PAN11 Smart Energy Plug In Switch

This describes the Z-Wave device PAN11, manufactured by Philio Technology Corp with the thing type UID of philio_pan11_00_000.

The device is in the category of Power Outlet, defining Small devices to be plugged into a power socket in a wall which stick there.

PAN11 product image

The PAN11 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

This smart energy plug-in switch is able to detect voltage, current, power factor, Instant power wattage (53150W) and overload wattage (30103300W) of connected light or appliances. When detecting overload state, the Module will be disabled and its On/Off button will be lockout of which LED will flash quickly for 30 seconds. However, unplug and re-connect the Module will reset its overload condition to normal status.

This plug-in switch can active sent out instant power wattage when variation over 5% or active sent out state change when manually push the ON/OFF button , this allows the controller to avoid polling the reading wattage value and state of the switch and can increase the efficiency of controlle

Inclusion Information

Tripple Click the button on the device confirms inclusion and exclusion.

Exclusion Information

Tripple Click the button on the device confirms inclusion and exclusion.

Channels

The following table summarises the channels available for the PAN11 -:

Channel Name Channel ID Channel Type Category Item Type
Switch switch_binary switch_binary Switch Switch
Electric meter (power factor) meter_powerfactor meter_powerfactor Energy Number
Electric meter (amps) meter_current meter_current Energy Number
Electric meter (kWh) meter_kwh meter_kwh Energy Number
Electric meter (volts) meter_voltage meter_voltage Energy Number
Electric meter (watts) meter_watts meter_watts Energy Number
Reset the total power consumption meter_reset meter_reset Energy Switch
Alarm alarm_general alarm_general Alarm Switch

Switch

Switch the power on and off.

The switch_binary channel is of type switch_binary and supports the Switch item and is in the Switch category.

Electric meter (power factor)

Indicates the instantaneous power factor.

The meter_powerfactor channel is of type meter_powerfactor and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (amps)

Indicates the instantaneous current consumption.

The meter_current channel is of type meter_current and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (kWh)

Indicates the energy consumption (kWh).

The meter_kwh channel is of type meter_kwh and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (volts)

Indicates the instantaneous voltage.

The meter_voltage channel is of type meter_voltage and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (watts)

Indicates the instantaneous power consumption.

The meter_watts channel is of type meter_watts and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Reset the total power consumption

Reset the meter.

The meter_reset channel is of type meter_reset and supports the Switch item and is in the Energy category.

Alarm

Indicates if an alarm is triggered.

The alarm_general channel is of type alarm_general and supports the Switch item and is in the Alarm category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Device Configuration

The following table provides a summary of the 9 configuration parameters available in the PAN11. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 W meter report period Set automatic W meter reporting interval
2 kWh meter report period Set automatic kWh meter reporting interval.
3 Threshold of Watt for load caution Set threshold of wattage meter value for load caution .
4 Threshold of kWh for Load Caution If threshold of kWh is reached, a Meter Report will be generated
5 Restore switch state mode
6 Mode of switch Off function
7 LED indication mode
8 Auto Off Timer Auto off timer. 0 will disable the auto off function.
9 RF Off command mode
Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Parameter 1: W meter report period

Set automatic W meter reporting interval If the setting is configured for 1hour (set value =720), the PAN11 will report its instant power consumption every 1 hour to Group1 node. The maximum interval to report its instant power consumption is 45 hours (5s*32767/3600=45hr). Values in the range 0 to 32767 may be set.

The manufacturer defined default value is 720.

This parameter has the configuration ID config_1_2 and is of type INTEGER.

Parameter 2: kWh meter report period

Set automatic kWh meter reporting interval. If the setting is configured for 1hour (set value =6), the PAN11 will report its Accumulated Power Consumption (KW/h) every 1 hour to Group1 node. The maximum interval to report its Accumulated Power Consumption (KW/h) is 227.55 days (10min*32767/1440=227.55 days). Values in the range 0 to 32767 may be set.

The manufacturer defined default value is 6.

This parameter has the configuration ID config_2_2 and is of type INTEGER.

Parameter 3: Threshold of Watt for load caution

Set threshold of wattage meter value for load caution . This is a warning when the current of load over the preset threshold value, if the setting value is 1300, when the load current of Relay1 over this value, PAN11 will send current meter report to warn the Group1 node, the Range of the setting value is from 10 to 1300,and the default value is 1300.  Values in the range 10 to 1300 may be set.

The manufacturer defined default value is 1300.

This parameter has the configuration ID config_3_2 and is of type INTEGER.

Parameter 4: Threshold of kWh for Load Caution

If threshold of kWh is reached, a Meter Report will be generated Enable automatic warning when the accumulated kWh power consumption exceeds the setting value from 1KWh ~ 10000KWh.. Set to 0 will disable kWh load caution reporting. Values in the range 1 to 10000 may be set.

The manufacturer defined default value is 10000.

This parameter has the configuration ID config_4_2 and is of type INTEGER.

Parameter 5: Restore switch state mode

The following option values may be configured -:

Value Description
0 Switch Off
1 Last State
2 Switch On

The manufacturer defined default value is 1 (Last State).

This parameter has the configuration ID config_5_1 and is of type INTEGER.

Parameter 6: Mode of switch Off function

The following option values may be configured -:

Value Description
0 SWITCH OFF commands received are ignored.
1 SWITCH OFF commands received are honored.

The manufacturer defined default value is 1 (SWITCH OFF commands received are honored.).

This parameter has the configuration ID config_6_1 and is of type INTEGER.

Parameter 7: LED indication mode

The following option values may be configured -:

Value Description
1 The LED follows the state of the switch.
2 LED off with load ON
3 One flash mode

The manufacturer defined default value is 1 (The LED follows the state of the switch.).

This parameter has the configuration ID config_7_1 and is of type INTEGER.

Parameter 8: Auto Off Timer

Auto off timer. 0 will disable the auto off function.

Values in the range 0 to 255 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_8_2 and is of type INTEGER.

Parameter 9: RF Off command mode

The following option values may be configured -:

Value Description
0 Switch Off
1 Ignore
2 Switch Toggle
3 Switch On

The manufacturer defined default value is 0 (Switch Off).

This parameter has the configuration ID config_9_1 and is of type INTEGER.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -:

Value Description
0 Exclude from All On and All Off groups
1 Include in All On group
2 Include in All Off group
255 Include in All On and All Off groups

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The PAN11 supports 1 association group.

Group 1: Reports

Association group 1 supports 1 node.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC
COMMAND_CLASS_SWITCH_ALL_V1
COMMAND_CLASS_METER_V3
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V2
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_ALARM_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_PROTECTION_V2
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_VERSION_V1
COMMAND_CLASS_SECURITY_V1

Documentation Links