This describes the Z-Wave device PAN11, manufactured by Philio Technology Corp with the thing type UID of philio_pan11_00_000
.
The device is in the category of Power Outlet, defining Small devices to be plugged into a power socket in a wall which stick there.
The PAN11 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
This smart energy plug-in switch is able to detect voltage, current, power factor, Instant power wattage (53150W) and overload wattage (30103300W) of connected light or appliances. When detecting overload state, the Module will be disabled and its On/Off button will be lockout of which LED will flash quickly for 30 seconds. However, unplug and re-connect the Module will reset its overload condition to normal status.
This plug-in switch can active sent out instant power wattage when variation over 5% or active sent out state change when manually push the ON/OFF button , this allows the controller to avoid polling the reading wattage value and state of the switch and can increase the efficiency of controlle
Tripple Click the button on the device confirms inclusion and exclusion.
Tripple Click the button on the device confirms inclusion and exclusion.
The following table summarises the channels available for the PAN11 -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Switch | switch_binary | switch_binary | Switch | Switch |
Electric meter (power factor) | meter_powerfactor | meter_powerfactor | Energy | Number |
Electric meter (amps) | meter_current | meter_current | Energy | Number |
Electric meter (kWh) | meter_kwh | meter_kwh | Energy | Number |
Electric meter (volts) | meter_voltage | meter_voltage | Energy | Number |
Electric meter (watts) | meter_watts | meter_watts | Energy | Number |
Reset the total power consumption | meter_reset | meter_reset | Energy | Switch |
Alarm | alarm_general | alarm_general | Alarm | Switch |
Switch the power on and off.
The switch_binary
channel is of type switch_binary
and supports the Switch
item and is in the Switch
category.
Indicates the instantaneous power factor.
The meter_powerfactor
channel is of type meter_powerfactor
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous current consumption.
The meter_current
channel is of type meter_current
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the energy consumption (kWh).
The meter_kwh
channel is of type meter_kwh
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous voltage.
The meter_voltage
channel is of type meter_voltage
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous power consumption.
The meter_watts
channel is of type meter_watts
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Reset the meter.
The meter_reset
channel is of type meter_reset
and supports the Switch
item and is in the Energy
category.
Indicates if an alarm is triggered.
The alarm_general
channel is of type alarm_general
and supports the Switch
item and is in the Alarm
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
The following table provides a summary of the 9 configuration parameters available in the PAN11. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | W meter report period | Set automatic W meter reporting interval |
2 | kWh meter report period | Set automatic kWh meter reporting interval. |
3 | Threshold of Watt for load caution | Set threshold of wattage meter value for load caution . |
4 | Threshold of kWh for Load Caution | If threshold of kWh is reached, a Meter Report will be generated |
5 | Restore switch state mode | |
6 | Mode of switch Off function | |
7 | LED indication mode | |
8 | Auto Off Timer | Auto off timer. 0 will disable the auto off function. |
9 | RF Off command mode | |
Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands |
Set automatic W meter reporting interval If the setting is configured for 1hour (set value =720), the PAN11 will report its instant power consumption every 1 hour to Group1 node. The maximum interval to report its instant power consumption is 45 hours (5s*32767/3600=45hr). Values in the range 0 to 32767 may be set.
The manufacturer defined default value is 720
.
This parameter has the configuration ID config_1_2
and is of type INTEGER
.
Set automatic kWh meter reporting interval. If the setting is configured for 1hour (set value =6), the PAN11 will report its Accumulated Power Consumption (KW/h) every 1 hour to Group1 node. The maximum interval to report its Accumulated Power Consumption (KW/h) is 227.55 days (10min*32767/1440=227.55 days). Values in the range 0 to 32767 may be set.
The manufacturer defined default value is 6
.
This parameter has the configuration ID config_2_2
and is of type INTEGER
.
Set threshold of wattage meter value for load caution . This is a warning when the current of load over the preset threshold value, if the setting value is 1300, when the load current of Relay1 over this value, PAN11 will send current meter report to warn the Group1 node, the Range of the setting value is from 10 to 1300,and the default value is 1300. Values in the range 10 to 1300 may be set.
The manufacturer defined default value is 1300
.
This parameter has the configuration ID config_3_2
and is of type INTEGER
.
If threshold of kWh is reached, a Meter Report will be generated Enable automatic warning when the accumulated kWh power consumption exceeds the setting value from 1KWh ~ 10000KWh.. Set to 0 will disable kWh load caution reporting. Values in the range 1 to 10000 may be set.
The manufacturer defined default value is 10000
.
This parameter has the configuration ID config_4_2
and is of type INTEGER
.
The following option values may be configured -:
Value | Description |
---|---|
0 | Switch Off |
1 | Last State |
2 | Switch On |
The manufacturer defined default value is 1
(Last State).
This parameter has the configuration ID config_5_1
and is of type INTEGER
.
The following option values may be configured -:
Value | Description |
---|---|
0 | SWITCH OFF commands received are ignored. |
1 | SWITCH OFF commands received are honored. |
The manufacturer defined default value is 1
(SWITCH OFF commands received are honored.).
This parameter has the configuration ID config_6_1
and is of type INTEGER
.
The following option values may be configured -:
Value | Description |
---|---|
1 | The LED follows the state of the switch. |
2 | LED off with load ON |
3 | One flash mode |
The manufacturer defined default value is 1
(The LED follows the state of the switch.).
This parameter has the configuration ID config_7_1
and is of type INTEGER
.
Auto off timer. 0 will disable the auto off function.
Values in the range 0 to 255 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_8_2
and is of type INTEGER
.
The following option values may be configured -:
Value | Description |
---|---|
0 | Switch Off |
1 | Ignore |
2 | Switch Toggle |
3 | Switch On |
The manufacturer defined default value is 0
(Switch Off).
This parameter has the configuration ID config_9_1
and is of type INTEGER
.
Set the mode for the switch when receiving SWITCH ALL commands.
The following option values may be configured -:
Value | Description |
---|---|
0 | Exclude from All On and All Off groups |
1 | Include in All On group |
2 | Include in All Off group |
255 | Include in All On and All Off groups |
This parameter has the configuration ID switchall_mode
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The PAN11 supports 1 association group.
Association group 1 supports 1 node.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_SWITCH_ALL_V1 | |
COMMAND_CLASS_METER_V3 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V2 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_ALARM_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_PROTECTION_V2 | |
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V1 | |
COMMAND_CLASS_SECURITY_V1 |
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.