This describes the Z-Wave device ZMNHIA, manufactured by Goap with the thing type UID of qubino_zmnhia_00_000
.
The device is in the category of HVAC, defining Air condition devices, Fans.
The ZMNHIA supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
This Z-Wave module is used to regulate temperature. The module can be controlled either through Z-wave network or through the wall switch
- press service button S for more than 2 second or
- press push button I1 three times within 3s (3 times change switch state within 3 seconds
- press service button S for more than 6 second or
- press push button I1 five times within 3s (5 times change switch state within 3 seconds).
The following table summarises the channels available for the ZMNHIA -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Sensor (temperature) | sensor_temperature | sensor_temperature | Temperature | Number:Temperature |
Electric meter (watts) | meter_watts | meter_watts | Energy | Number |
Electric meter (kWh) | meter_kwh | meter_kwh | Energy | Number |
Thermostat mode | thermostat_mode | thermostat_mode | Temperature | Number |
Setpoint (heating) | thermostat_setpoint | thermostat_setpoint | Heating | Number:Temperature |
Binary Sensor 1 | sensor_binary1 | sensor_binary | Switch | |
Binary Sensor 2 | sensor_binary2 | sensor_binary | Switch |
Indicates the current temperature.
The sensor_temperature
channel is of type sensor_temperature
and supports the Number:Temperature
item and is in the Temperature
category.
Indicates the instantaneous power consumption.
The meter_watts
channel is of type meter_watts
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the energy consumption (kWh).
The meter_kwh
channel is of type meter_kwh
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Sets the thermostat.
The thermostat_mode
channel is of type thermostat_mode
and supports the Number
item and is in the Temperature
category.
The following state translation is provided for this channel to the Number
item type -:
Value | Label |
---|---|
0 | Off |
1 | Heat |
2 | Cool |
3 | Auto |
4 | Aux Heat |
5 | Resume |
6 | Fan Only |
7 | Furnace |
8 | Dry Air |
9 | Moist Air |
10 | Auto Changeover |
11 | Heat Economy |
12 | Cool Economy |
13 | Away |
Sets the thermostat setpoint.
The thermostat_setpoint
channel is of type thermostat_setpoint
and supports the Number:Temperature
item and is in the Heating
category.
Indicates if a sensor has triggered.
The sensor_binary1
channel is of type sensor_binary
and supports the Switch
item. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
ON | Triggered |
OFF | Untriggered |
Indicates if a sensor has triggered.
The sensor_binary2
channel is of type sensor_binary
and supports the Switch
item. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
ON | Triggered |
OFF | Untriggered |
The following table provides a summary of the 17 configuration parameters available in the ZMNHIA. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Input 1 switch type | Input 1 switch type |
2 | Input 2 switch type | Input 2 switch type |
3 | Input 3 switch type | Input 3 switch type |
4 | Input 2 contact type | |
5 | Input 3 contact type | |
10 | Activate / deactivate functions ALL ON/ALL OFF | Module responds to commands ALL ON / ALL OFF |
11 | Set point set by I2 | Set point set by I2 |
12 | Set point set by I3 | Set point set by I3 |
30 | Saving the state after a power failure | Saving the state after a power failure |
40 | Power reporting in Watts on power change for Q1 | Power reporting in Watts on power change |
42 | Power reporting in Watts by time interval for Q1 | Power reporting in Watts by time interval |
43 | Hysteresis On | Hysteresis On |
44 | Hysteresis Off | Hysteresis Off |
45 | Antifreeze | Antifreeze function Temperature |
60 | Too low temperature limit | Too low temperature limit |
61 | Too high temperature limit | Too high temperature limit |
63 | Switch selection | Connected device type can be (NO) or (NC) |
Input 1 switch type
The following option values may be configured -:
Value | Description |
---|---|
0 | mono-stable switch type (push button) |
1 | bi-stable switch type |
The manufacturer defined default value is 1
(bi-stable switch type).
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
Input 2 switch type
The following option values may be configured -:
Value | Description |
---|---|
0 | mono-stable switch type (push button) |
1 | bi-stable switch type |
The manufacturer defined default value is 1
(bi-stable switch type).
This parameter has the configuration ID config_2_1
and is of type INTEGER
.
Input 3 switch type
The following option values may be configured -:
Value | Description |
---|---|
0 | mono-stable switch type (push button) |
1 | bi-stable switch type |
The manufacturer defined default value is 1
(bi-stable switch type).
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
The following option values may be configured -:
Value | Description |
---|---|
0 | NO (normally open) input type |
1 | NC (normally close) input type |
The manufacturer defined default value is 0
(NO (normally open) input type).
This parameter has the configuration ID config_4_1
and is of type INTEGER
.
The following option values may be configured -:
Value | Description |
---|---|
0 | NO (normally open) input type |
1 | NC (normally close) input type |
The manufacturer defined default value is 0
(NO (normally open) input type).
This parameter has the configuration ID config_5_1
and is of type INTEGER
.
Module responds to commands ALL ON / ALL OFF Module responds to commands ALL ON / ALL OFF that may be sent by the main controller or by other controller belonging to the system. The following option values may be configured -:
Value | Description |
---|---|
0 | ALL ON is not active ALL OFF is not active |
1 | ALL ON is not active ALL OFF active |
2 | ALL ON active ALL OFF is not active |
255 | ALL ON active, ALL OFF active |
The manufacturer defined default value is 255
(ALL ON active, ALL OFF active).
This parameter has the configuration ID config_10_1
and is of type INTEGER
.
Set point set by I2 When I2 is pressed set point will be set according to the value of this parameter. Available config. parameters:
default value 65535
65535 – input I2 does not influence on the set point
From 0 to 990 – set point from 0.0 °C to 99.0 °C
From 1001 to 1150 – set point from -0.1 °C to -15.0 °C Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_11_2
and is of type INTEGER
.
Set point set by I3 When I3 is pressed set point will be set according to the value of this parameter. Available config. parameters
default value 65535
65535 – input I3 does not influence on the set point
From 0 to 990 – set point from 0.0 °C to 99.0 °C
From 1001 to 1150 – set point from -0.1 °C to -15.0 °C Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_12_2
and is of type INTEGER
.
Saving the state after a power failure
The following option values may be configured -:
Value | Description |
---|---|
0 | Module saves its state |
1 | Module does not save state |
The manufacturer defined default value is 0
(Module saves its state).
This parameter has the configuration ID config_30_1
and is of type INTEGER
.
Power reporting in Watts on power change Set value means percentage, set value from 0 - 100=0% - 100%. Available configuration parameters
default value 3
0 – Reporting Disabled
1–100 = 1%-100% Reporting enabled. Power report is sent (push) only when actual power in Watts in real time changes for more than set percentage comparing to previous actual power in Watts, step is 1%.
NOTE: If power changed is less than 1W, the report is not sent (pushed), independent of percentage set. Values in the range 0 to 255 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_40_1
and is of type INTEGER
.
Power reporting in Watts by time interval Set value means time interval (0 – 65535) in seconds, when power report is send. Available config. parameters
default value 300 (power report in Watts is send each 300s)
0 – Reporting Disabled
1 – 65535 = 1second – 65535 seconds. Reporting enabled. Power report is send with time interval set by entered value. Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 300
.
This parameter has the configuration ID config_42_2
and is of type INTEGER
.
Hysteresis On This parameter defines temperature min difference between real measured temperature and set-point temperature to turn device on. Parameter can be set from 0 to 255 where 0 to 127 means from 0.0 °C to 12.7 °C and from 128 to 255 means from - 0.1 °C to -12.7 °C.
Available configuration parameters
default value 132 (-0.5 °C) Values in the range 0 to 255 may be set.
The manufacturer defined default value is 132
.
This parameter has the configuration ID config_43_1
and is of type INTEGER
.
Hysteresis Off This parameter defines temperature min difference between real measured temperature and set-point temperature to turn device off. Parameter can be set from 0 to 255 where 0 to 127 means from 0.0 °C to 12.7 °C and from 128 to 255 means from - 0.1 °C to -12.7 °C.
Available configuration parameters
default value 5 (+0.5 °C) Values in the range 0 to 255 may be set.
The manufacturer defined default value is 5
.
This parameter has the configuration ID config_44_1
and is of type INTEGER
.
Antifreeze function Temperature Set value means at which temperature the device will be turned on even if the thermostat was manually set to off. Parameter can be set from 0 to 255 where 0 to 127 means from 0.0 °C to 12.7 °C and from 128 to 254 means from - 0.1 °C to -12.6 °C.
Available configuration parameters
default value 50 (5,0 °C)
255 – Antifreeze functionality disabled Values in the range 0 to 255 may be set.
The manufacturer defined default value is 5
.
This parameter has the configuration ID config_45_1
and is of type INTEGER
.
Too low temperature limit Available configuration parameters
Default value 50 (Too low temperature limit is 5.0°C)
1 - 1000 = 0.1°C – 100.0°C, step is 0.1°C. Too low temperature limit is set by entered value. In case is set value out of this range, module is changing set value automatically to default value. Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 50
.
This parameter has the configuration ID config_60_2
and is of type INTEGER
.
Too high temperature limit Available configuration parameters:
Default value 50 (Too low temperature limit is 5.0°C)
1 - 1000 = 0.1°C – 100.0°C, step is 0.1°C. Too low temperature limit is set by entered value. In case is set value out of this range, module is changing set value automatically to default value. Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 700
.
This parameter has the configuration ID config_61_2
and is of type INTEGER
.
Connected device type can be (NO) or (NC) Set value means the type of the device that is connected to the relay output. The device type can be normally open (NO) or normally close (NC). Available configuration parameters
default value 0
0 - When system is turned off the output is 0 V.
1 - When system is turned off the output is 230 V. Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_63_2
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The ZMNHIA supports 6 association groups.
Association group 1 supports 16 nodes.
Association group 2 supports 16 nodes.
Association group 3 supports 16 nodes.
Association group 4 supports 16 nodes.
Association group 5 supports 16 nodes.
Association group 6 supports 1 node.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SENSOR_MULTILEVEL_V3 | |
COMMAND_CLASS_METER_V3 | |
COMMAND_CLASS_THERMOSTAT_MODE_V1 | |
COMMAND_CLASS_THERMOSTAT_SETPOINT_V1 | |
COMMAND_CLASS_MULTI_CHANNEL_V2 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_ASSOCIATION_V1 | |
COMMAND_CLASS_VERSION_V1 |
Command Class | Comment |
---|---|
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SENSOR_BINARY_V1 | Linked to BASIC |
Command Class | Comment |
---|---|
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SENSOR_BINARY_V1 | Linked to BASIC |