This describes the Z-Wave device PSE02, manufactured by Philio Technology Corp with the thing type UID of philio_pse02_00_000
.
The device is in the category of Siren, defining Siren used by Alarm systems.
The PSE02 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
The PSE02 is a wireless siren with multiple sound capabilities.
Put controller into inclusion mode. Press tamper key three times within 1.5 seconds. After device was added successfully, the LED will turn on for 1 second.
Put controller into exclusion mode. Press tamper key three times within 1.5 seconds.
The following table summarises the channels available for the PSE02 -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Switch | switch_binary | switch_binary | Switch | Switch |
Start sound | notification_send | notification_send | Number |
Switch the power on and off.
The switch_binary
channel is of type switch_binary
and supports the Switch
item and is in the Switch
category.
Sends a notification.
The notification_send
channel is of type notification_send
and supports the Number
item.
The following table provides a summary of the 3 configuration parameters available in the PSE02. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
7 | Costumer Function | NotificationReport/BinaryReport |
29 | Disable Alarm | Disable the alarm function. |
31 | Alarm Duration |
NotificationReport/BinaryReport Customer function switch, using bit control. 0 Bit4: Notification Type, 0: Using Notification Report. 1: Using Sensor Binary Report.This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 65535 may be set.
The manufacturer defined default value is 4
.
This parameter has the configuration ID config_7_4
and is of type INTEGER
.
Disable the alarm function. Disable the alarm function. 1: Disable Alarm, 0: Enable Alarm. Caution: After the power up, this configuration is always 0. Values in the range 0 to 0 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_29_4
and is of type INTEGER
.
Values in the range 0 to 127 may be set.
The manufacturer defined default value is 6
.
This parameter has the configuration ID config_31_4_0000000C
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The device does not support associations.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_ALARM_V3 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1 | |
COMMAND_CLASS_VERSION_V1 | |
COMMAND_CLASS_SECURITY_V1 |