This describes the Z-Wave device PAT02-A, manufactured by Philio Technology Corp with the thing type UID of philio_pat02a_00_000
.
The device is in the category of Sensor, defining Device used to measure something.
The PAT02-A supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.
The PAT02-A does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. Refer to the Wakeup Information section below for further information.
The flood multisensor PAT02 has flood, temperature and humidity, 3 sensors function in one, based on Z-WaveTM technology. It is the Z-WaveTM plus product, it support the security, OTA... Those newest features of the Z-WaveTM technology. Z-WaveTM is a wireless communication protocol designed for home automation, specifically to remotely control applications in residential and light commercial environments. The technology uses a low-power RF radio embedded or retrofitted into home electronics devices and systems, such as lighting, home access control, entertainment systems and household appliances.
This product can be included and operated in any Z-WaveTM network with other Z-WaveTM certified devices from other manufacturers and/or other applications. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network.
There are one tamper keys in the back side of the device, It can add, remove, reset or association from the Z-WaveTM network.
In the first time, add the device into the Z-WaveTM network. First, make sure the primary controller is in the add mode. And then power on the device, just take out the insulation Mylar in the back side of the device. The device will auto start the NWI (Network Wide Inclusion) mode. And it should be included in 5 seconds. You will see the LED light ON one second.
Notice: Including a node ID allocated by Z-WaveTM Controller means “Add” or “Inclusion”. Excluding a node ID allocated by Z-WaveTM Controller means “Remove” or “Exclusion”.
- Have Z-WaveTM Controller entered inclusion mode.
- Pressing the tamper key three times within 1.5 seconds to enter the inclusion mode.
- After add successful, the device will wake to receive the setting command from Z-WaveTM Controller about 20 seconds.
There are one tamper keys in the back side of the device, It can add, remove, reset or association from the Z-WaveTM network.
In the first time, add the device into the Z-WaveTM network. First, make sure the primary controller is in the add mode. And then power on the device, just take out the insulation Mylar in the back side of the device. The device will auto start the NWI (Network Wide Inclusion) mode. And it should be included in 5 seconds. You will see the LED light ON one second.
Notice: Including a node ID allocated by Z-WaveTM Controller means “Add” or “Inclusion”. Excluding a node ID allocated by Z-WaveTM Controller means “Remove” or “Exclusion”.
- Have Z-WaveTM Controller entered exclusion mode.
- Pressing tamper key three times within 1.5 seconds to enter the exclusion mode. Node ID has been excluded.
The PAT02-A does not permanently listen for messages sent from the controller - it will periodically wake up automatically to check if the controller has messages to send, but will sleep most of the time to conserve battery life. The wakeup period can be configured in the user interface - it is advisable not to make this too short as it will impact battery life - a reasonable compromise is 1 hour.
The wakeup period does not impact the devices ability to report events or sensor data. The device can be manually woken with a button press on the device as described below - note that triggering a device to send an event is not the same as a wakeup notification, and this will not allow the controller to communicate with the device.
After the device adding to the network, it will wake-up once per day in default. When it wake-up it will broadcast the “Wake Up Notification” message to the network, and wake-up 10 seconds for receive the setting commands.
The wake-up interval minimum setting is 30 minutes, and maximum setting is 120 hours. And the interval step is 30 minutes.
Press the tamper key once. The device will wake-up 10 seconds.
The following table summarises the channels available for the PAT02-A -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Binary Sensor | sensor_binary | sensor_binary | Switch | |
Sensor (temperature) | sensor_temperature | sensor_temperature | Temperature | Number:Temperature |
Sensor (relative humidity) | sensor_relhumidity | sensor_relhumidity | Humidity | Number |
Alarm (water) | alarm_flood | alarm_flood | Water | Switch |
Alarm (burglar) | alarm_burglar | alarm_burglar | Door | Switch |
Battery Level | battery-level | system.battery_level | Battery | Number |
Indicates if a sensor has triggered.
The sensor_binary
channel is of type sensor_binary
and supports the Switch
item. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
ON | Triggered |
OFF | Untriggered |
Indicates the current temperature.
The sensor_temperature
channel is of type sensor_temperature
and supports the Number:Temperature
item and is in the Temperature
category.
Indicates the current relative humidity.
The sensor_relhumidity
channel is of type sensor_relhumidity
and supports the Number
item and is in the Humidity
category. This is a read only channel so will only be updated following state changes from the device.
Indicates if the flood alarm is triggered.
The alarm_flood
channel is of type alarm_flood
and supports the Switch
item and is in the Water
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
Indicates if the burglar alarm is triggered.
The alarm_burglar
channel is of type alarm_burglar
and supports the Switch
item and is in the Door
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
The system.battery-level
channel is of type system.battery-level
and supports the Number
item and is in the Battery
category.
This channel provides the battery level as a percentage and also reflects the low battery warning state. If the battery state is in low battery warning state, this will read 0%.
The following table provides a summary of the 12 configuration parameters available in the PAT02-A. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Basic Set OFF Level | Setting the BASIC command value. |
2 | Basic Set ON Level | Setting the BASIC command value. |
5 | Operation Mode | Parameter to set the Operation Mode. |
6 | Multi-Sensor Function Switch | Parameter to set the sensor functions. |
7 | Customer Function | Customer function switch, using bit control. |
10 | Auto Report Battery Time | The interval time for auto reporting the battery level. |
13 | Auto Report Temperature Time | The interval time for auto reporting the temperature state. |
14 | Auto Report Humidity Time | The interval time for auto reporting the humidity state. |
15 | Auto Report Flood Time | The interval time for auto reporting the flood state. |
20 | Auto Report Tick Interval | The interval time for auto report each tick. |
21 | Temperature Differential Report | The temperature differential to report. |
23 | Humidity Differential Report | The humidity differential to report. |
Wakeup Interval | Sets the interval at which the device will accept commands from the controller | |
Wakeup Node | Sets the node ID of the device to receive the wakeup notifications |
Setting the BASIC command value. Setting the BASIC command value.
When the flood trigger off (0x00), send the BASIC CC to the group 2 Values in the range 0 to 255 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
Setting the BASIC command value. Setting the BASIC command value.
When the flood trigger on(0xFF), send the BASIC CC to the group 2. Values in the range 0 to 255 may be set.
The manufacturer defined default value is 255
.
This parameter has the configuration ID config_2_1
and is of type INTEGER
.
Parameter to set the Operation Mode. Parameter to set the Operation Mode.
- Bit 0: Disable the Flood function
- Bit 1: Reserved.
- Bit 2: Reserved.
- Bit 3: Set the temperature scale. 0: Fahrenheit, 1:Celsius
- Bit 4: Reserved.
- Bit 5: Disable the temperature report after event triggered. (1:Disable, 0:Enable)
- Bit 6: Reserved.
- Bit 7: Reserved. The following option values may be configured -:
Value | Description |
---|---|
0 | Fahrenheit + Enable report after event |
8 | Celsius + Enable report after event |
32 | Fahrenheit + Disable report after event |
40 | Celsius + Disable report after event |
The manufacturer defined default value is 0
(Fahrenheit + Enable report after event).
This parameter has the configuration ID config_5_1
and is of type INTEGER
.
Parameter to set the sensor functions. Parameter to set the sensor functions.
- Bit 0: Reserved.
- Bit 1: Reserved.
- Bit 2: Reserved.
- Bit 3: Reserved.
- Bit 4: Reserved.
- Bit 5: Reserved.
- Bit 6: Disable the Values in the range 0 to 127 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_6_1
and is of type INTEGER
.
Customer function switch, using bit control. Customer Function switch using bit control
- Bit 0: Reserve
- Bit 1: Reserve
- Bit 2: Reserve
- Bit 3: Disable send out BASI OFF after flood event cleared
- 0: Enable
- 1: Disable
- Bit 4: Notification Type
- 0: Using Notification Report
- 1: Using Sensor Binary Report
- Bit 5: Disable Multi CC in auto report
- 0: Enable
- 1: Disable
- Bit 6: Disable to report Battery state when the device triggered
- 0: Enable
- 1: Disable
- Bit 7: Reserve The following option values may be configured, in addition to values in the range 0 to 127 -:
Value | Description |
---|---|
16 | Preset: Notification Type = Binary |
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_7_1
and is of type INTEGER
.
The interval time for auto reporting the battery level. The interval time for auto reporting the battery level.
- 0 = Turn off auto report battery.
- 1-127 = Number of ticks. The default value is 12. The tick time can be set by configuration No. 20. Values in the range 0 to 127 may be set.
The manufacturer defined default value is 12
.
This parameter has the configuration ID config_10_1
and is of type INTEGER
.
The interval time for auto reporting the temperature state. The interval time for auto reporting the temperature state.
- 0 = Turn off auto report temperature.
- 1-127 = Number of ticks. The default value is 12. The tick time can be set by configuration No. 20. Values in the range 1 to 127 may be set.
The manufacturer defined default value is 12
.
This parameter has the configuration ID config_13_1
and is of type INTEGER
.
The interval time for auto reporting the humidity state. The interval time for auto reporting the humidity state.
- 0 = Turn off auto report temperature.
- 1-127 = Number of ticks. The default value is 12. The tick time can be set by configuration No. 20. Values in the range 1 to 127 may be set.
The manufacturer defined default value is 12
.
This parameter has the configuration ID config_14_1
and is of type INTEGER
.
The interval time for auto reporting the flood state. The interval time for auto reporting the flood state.
- 0 = Turn off auto report temperature.
- 1-127 = Number of ticks. The default value is 12. The tick time can be set by configuration No. 20. Values in the range 1 to 127 may be set.
The manufacturer defined default value is 12
.
This parameter has the configuration ID config_15_1
and is of type INTEGER
.
The interval time for auto report each tick. The interval time for auto report each tick. Setting configuration will affect configuration no. 10, 13, 14 and 15.
- 0 = Caution: Setting to 0 means turn off all auto report function.
- 1-254 = Caution: The value is unsigned byt Values in the range 0 to 254 may be set.
The manufacturer defined default value is 30
.
This parameter has the configuration ID config_20_1
and is of type INTEGER
.
The temperature differential to report. The temperature differential to report. The unit is Fahrenheit. Enable this function the device will detect every 10 seconds.
- 0 = means turn off this function. Values in the range 0 to 127 may be set.
The manufacturer defined default value is 1
.
This parameter has the configuration ID config_21_1
and is of type INTEGER
.
The humidity differential to report. The humidity differential to report. The unit is percentage. Enable this function the device will detect every 10 seconds.
- 0 = means turn off this function. Values in the range 0 to 60 may be set.
The manufacturer defined default value is 5
.
This parameter has the configuration ID config_23_1
and is of type INTEGER
.
The wakeup interval sets the period at which the device will listen for messages from the controller. This is required for battery devices that sleep most of the time in order to conserve battery life. The device will wake up at this interval and send a message to the controller to tell it that it can accept messages - after a few seconds, it will go back to sleep if there is no further communications.
This setting is defined in seconds. It is advisable not to set this interval too short or it could impact battery life. A period of 1 hour (3600 seconds) is suitable in most instances.
Note that this setting does not affect the devices ability to send sensor data, or notification events.
This parameter has the configuration ID wakeup_interval
and is of type INTEGER
.
When sleeping devices wake up, they send a notification to a listening device. Normally, this device is the network controller, and normally the controller will set this automatically to its own address. In the event that the network contains multiple controllers, it may be necessary to configure this to a node that is not the main controller. This is an advanced setting and should not be changed without a full understanding of the impact.
This parameter has the configuration ID wakeup_node
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The PAT02-A supports 2 association groups.
Association group 1 supports 7 nodes.
Association group 2 supports 7 nodes.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SENSOR_BINARY_V2 | Linked to BASIC |
COMMAND_CLASS_SENSOR_MULTILEVEL_V5 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_ALARM_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_BATTERY_V1 | |
COMMAND_CLASS_WAKE_UP_V2 | |
COMMAND_CLASS_ASSOCIATION_V1 | |
COMMAND_CLASS_VERSION_V1 | |
COMMAND_CLASS_MULTI_CMD_V1 |