ZMNHDD Flush Dimmer Plus

This describes the Z-Wave device ZMNHDD, manufactured by Goap with the thing type UID of qubino_zmnhdd_00_000.

The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.

ZMNHDD product image

The ZMNHDD supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

This Z-Wave module is used for dimming the bulb or to manage the speed of a fan. The module can be controlled either through a Z-Wave network or through the wall switch. The module is designed to be mounted inside a "flush mounting box", hidden behind a traditional wall switch. Module measures power consumption of bulb or fan and supports connection of digital temperature sensor. It is designed to act as repeater in order to improve range and stability of Z-wave network.

Inclusion Information

WARNING: Service button S must NOT be used when module is connected to 110-230V power supply.

  • Connect module to power supply (with temperature sensor connected - if purchased),
  • Enable add/remove mode on main controller
  • Auto-inclusion (works for about 2 minutesafter connected to power supply) or
  • **110V-230V power supply: **Press push button I1 three times within 3 seconds (3 times change switch state within 3 seconds)
  • **24V SELV: **Press service button S for more than 2 seconds.

NOTE1: For auto-inclusion procedure, first set main controller into inclusion mode and then connect module to power supply.

NOTE2: When connecting temperature sensor to module that has already been included, you have to exclude module first. Switch off power supply,connect the sensor and re-include the module.

Exclusion Information

WARNING: Service button S must NOT be used when module is connected to 110-230V power supply.

  • Connect module to power supply
  • Bring module within maximum 1 meter (3 feet) of the main controller
  • Enable add/remove mode on main controller
  • 110V-230V power supply: Press push button I1 five times within 3 seconds (5 times change switch state within 3 seconds) in the first 60 seconds after the module is connected to the power supply
  • 24V SELV: Press ervice button S for more than 6 seconds.

By this function all parameters of the module are set to default values and own ID is deleted. If push button I1 is pressed three times within 3 seconds (or service button S is pressed more than 2 and less than 6 seconds) module is excluded, but configuration parameters are not set to default values.

NOTE: If the module is included with parameters 100 or 101 with values different to default and module reset is done, wait at least 30s before next inclusion.

Channels

The following table summarises the channels available for the ZMNHDD -:

Channel Name Channel ID Channel Type Category Item Type
Switch [Deprecated] switch_binary switch_binary Switch Switch
Dimmer switch_dimmer switch_dimmer DimmableLight Dimmer
Binary Sensor sensor_binary sensor_binary Switch
Sensor (temperature) sensor_temperature sensor_temperature Temperature Number:Temperature
Electric meter (kWh) meter_kwh meter_kwh Energy Number
Electric meter (watts) meter_watts meter_watts Energy Number
Reset the total power consumption meter_reset meter_reset Energy Switch
Alarm alarm_general alarm_general Alarm Switch
Switch 1 [Deprecated] switch_binary1 switch_binary Switch Switch
Dimmer 1 switch_dimmer1 switch_dimmer DimmableLight Dimmer
Electric meter (kWh) 1 meter_kwh1 meter_kwh Energy Number
Electric meter (watts) 1 meter_watts1 meter_watts Energy Number
Binary Sensor 2 sensor_binary2 sensor_binary Switch
Sensor (temperature) 2 sensor_temperature2 sensor_temperature Temperature Number:Temperature
Alarm 2 alarm_general2 alarm_general Alarm Switch
Binary Sensor 3 sensor_binary3 sensor_binary Switch
Alarm 3 alarm_general3 alarm_general Alarm Switch

Switch [Deprecated]

Switch the power on and off.

The switch_binary channel is of type switch_binary and supports the Switch item and is in the Switch category.

Note: This channel is marked as deprecated so should not be used.

Dimmer

The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.

The switch_dimmer channel is of type switch_dimmer and supports the Dimmer item and is in the DimmableLight category.

Binary Sensor

Indicates if a sensor has triggered.

The sensor_binary channel is of type sensor_binary and supports the Switch item. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
ON Triggered
OFF Untriggered

Sensor (temperature)

Indicates the current temperature.

The sensor_temperature channel is of type sensor_temperature and supports the Number:Temperature item and is in the Temperature category.

Electric meter (kWh)

Indicates the energy consumption (kWh).

The meter_kwh channel is of type meter_kwh and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (watts)

Indicates the instantaneous power consumption.

The meter_watts channel is of type meter_watts and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Reset the total power consumption

Reset the meter.

The meter_reset channel is of type meter_reset and supports the Switch item and is in the Energy category.

Alarm

Indicates if an alarm is triggered.

The alarm_general channel is of type alarm_general and supports the Switch item and is in the Alarm category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Switch 1 [Deprecated]

Switch the power on and off.

The switch_binary1 channel is of type switch_binary and supports the Switch item and is in the Switch category.

Note: This channel is marked as deprecated so should not be used.

Dimmer 1

The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.

The switch_dimmer1 channel is of type switch_dimmer and supports the Dimmer item and is in the DimmableLight category.

Electric meter (kWh) 1

Indicates the energy consumption (kWh).

The meter_kwh1 channel is of type meter_kwh and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (watts) 1

Indicates the instantaneous power consumption.

The meter_watts1 channel is of type meter_watts and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Binary Sensor 2

Indicates if a sensor has triggered.

The sensor_binary2 channel is of type sensor_binary and supports the Switch item. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
ON Triggered
OFF Untriggered

Sensor (temperature) 2

Indicates the current temperature.

The sensor_temperature2 channel is of type sensor_temperature and supports the Number:Temperature item and is in the Temperature category.

Alarm 2

Indicates if an alarm is triggered.

The alarm_general2 channel is of type alarm_general and supports the Switch item and is in the Alarm category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Binary Sensor 3

Indicates if a sensor has triggered.

The sensor_binary3 channel is of type sensor_binary and supports the Switch item. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
ON Triggered
OFF Untriggered

Alarm 3

Indicates if an alarm is triggered.

The alarm_general3 channel is of type alarm_general and supports the Switch item and is in the Alarm category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Device Configuration

The following table provides a summary of the 23 configuration parameters available in the ZMNHDD. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Input 1 switch type
2 Input 2 switch type
3 Input 2 contact type
4 Input 3 contact type
10 Activate / deactivate functions ALL ON / ALL OFF Flush dimmer module responds to commands ALL ON / ALL OFF
11 Automatic turning off output after set time Auto OFF enabled with defined time, step is 1 second.
12 Automatic turning on output after set time Auto ON enabled with defined time, step is 1 second.
20 Enable / Disable 3-way switch Dimming is done by push button or switch connected to I1.
21 Enable / Disable Double click function A fast double click on the push button will set dimming power at maximum.
30 Saving the state after a power failure Saving the state after a power failure
40 Power reporting in watts on power change Set value is percentage, set value from 0 - 100 = 0% - 100%.
42 Power reporting in Watts by time interval Set value means time interval (0 – 32767) in seconds.
60 Minimum dimming value Minimum dimming value is set by entered value.
61 Maximum dimming value Maximum dimming value is set by entered value.
65 Dimming time (soft on/off) Set value means time of moving the Dimmer between min. and max. dimming values
66 Dimming time when key pressed Time of moving the Dimmer between min. and max dimming values
67 Ignore start level This parameter is used with association group 3
68 Dimming duration This parameter is used with association group 3
100 Enable / Disable Endpoints I2 Enabling I2 means that Endpoint (I2) will be present on UI.
101 Enable / Disable Endpoints I3 Enabling I3 means that Endpoint (I3) will be present on UI.
110 Temperature sensor offset settings Offset to actual measured value
120 Digital temperature sensor reporting Module reports measured temperature on defined temperature change
250 Unsecure / Secure Inclusion Unsecure / Secure Inclusion

Parameter 1: Input 1 switch type

The following option values may be configured -:

Value Description
0 Mono-stable switch type (push button)
1 Bi-stable switch type

The manufacturer defined default value is 0 (Mono-stable switch type (push button)).

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Parameter 2: Input 2 switch type

The following option values may be configured -:

Value Description
0 Mono-stable switch type (push button)
1 Bi-stable switch type

The manufacturer defined default value is 0 (Mono-stable switch type (push button)).

This parameter has the configuration ID config_2_1 and is of type INTEGER.

Parameter 3: Input 2 contact type

The following option values may be configured -:

Value Description
0 NO (normally open) input type
1 NC (normally closed) input type

The manufacturer defined default value is 0 (NO (normally open) input type).

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Parameter 4: Input 3 contact type

The following option values may be configured -:

Value Description
0 NO (normally open) input type
1 NC (normally closed) input type

The manufacturer defined default value is 0 (NO (normally open) input type).

This parameter has the configuration ID config_4_1 and is of type INTEGER.

Parameter 10: Activate / deactivate functions ALL ON / ALL OFF

Flush dimmer module responds to commands ALL ON / ALL OFF Flush dimmer module responds to commands ALL ON / ALL OFF that may be sent by the main controller or by other controller belonging to the system. The following option values may be configured -:

Value Description
0 ALL ON is not active, ALL OFF is not active
1 ALL ON is not active, ALL OFF active
2 ALL ON active, ALL OFF is not active
255 ALL ON active, ALL OFF active

The manufacturer defined default value is 255 (ALL ON active, ALL OFF active).

This parameter has the configuration ID config_10_2 and is of type INTEGER.

Parameter 11: Automatic turning off output after set time

Auto OFF enabled with defined time, step is 1 second.

  • 0 - Auto OFF disabled
  • 1 – 32536 = 1 second – 32536 seconds Values in the range 0 to 32536 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_11_2 and is of type INTEGER.

Parameter 12: Automatic turning on output after set time

Auto ON enabled with defined time, step is 1 second.

  • 0 - Auto ON disabled
  • 1 – 32536 = 1 second – 32536 seconds Values in the range 0 to 32536 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_12_2 and is of type INTEGER.

Parameter 20: Enable / Disable 3-way switch

Dimming is done by push button or switch connected to I1. Dimming is done by push button or switch connected to I1 (by default).

Enabling 3way switch, dimming can be controlled by push button or switch connected to I1 and I2. The following option values may be configured -:

Value Description
0 single push button (connected to I1)
1 3-way switch (connected to I1 and I2)
2 Additional switch connected to I2

The manufacturer defined default value is 0 (single push button (connected to I1)).

This parameter has the configuration ID config_20_1 and is of type INTEGER.

Parameter 21: Enable / Disable Double click function

A fast double click on the push button will set dimming power at maximum. If Double click function is enabled, a fast double click on the push button will set dimming power at maximum dimming value. The following option values may be configured -:

Value Description
0 double click disabled
1 double click enabled

The manufacturer defined default value is 0 (double click disabled).

This parameter has the configuration ID config_21_1 and is of type INTEGER.

Parameter 30: Saving the state after a power failure

Saving the state after a power failure If state saving is enabled, flush dimmer module saves its state before power failure (it returns to the last position saved before a power failure).

If state saving is disabled, flush dimmer module does not save the state after a power failure. The following option values may be configured -:

Value Description
0 Save state enabled
1 Save state disabled

The manufacturer defined default value is 0 (Save state enabled).

This parameter has the configuration ID config_30_1 and is of type INTEGER.

Parameter 40: Power reporting in watts on power change

Set value is percentage, set value from 0 - 100 = 0% - 100%. Set value means percentage, set value from 0 - 100 = 0% - 100%. Default value is 5.

  • 0 – Reporting Disabled
  • 1 – 100 = 1% - 100% Reporting enabled.

Power report is send (push) only when actual power in Watts in real time changes for more than set percentage comparing to previous actual power in Watts, step is 1%.

NOTE: if power changed is less than 1W, the report is not send (pushed), independent of percentage set. Values in the range 0 to 100 may be set.

The manufacturer defined default value is 5.

This parameter has the configuration ID config_40_1 and is of type INTEGER.

Parameter 42: Power reporting in Watts by time interval

Set value means time interval (0 – 32767) in seconds. Set value means time interval (0 – 32767) in seconds, when power report is sent.

  • 0 – reporting disabled
  • 1 – 32767 = 1 second – 32767 seconds. Reporting enabled.

Power report is send with time interval set by entered value. Values in the range 0 to 32767 may be set.

The manufacturer defined default value is 300.

This parameter has the configuration ID config_42_2 and is of type INTEGER.

Parameter 60: Minimum dimming value

Minimum dimming value is set by entered value.

  • 1-98 = 1% – 98%, step is 1%. Minimum dimming value is set by entered value.

NOTE: The minimum level may not be higher than the maximum level! 1% min. dimming value is defined by Z- Wave multilevel device class. Values in the range 1 to 98 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_60_1 and is of type INTEGER.

Parameter 61: Maximum dimming value

Maximum dimming value is set by entered value.

  • 2-99 = 2% – 99%, step is 1%. Maximum dimming value is set by entered value.

NOTE: The maximum level may not be lower than the minimum level! 99% max. dimming value is defined by Z- Wave multilevel device class. Values in the range 2 to 99 may be set.

The manufacturer defined default value is 99.

This parameter has the configuration ID config_61_1 and is of type INTEGER.

Parameter 65: Dimming time (soft on/off)

Set value means time of moving the Dimmer between min. and max. dimming values Set value means time of moving the Dimmer between min. and max. dimming values by short press of push button I1 or controlled through UI (BasicSet).

  • default value 100 = 1s
  • 1 - 255 = 100 mseconds – 25500 mseconds, step is 10 mseconds Values in the range 1 to 255 may be set.

The manufacturer defined default value is 100.

This parameter has the configuration ID config_65_2 and is of type INTEGER.

Parameter 66: Dimming time when key pressed

Time of moving the Dimmer between min. and max dimming values Time of moving the Dimmer between min. and max dimming values by continuous hold of push button I1 or associated device.

  • default value 3 = 3s
  • 1- 255 = 1 second – 255 seconds. Values in the range 1 to 255 may be set.

The manufacturer defined default value is 3.

This parameter has the configuration ID config_66_2 and is of type INTEGER.

Parameter 67: Ignore start level

This parameter is used with association group 3 This parameter is used with association group 3. A receiving device SHOULD respect the start level if the Ignore Start Level bit is 0. A receiving device MUST ignore the start level if the Ignore Start Level bit is 1. The following option values may be configured -:

Value Description
0 respect start level
1 ignore start level

The manufacturer defined default value is 0 (respect start level).

This parameter has the configuration ID config_67_1 and is of type INTEGER.

Parameter 68: Dimming duration

This parameter is used with association group 3 This parameter is used with association group 3. The Duration field MUST specify the time that the transition should take from the current value to the new target value. A supporting device SHOULD respect the specified Duration value. Values in the range 0 to 127 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_68_1 and is of type INTEGER.

Parameter 100: Enable / Disable Endpoints I2

Enabling I2 means that Endpoint (I2) will be present on UI. Enabling I2 means that Endpoint (I2) will be present on UI. Disabling it will result in hiding the endpoint according to the parameter set value. Additionally, a Notification Type and Event can be selected for the endpoint.

NOTE1: After parameter change, first exclude module (without setting parameters to default value) then wait at least 30s and then re include the module!

NOTE 2: When the parameter is set to value 9 the notifications are send for Home Security. The following option values may be configured -:

Value Description
0 Disabled
1 Home Security
2 Carbon Monoxide
3 Carbon Dioxide
4 Water Alarm
5 Heat Alarm
6 Smoke Alarm
9 Sensor binary

The manufacturer defined default value is 0 (Disabled).

This parameter has the configuration ID config_100_1 and is of type INTEGER.

Parameter 101: Enable / Disable Endpoints I3

Enabling I3 means that Endpoint (I3) will be present on UI. Enabling I3 means that Endpoint (I3) will be present on UI. Disabling it will result in hiding the endpoint according to the parameter set value. Additionally, a Notification Type and Event can be selected for the endpoint.

NOTE1: After parameter change, first exclude module (without setting parameters to default value) then wait at least 30s and then re include the module!

NOTE 2: When the parameter is set to value 9 the notifications are send for Home Security. The following option values may be configured -:

Value Description
0 Disabled
1 Home Security
2 Carbon Monoxide
3 Carbon Dioxide
4 Water Alarm
5 Heat Alarm
6 Smoke Alarm
9 Sensor binary

The manufacturer defined default value is 0 (Disabled).

This parameter has the configuration ID config_101_1 and is of type INTEGER.

Parameter 110: Temperature sensor offset settings

Offset to actual measured value Set value is added or subtracted to actual measured value by sensor. Available configuration parameters:

  • default value 32536
  • 32536 – offset is 0.0C
  • From 1 to 100 – value from 0.1 °C to 10.0 °C is added to actual measured temperature.
  • From 1001 to 1100 -value from -0.1 °C to -10.0 °C is subtracted to actual measured temperature. Values in the range 1 to 32536 may be set.

The manufacturer defined default value is 32536.

This parameter has the configuration ID config_110_2 and is of type INTEGER.

Parameter 120: Digital temperature sensor reporting

Module reports measured temperature on defined temperature change If digital temperature sensor is connected, module reports measured temperature on temperature change defined by this parameter. Available configuration parameters:

  • default value 5 = 0.5°C
  • 0 – Reporting disabled Values in the range 0 to 127 may be set.

The manufacturer defined default value is 5.

This parameter has the configuration ID config_120_1 and is of type INTEGER.

Parameter 250: Unsecure / Secure Inclusion

Unsecure / Secure Inclusion The Flush dimmer supports both, the secure and unsecure inclusion. Even if the controller does not support security command classes, a dimmer could be included as unsecure and keep all the functionalityThis is an advanced parameter and will therefore not show in the user interface without entering advanced mode. The following option values may be configured -:

Value Description
0 Unsecure Inclusion
1 Secure Inclusion

The manufacturer defined default value is 0 (Unsecure Inclusion).

This parameter has the configuration ID config_250_1 and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The ZMNHDD supports 11 association groups.

Group 1: Controller Updates

Lifeline group

Association group 1 supports 1 node.

Group 2: I1 basic on/off

Triggered at change of the input I1 state and reflecting its state

Association group 2 supports 16 nodes.

Group 3: I1 start/stop level change

Triggered at change of the input I1 state and reflecting its state

Association group 3 supports 16 nodes.

Group 4: Multilevel

Triggered at changes of state/value of the Flush Dimmer

Association group 4 supports 16 nodes.

Group 5: I2 basic on/off

Triggered at change of the input I2 state and reflecting its state

Association group 5 supports 16 nodes.

Group 6: I2 notification report

Triggered at change of the input I2 state and reflecting its state

Association group 6 supports 16 nodes.

Group 7: I2 binary sensor

Triggered at change of the input I2 state and reflecting its state

Association group 7 supports 16 nodes.

Group 8: I3 basic on/off

Triggered at change of the input I3 state and reflecting its state

Association group 8 supports 16 nodes.

Group 9: I3 notification report

Triggered at change of the input I3 state and reflecting its state

Association group 9 supports 16 nodes.

Group 10: I3 binary sensor

Triggered at change of the input I3 state and reflecting its state

Association group 10 supports 16 nodes.

Group 11: Multilevel sensor

Triggered at change of temperature sensor

Association group 11 supports 16 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1
COMMAND_CLASS_SWITCH_MULTILEVEL_V1 Linked to BASIC
COMMAND_CLASS_SENSOR_BINARY_V1
COMMAND_CLASS_SENSOR_MULTILEVEL_V5
COMMAND_CLASS_METER_V3
COMMAND_CLASS_MULTI_CHANNEL_V2
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_ALARM_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_ASSOCIATION_V1
COMMAND_CLASS_VERSION_V1

Endpoint 1

Command Class Comment
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1
COMMAND_CLASS_SWITCH_MULTILEVEL_V3 Linked to BASIC
COMMAND_CLASS_METER_V3
COMMAND_CLASS_ASSOCIATION_V1
COMMAND_CLASS_VERSION_V1

Endpoint 2

Command Class Comment
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SENSOR_BINARY_V1 Linked to BASIC
COMMAND_CLASS_SENSOR_MULTILEVEL_V7
COMMAND_CLASS_ALARM_V1
COMMAND_CLASS_ASSOCIATION_V1
COMMAND_CLASS_VERSION_V1

Endpoint 3

Command Class Comment
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SENSOR_BINARY_V1 Linked to BASIC
COMMAND_CLASS_ALARM_V1
COMMAND_CLASS_ASSOCIATION_V1
COMMAND_CLASS_VERSION_V1

Documentation Links