This describes the Z-Wave device PSE02, manufactured by Philio Technology Corp with the thing type UID of philio_pse02_00_000.

The device is in the category of Siren, defining Siren used by Alarm systems.

PSE02 product image

The PSE02 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

The PSE02 is a wireless siren with multiple sound capabilities.

Inclusion Information

Put controller into inclusion mode. Press tamper key three times within 1.5 seconds. After device was added successfully, the LED will turn on for 1 second.

Exclusion Information

Put controller into exclusion mode. Press tamper key three times within 1.5 seconds.

Channels

The following table summarises the channels available for the PSE02 -:

Channel Name Channel ID Channel Type Category Item Type
Switch switch_binary switch_binary Switch Switch
Start sound notification_send notification_send Number

Switch

Switch the power on and off.

The switch_binary channel is of type switch_binary and supports the Switch item and is in the Switch category.

Start sound

Sends a notification.

The notification_send channel is of type notification_send and supports the Number item.

Device Configuration

The following table provides a summary of the 3 configuration parameters available in the PSE02. Detailed information on each parameter can be found in the sections below.

Param Name Description
7 Costumer Function NotificationReport/BinaryReport
29 Disable Alarm Disable the alarm function.
31 Alarm Duration

Parameter 7: Costumer Function

NotificationReport/BinaryReport Customer function switch, using bit control. 0       Bit4: Notification Type,       0: Using Notification Report.   1: Using Sensor Binary Report.This is an advanced parameter and will therefore not show in the user interface without entering advanced mode. Values in the range 0 to 65535 may be set.

The manufacturer defined default value is 4.

This parameter has the configuration ID config_7_4 and is of type INTEGER.

Parameter 29: Disable Alarm

Disable the alarm function. Disable the alarm  function. 1: Disable  Alarm, 0: Enable Alarm.  Caution: After the power  up, this configuration is  always 0. Values in the range 0 to 0 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_29_4 and is of type INTEGER.

Parameter 31: Alarm Duration

Values in the range 0 to 127 may be set.

The manufacturer defined default value is 6.

This parameter has the configuration ID config_31_4_0000000C and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The device does not support associations.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_ALARM_V3
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1
COMMAND_CLASS_VERSION_V1
COMMAND_CLASS_SECURITY_V1

Documentation Links