PAT02-B Z-Wave room sensor

This describes the Z-Wave device PAT02-B, manufactured by Philio Technology Corp with the thing type UID of philio_pat02b_00_000.

The device is in the category of Sensor, defining Device used to measure something.

PAT02-B product image

The PAT02-B supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.

The PAT02-B does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. Refer to the Wakeup Information section below for further information.

Overview

The flood multisensor PAT02 has flood, temperature and humidity, 3 sensors function in one, based on Z-WaveTM technology

Inclusion Information

Pressing the tamper key three times within 1.5 seconds to enter the inclusion mode.

Exclusion Information

Pressing tamper key three times within 1.5 seconds to enter the exclusion mode

Wakeup Information

The PAT02-B does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour.

The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.

Press the tamper key once. The device will wake-up 10 seconds.

Channels

The following table summarises the channels available for the PAT02-B -:

Channel Name Channel ID Channel Type Category Item Type
Binary Sensor sensor_binary sensor_binary Switch
Sensor (temperature) sensor_temperature sensor_temperature Temperature Number:Temperature
Sensor (relative humidity) sensor_relhumidity sensor_relhumidity Humidity Number
Alarm (burglar) alarm_burglar alarm_burglar Door Switch
Battery Level battery-level system.battery_level Battery Number

Binary Sensor

Indicates if a sensor has triggered.

The sensor_binary channel is of type sensor_binary and supports the Switch item. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
ON Triggered
OFF Untriggered

Sensor (temperature)

Indicates the current temperature.

The sensor_temperature channel is of type sensor_temperature and supports the Number:Temperature item and is in the Temperature category.

Sensor (relative humidity)

Indicates the current relative humidity.

The sensor_relhumidity channel is of type sensor_relhumidity and supports the Number item and is in the Humidity category. This is a read only channel so will only be updated following state changes from the device.

Alarm (burglar)

Indicates if the burglar alarm is triggered.

The alarm_burglar channel is of type alarm_burglar and supports the Switch item and is in the Door category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Battery Level

Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.

The system.battery-level channel is of type system.battery-level and supports the Number item and is in the Battery category. This channel provides the battery level as a percentage and also reflects the low battery warning state. If the battery state is in low battery warning state, this will read 0%.

Device Configuration

The following table provides a summary of the 8 configuration parameters available in the PAT02-B. Detailed information on each parameter can be found in the sections below.

Param Name Description
5 Operation Mode set Operation Mode using bit to control
7 Customer Function Customer Function switch using bit control
10 Auto Report Battery Time The interval time for auto reporting the battery level.
13 Auto Report Temperature Time The interval time for auto reporting the temperature state.
14 Auto Report Humidity Time The interval time for auto reporting the humidity state.
20 Auto Report Tick Interval The interval time for auto report each tick.
21 Temperature Differential Report The temperature differential to report.
23 Humidity Differential Report The humidity differential to report.
Wakeup Interval Sets the interval at which the device will accept commands from the controller
Wakeup Node Sets the node ID of the device to receive the wakeup notifications

Parameter 5: Operation Mode

set Operation Mode using bit to control set Operation Mode using bit to control

  • Bit 0: Reserve
  • Bit 1: Reserve
  • Bit 2: Reserve
  • Bit 3: Setting temperature scale
    • 0: Fahrenheit
    • 1: Celsius
  • Bit 4: Reserve
  • Bit 5: Reserve
  • Bit 6: Reserve
  • Bit 7: Reserve Values in the range 0 to 255 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_5_1 and is of type INTEGER.

Parameter 7: Customer Function

Customer Function switch using bit control Customer Function switch using bit control

  • Bit 0: Reserve
  • Bit 1: Reserve
  • Bit 2: Reserve
  • Bit 3: not applicable for this device variant, set to 0
  • Bit 4: Notification Type
    • 0: Using Notification Report
    • 1: Using Sensor Binary Report
  • Bit 5: Disable Multi CC in auto report
    • 0: Enable
    • 1: Disable
  • Bit 6: not applicable for this device variant, set to 0
  • Bit 7: Reserve Values in the range 0 to 255 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_7_1 and is of type INTEGER.

Parameter 10: Auto Report Battery Time

The interval time for auto reporting the battery level. The interval time for auto reporting the battery level.

  • 0 = Turn off auto report battery.
  • 1-127 = Number of ticks. The default value is 12. The tick time can be set by configuration No. 20. Values in the range 1 to 127 may be set.

The manufacturer defined default value is 12.

This parameter has the configuration ID config_10_1 and is of type INTEGER.

Parameter 13: Auto Report Temperature Time

The interval time for auto reporting the temperature state. The interval time for auto reporting the temperature state.

  • 0 = Turn off auto report temperature.
  • 1-127 = Number of ticks. The default value is 12. The tick time can be set by configuration No. 20. Values in the range 1 to 127 may be set.

The manufacturer defined default value is 12.

This parameter has the configuration ID config_13_1 and is of type INTEGER.

Parameter 14: Auto Report Humidity Time

The interval time for auto reporting the humidity state. The interval time for auto reporting the humidity state.

  • 0 = Turn off auto report.
  • 1-127 = Number of ticks. The default value is 12. The tick time can be set by configuration No. 20. Values in the range 0 to 127 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_14_1 and is of type INTEGER.

Parameter 20: Auto Report Tick Interval

The interval time for auto report each tick. The interval time for auto report each tick. Units of one minute. Setting configuration will affect configuration no. 10, 13, 14 and 15.

  • Caution1: Setting to 0 means turn off all auto report function.
  • Caution2: The value is unsigned byte. Values in the range 0 to 255 may be set.

The manufacturer defined default value is 30.

This parameter has the configuration ID config_20_1 and is of type INTEGER.

Parameter 21: Temperature Differential Report

The temperature differential to report. The temperature differential to report.

  • The unit is Fahrenheit.
  • Enable this function the device will detect every 10 seconds. Values in the range 0 to 127 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_21_1 and is of type INTEGER.

Parameter 23: Humidity Differential Report

The humidity differential to report. The humidity differential to report.

  • The unit is percentage.
  • Enable this function the device will detect every 10 seconds. Values in the range 0 to 60 may be set.

The manufacturer defined default value is 5.

This parameter has the configuration ID config_23_1 and is of type INTEGER.

Wakeup Interval

The wakeup interval sets the period at which the device will listen for messages from the controller. This is required for battery devices that sleep most of the time in order to conserve battery life. The device will wake up at this interval and send a message to the controller to tell it that it can accept messages - after a few seconds, it will go back to sleep if there is no further communications.

This setting is defined in seconds. It is advisable not to set this interval too short or it could impact battery life. A period of 1 hour (3600 seconds) is suitable in most instances.

Note that this setting does not affect the devices ability to send sensor data, or notification events.

This parameter has the configuration ID wakeup_interval and is of type INTEGER.

Wakeup Node

When sleeping devices wake up, they send a notification to a listening device. Normally, this device is the network controller, and normally the controller will set this automatically to its own address. In the event that the network contains multiple controllers, it may be necessary to configure this to a node that is not the main controller. This is an advanced setting and should not be changed without a full understanding of the impact.

This parameter has the configuration ID wakeup_node and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The PAT02-B supports 2 association groups.

Group 1: Reports

Association group 1 supports 7 nodes.

Group 2: Light Control

Association group 2 supports 7 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SENSOR_BINARY_V2 Linked to BASIC
COMMAND_CLASS_SENSOR_MULTILEVEL_V5
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_ALARM_V4
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1
COMMAND_CLASS_BATTERY_V1
COMMAND_CLASS_WAKE_UP_V2
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_VERSION_V2
COMMAND_CLASS_MULTI_CMD_V1
COMMAND_CLASS_SECURITY_V1