Skip to content

Latest commit

 

History

History
executable file
·
302 lines (198 loc) · 9.65 KB

pan06_1_8.md

File metadata and controls

executable file
·
302 lines (198 loc) · 9.65 KB
layout title
documentation
PAN06 - ZWave

{% include base.html %}

PAN06 In Wall Dual Relay (1 Way) Switch Module 2 x 1.5kW

This describes the Z-Wave device PAN06, manufactured by Philio Technology Corp with the thing type UID of philio_pan06_01_008. This version of the device is limited to firmware versions above 1.8

The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.

PAN06 product image

The PAN06 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

The PAN06 allows controlling two independent loads both wirelessly via Z-Wave and locally utilizing a traditional wall switch. Thanks to its calibration technology the device cannot only be used to switch resistive devices but also works perfectly with many kind of reactive or resistive loads such as fluorescent lights or LEDs.

The device is placed in a wall box right behind the normal switch. The switch is not longer directly connected to the load but acts as input device for the insert that is controlling the load. This device is designed for a 3 wire system and needs a neutral wire in the wall box.

Inclusion Information

  1. Have Z-Wave Controller entered inclusion mode.
  2. Pressing Include button of PAN06 three times within 2 seconds will enter inclusion mode

Exclusion Information

  1. Have Z-Wave Controller entered exclusion mode.
  2. Pressing Include button of PAN06 three times within 2 seconds will enter exclusion mode

Channels

The following table summarises the channels available for the PAN06 -:

Channel Name Channel ID Channel Type Category Item Type
Switch switch_binary switch_binary Switch Switch
Scene Number scene_number scene_number Number
Alarm alarm_general alarm_general Alarm Switch
Switch 1 switch_binary1 switch_binary Switch Switch
Switch 2 switch_binary2 switch_binary Switch Switch
Switch 3 switch_binary3 switch_binary Switch Switch

Switch

Switch the power on and off.

The switch_binary channel is of type switch_binary and supports the Switch item and is in the Switch category.

Scene Number

Triggers when a scene button is pressed.

The scene_number channel is of type scene_number and supports the Number item.

Alarm

Indicates if an alarm is triggered.

The alarm_general channel is of type alarm_general and supports the Switch item and is in the Alarm category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Switch 1

Switch the power on and off.

The switch_binary1 channel is of type switch_binary and supports the Switch item and is in the Switch category.

Switch 2

Switch the power on and off.

The switch_binary2 channel is of type switch_binary and supports the Switch item and is in the Switch category.

Switch 3

Switch the power on and off.

The switch_binary3 channel is of type switch_binary and supports the Switch item and is in the Switch category.

Device Configuration

The following table provides a summary of the 6 configuration parameters available in the PAN06. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Selected endpoint Send Basic Command Class
2 Switch mode Change the external switch mode
3 Restore Switch State Mode Switch state after repowering
4 Auto OFF Timer
5 RF OFF command RF OFF command mode
6 Existence of endpoint 3
Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Parameter 1: Selected endpoint

Send Basic Command Class If Controller not using Multi_Channel command class to access the endpoint of PAN06, you may configure the endpoint value to react the Basic Command Class The following option values may be configured -:

Value Description
1 Relay 1
2 Relay 2
3 Relay 1+2

The manufacturer defined default value is 3 (Relay 1+2).

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Parameter 2: Switch mode

Change the external switch mode

The following option values may be configured -:

Value Description
1 Edge mode
2 Pulse mode
3 Edge-Toggle mode

The manufacturer defined default value is 1 (Edge mode).

This parameter has the configuration ID config_2_1 and is of type INTEGER.

Parameter 3: Restore Switch State Mode

Switch state after repowering 0 : Switch off
1 : Last switch state
2 : Switch on

Whenever the AC power return from lost, PAN06 will restore the switch state which
could be SWITCH OFF、 LAST SWITCH STATE、 SWITCH ON. The default setting is
LAST SWITCH STATE The following option values may be configured -:

Value Description
0 Switch OFF
1 Last Switch state
2 Switch ON

The manufacturer defined default value is 1 (Last Switch state).

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Parameter 4: Auto OFF Timer

Values in the range 0 to 32767 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_4_2 and is of type INTEGER.

Parameter 5: RF OFF command

RF OFF command mode Whenever a switch off command, BASIC_SET 、BINARY_SWITCH_SET 、
SWITCH_ALL_OFF, is received, it could be interpreted as 4 variety of commands.
3-5-1 Switch Off:It switches to OFF state. The default setting is Switch Off.
3-5-2 Ignore:The switch off command will be ignored.
3-5-3 Switch Toggle:It switches to the inverse of current state.
3-5-4 Switch On:It switches to ON state.

0 : Switch off
1 : Ignore
2 : Switch toggle
3 : Switch on The following option values may be configured -:

Value Description
0 Switch OFF
1 Ignore
2 Switch toggle
3 Switch on

The manufacturer defined default value is 0 (Switch OFF).

This parameter has the configuration ID config_5_1 and is of type INTEGER.

Parameter 6: Existence of endpoint 3

The following option values may be configured -:

Value Description
1 Endpoint 3 exists
2 No endpoint 3

The manufacturer defined default value is 1 (Endpoint 3 exists).

This parameter has the configuration ID config_6_1 and is of type INTEGER.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -:

Value Description
0 Exclude from All On and All Off groups
1 Include in All On group
2 Include in All Off group
255 Include in All On and All Off groups

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The PAN06 supports 3 association groups.

Group 1: Relay 1 + 2

Association group 1 supports 1 node.

Group 2: Relay 1

Association group 2 supports 1 node.

Group 3: Relay 2

Association group 3 supports 1 node.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC
COMMAND_CLASS_SWITCH_ALL_V1
COMMAND_CLASS_SCENE_ACTIVATION_V1
COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1
COMMAND_CLASS_SENSOR_MULTILEVEL_V1
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_MULTI_CHANNEL_V2
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_ALARM_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_PROTECTION_V2
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_VERSION_V2

Endpoint 1

Command Class Comment
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC

Endpoint 2

Command Class Comment
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC

Endpoint 3

Command Class Comment
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC

Documentation Links


Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.