature limit Too low temperature limit
61 Too high temperature limit Too high temperature limit
63 Switch selection Connected device type can be (NO) or (NC)

Parameter 1: Input 1 switch type

Input 1 switch type

The following option values may be configured -:

Value Description
0 mono-stable switch type (push button)
1 bi-stable switch type

The manufacturer defined default value is 1 (bi-stable switch type).

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Parameter 2: Input 2 switch type

Input 2 switch type

The following option values may be configured -:

Value Description
0 mono-stable switch type (push button)
1 bi-stable switch type

The manufacturer defined default value is 1 (bi-stable switch type).

This parameter has the configuration ID config_2_1 and is of type INTEGER.

Parameter 3: Input 3 switch type

Input 3 switch type

The following option values may be configured -:

Value Description
0 mono-stable switch type (push button)
1 bi-stable switch type

The manufacturer defined default value is 1 (bi-stable switch type).

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Parameter 4: Input 2 contact type

The following option values may be configured -:

Value Description
0 NO (normally open) input type
1 NC (normally close) input type

The manufacturer defined default value is 0 (NO (normally open) input type).

This parameter has the configuration ID config_4_1 and is of type INTEGER.

Parameter 5: Input 3 contact type

The following option values may be configured -:

Value Description
0 NO (normally open) input type
1 NC (normally close) input type

The manufacturer defined default value is 0 (NO (normally open) input type).

This parameter has the configuration ID config_5_1 and is of type INTEGER.

Parameter 10: Activate / deactivate functions ALL ON/ALL OFF

Module responds to commands ALL ON / ALL OFF Module responds to commands ALL ON / ALL OFF that may be sent by the main controller or by other controller belonging to the system. The following option values may be configured -:

Value Description
0 ALL ON is not active ALL OFF is not active
1 ALL ON is not active ALL OFF active
2 ALL ON active ALL OFF is not active
255 ALL ON active, ALL OFF active

The manufacturer defined default value is 255 (ALL ON active, ALL OFF active).

This parameter has the configuration ID config_10_1 and is of type INTEGER.

Parameter 11: Set point set by I2

Set point set by I2 When I2 is pressed set point will be set according to the value of this parameter. Available config. parameters:

default value 65535

65535 – input I2 does not influence on the set point

From 0 to 990 – set point from 0.0 °C to 99.0 °C

From 1001 to 1150 – set point from -0.1 °C to -15.0 °C Values in the range 0 to 65535 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_11_2 and is of type INTEGER.

Parameter 12: Set point set by I3

Set point set by I3 When I3 is pressed set point will be set according to the value of this parameter. Available config. parameters

default value 65535

65535 – input I3 does not influence on the set point

From 0 to 990 – set point from 0.0 °C to 99.0 °C

From 1001 to 1150 – set point from -0.1 °C to -15.0 °C Values in the range 0 to 65535 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_12_2 and is of type INTEGER.

Parameter 30: Saving the state after a power failure

Saving the state after a power failure

The following option values may be configured -:

Value Description
0 Module saves its state
1 Module does not save state

The manufacturer defined default value is 0 (Module saves its state).

This parameter has the configuration ID config_30_1 and is of type INTEGER.

Parameter 40: Power reporting in Watts on power change for Q1

Power reporting in Watts on power change Set value means percentage, set value from 0 - 100=0% - 100%. Available configuration parameters

default value 3

0 – Reporting Disabled

1–100 = 1%-100% Reporting enabled. Power report is sent (push) only when actual power in Watts in real time changes for more than set percentage comparing to previous actual power in Watts, step is 1%.

NOTE: If power changed is less than 1W, the report is not sent (pushed), independent of percentage set. Values in the range 0 to 255 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_40_1 and is of type INTEGER.

Parameter 42: Power reporting in Watts by time interval for Q1

Power reporting in Watts by time interval Set value means time interval (0 – 65535) in seconds, when power report is send. Available config. parameters

default value 300 (power report in Watts is send each 300s)

0 – Reporting Disabled

1 – 65535 = 1second – 65535 seconds. Reporting enabled. Power report is send with time interval set by entered value. Values in the range 0 to 65535 may be set.

The manufacturer defined default value is 300.

This parameter has the configuration ID config_42_2 and is of type INTEGER.

Parameter 43: Hysteresis On

Hysteresis On This parameter defines temperature min difference between real measured temperature and set-point temperature to turn device on. Parameter can be set from 0 to 255 where 0 to 127 means from 0.0 °C to 12.7 °C and from 128 to 255 means from - 0.1 °C to -12.7 °C.

Available configuration parameters

default value 132 (-0.5 °C) Values in the range 0 to 255 may be set.

The manufacturer defined default value is 132.

This parameter has the configuration ID config_43_1 and is of type INTEGER.

Parameter 44: Hysteresis Off

Hysteresis Off This parameter defines temperature min difference between real measured temperature and set-point temperature to turn device off. Parameter can be set from 0 to 255 where 0 to 127 means from 0.0 °C to 12.7 °C and from 128 to 255 means from - 0.1 °C to -12.7 °C.

Available configuration parameters

default value 5 (+0.5 °C) Values in the range 0 to 255 may be set.

The manufacturer defined default value is 5.

This parameter has the configuration ID config_44_1 and is of type INTEGER.

Parameter 45: Antifreeze

Antifreeze function Temperature Set value means at which temperature the device will be turned on even if the thermostat was manually set to off. Parameter can be set from 0 to 255 where 0 to 127 means from 0.0 °C to 12.7 °C and from 128 to 254 means from - 0.1 °C to -12.6 °C.

Available configuration parameters

default value 50 (5,0 °C)

255 – Antifreeze functionality disabled Values in the range 0 to 255 may be set.

The manufacturer defined default value is 5.

This parameter has the configuration ID config_45_1 and is of type INTEGER.

Parameter 60: Too low temperature limit

Too low temperature limit Available configuration parameters

Default value 50 (Too low temperature limit is 5.0°C)

1 - 1000 = 0.1°C – 100.0°C, step is 0.1°C. Too low temperature limit is set by entered value. In case is set value out of this range, module is changing set value automatically to default value. Values in the range 0 to 65535 may be set.

The manufacturer defined default value is 50.

This parameter has the configuration ID config_60_2 and is of type INTEGER.

Parameter 61: Too high temperature limit

Too high temperature limit Available configuration parameters:

Default value 50 (Too low temperature limit is 5.0°C)

1 - 1000 = 0.1°C – 100.0°C, step is 0.1°C. Too low temperature limit is set by entered value. In case is set value out of this range, module is changing set value automatically to default value. Values in the range 0 to 65535 may be set.

The manufacturer defined default value is 700.

This parameter has the configuration ID config_61_2 and is of type INTEGER.

Parameter 63: Switch selection

Connected device type can be (NO) or (NC) Set value means the type of the device that is connected to the relay output. The device type can be normally open (NO) or normally close (NC). Available configuration parameters

default value 0

0 - When system is turned off the output is 0 V.

1 - When system is turned off the output is 230 V. Values in the range 0 to 65535 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_63_2 and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The ZMNHIA supports 6 association groups.

Group 1: Basic on/off Q1

Association group 1 supports 16 nodes.

Group 2: Basic on/off I2

Association group 2 supports 16 nodes.

Group 3: Basic on/off I3

Association group 3 supports 16 nodes.

Group 4: High Temperature

Association group 4 supports 16 nodes.

Group 5: Low Temperature

Association group 5 supports 16 nodes.

Group 6: Default Reporting Group

Association group 6 supports 1 node.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SENSOR_MULTILEVEL_V3
COMMAND_CLASS_METER_V3
COMMAND_CLASS_THERMOSTAT_MODE_V1
COMMAND_CLASS_THERMOSTAT_SETPOINT_V1
COMMAND_CLASS_MULTI_CHANNEL_V2
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_ASSOCIATION_V1
COMMAND_CLASS_VERSION_V1

Endpoint 1

Command Class Comment
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SENSOR_BINARY_V1 Linked to BASIC

Endpoint 2

Command Class Comment
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SENSOR_BINARY_V1 Linked to BASIC