{% include base.html %}

PAN08 Roller shutter controller

This describes the Z-Wave device PAN08, manufactured by Philio Technology Corp with the thing type UID of philio_pan081a_00_000.

The device is in the category of Blinds, defining Roller shutters, window blinds, etc..

PAN08 product image

The PAN08 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

The in-wall Roller Shutter Controller is designed to switch rise/lower roller shutter connected to its terminals using radio waves, controllers and a push button directly connected to this Roller Controller.

This in-wall Roller Shutter Controller is a transceiver which is a Z-Wave Plus enabled device and is fully compatible with any Z-Wave enabled network. Slim design let the Controller can easily hide itself into the wall box and that will be good for the house decoration.

The new smart relay calibration technology can reduce the inrush current caused by the load and let the module work perfectly with many kind of Roller Shutter. This in-wall Roller Shutter Controller is able to detect position of the Shutter by using the patterned power measuring method, so it can be remote controlled not only fully up or down , but also can be adjusted to ex. 30% or 50%. And when manual controlled by push button, the controller also can memorize the position and send the new shutter position to its controller (ex. IP-Gateway).

Inclusion Information

In the front casing, there is an include button with LED indicator below which is used to carry out inclusion, exclusion, reset or association. When first power is applied, its LED flashes on and off alternately and repeatedly at 0.5 second intervals. It implies that it has not been assigned a node ID and start auto inclusion.

The function of auto inclusion will be executed as long as the PAN08 does not have Node ID and just connect the PAN08 to main power.

Note: Auto inclusion timeout is 2 minute during which the node information of explorer frame will be emitted once every several seconds.

Exclusion Information

 Put your Z-Wave controller into exclusion mode by following the instructions provided by the controller manufacturer.

 Pressing Include button three times within 2 seconds will enter exclusion mode.

Channels

The following table summarises the channels available for the PAN08 -:

Channel Name Channel ID Channel Type Category Item Type
Blinds Control blinds_control blinds_control Blinds Rollershutter
Scene Number scene_number scene_number Number
Electric meter (watts) meter_watts meter_watts Energy Number
Electric meter (power factor) meter_powerfactor meter_powerfactor Energy Number
Electric meter (kWh) meter_kwh meter_kwh Energy Number
Electric meter (amps) meter_current meter_current Energy Number
Electric meter (volts) meter_voltage meter_voltage Energy Number
Clear Accumulated Energy meter_reset meter_reset Energy Switch
Alarm alarm_general alarm_general Alarm Switch

Blinds Control

Provides start / stop control of blinds.

The blinds_control channel is of type blinds_control and supports the Rollershutter item and is in the Blinds category.

Scene Number

Triggers when a scene button is pressed.

The scene_number channel is of type scene_number and supports the Number item.

Electric meter (watts)

Indicates the instantaneous power consumption.

The meter_watts channel is of type meter_watts and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (power factor)

Indicates the instantaneous power factor.

The meter_powerfactor channel is of type meter_powerfactor and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (kWh)

Indicates the energy consumption (kWh).

The meter_kwh channel is of type meter_kwh and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (amps)

Indicates the instantaneous current consumption.

The meter_current channel is of type meter_current and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (volts)

Indicates the instantaneous voltage.

The meter_voltage channel is of type meter_voltage and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Clear Accumulated Energy

Reset the meter.

The meter_reset channel is of type meter_reset and supports the Switch item and is in the Energy category.

Alarm

Indicates if an alarm is triggered.

The alarm_general channel is of type alarm_general and supports the Switch item and is in the Alarm category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Device Configuration

The following table provides a summary of the 6 configuration parameters available in the PAN08. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Watt meter report interval (5s) Interval (x5 seconds) to send out watt meter report
2 KWH Meter Report Interval (10min) Interval (x10 minutes) to send out KWH Meter Report
3 Threshold for Load Caution (10mA) Threshold (x0.01A) of current for Load Caution
4 Threshold of KWh for Load Caution
5 External SwitchType Sets the type of an external switch
6 Level report mode Sets the way the controller reports the shutter level

Parameter 1: Watt meter report interval (5s)

Interval (x5 seconds) to send out watt meter report

Values in the range 1 to 32767 may be set.

The manufacturer defined default value is 720.

This parameter has the configuration ID config_1_2 and is of type INTEGER.

Parameter 2: KWH Meter Report Interval (10min)

Interval (x10 minutes) to send out KWH Meter Report

Values in the range 1 to 32767 may be set.

The manufacturer defined default value is 6.

This parameter has the configuration ID config_2_2 and is of type INTEGER.

Parameter 3: Threshold for Load Caution (10mA)

Threshold (x0.01A) of current for Load Caution

Values in the range 1 to 1100 may be set.

The manufacturer defined default value is 500.

This parameter has the configuration ID config_3_2 and is of type INTEGER.

Parameter 4: Threshold of KWh for Load Caution

Values in the range 1 to 10000 may be set.

The manufacturer defined default value is 10000.

This parameter has the configuration ID config_4_2 and is of type INTEGER.

Parameter 5: External SwitchType

Sets the type of an external switch 1: One Push button

2: Two push bittons Values in the range 1 to 2 may be set.

The manufacturer defined default value is 2.

This parameter has the configuration ID config_5_1 and is of type INTEGER.

Parameter 6: Level report mode

Sets the way the controller reports the shutter level 1: Report destination level in 5s

2: Report 10 percent level while running Values in the range 1 to 2 may be set.

The manufacturer defined default value is 2.

This parameter has the configuration ID config_6_1 and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The PAN08 supports 1 association group.

Group 1: Blind Control

Association group 1 supports 1 node.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1
COMMAND_CLASS_SWITCH_MULTILEVEL_V3
COMMAND_CLASS_SCENE_ACTIVATION_V1
COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1
COMMAND_CLASS_METER_V3
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_ALARM_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_VERSION_V2

Documentation Links