This describes the Z-Wave device PAN03, manufactured by Philio Technology Corp with the thing type UID of philio_pan03_00_000
.
The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.
The PAN03 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
This plug-in ON/OFF switch PAN03 is a security enabled wireless switch, based on Z-Wave Plus technology. Z-Wave PlusTM enabled devices displaying the Z-Wave PlusTM logo can also be used with it regardless of the manufacturer, and can also be used in other manufacturer’s Z-WaveTM enabled networks. Remote On/Off control of the connected load is possible with other manufacturer’s wireless Controller. Each switch is designed to act as a repeater. Repeaters will re-transmit the RF signal to ensure that the signal is received by its intended destination by routing the signal around obstacles and radio dead spots. Because PAN03 supports Security Command Class, it can learn with Secured controller. Its functionality and supported command classes is identical when included as a secure and non-secure device.
-
Put your Z-Wave controller into inclusion mode by following the instructions provided by the controller manufacturer.
-
Pressing On/Off button three times within 2 seconds will enter inclusion mode.
-
Put your Z-Wave controller into exclusion mode by following the instructions provided by the controller manufacturer.
-
Pressing On/Off button three times within 2 seconds will enter exclusion mode.
Node ID has been excluded.
The following table summarises the channels available for the PAN03 -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Switch | switch_binary | switch_binary | Switch | Switch |
Electric meter (watts) | meter_watts | meter_watts | Energy | Number |
Electric meter (power factor) | meter_powerfactor | meter_powerfactor | Energy | Number |
Electric meter (volts) | meter_voltage | meter_voltage | Energy | Number |
Electric meter (amps) | meter_current | meter_current | Energy | Number |
Electric meter (kWh) | meter_kwh | meter_kwh | Energy | Number |
Alarm | alarm_general | alarm_general | Alarm | Switch |
Switch the power on and off.
The switch_binary
channel is of type switch_binary
and supports the Switch
item and is in the Switch
category.
Indicates the instantaneous power consumption.
The meter_watts
channel is of type meter_watts
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous power factor.
The meter_powerfactor
channel is of type meter_powerfactor
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous voltage.
The meter_voltage
channel is of type meter_voltage
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the instantaneous current consumption.
The meter_current
channel is of type meter_current
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the energy consumption (kWh).
The meter_kwh
channel is of type meter_kwh
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates if an alarm is triggered.
The alarm_general
channel is of type alarm_general
and supports the Switch
item and is in the Alarm
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
The following table provides a summary of the 11 configuration parameters available in the PAN03. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Watt Meter Report Period | Watt Meter Report Period |
2 | KWH Meter Report Period | KWH Meter Report Period (6*10min=1 hour) |
3 | Threshold of current for Load caution | Threshold of current for Load caution (1100*0.01A = 11A) |
4 | Threshold of KWh for Load caution | Threshold of KWh for Load caution |
5 | Restore switch state mode | Restore switch state mode |
6 | Manual On/Off mode | Manual On/Off mode |
7 | LED indication mode | LED indication mode |
8 | Auto off timer | Auto off timer |
9 | RF off command mode | RF off command mode |
10 | Switch mode | Edge or Pulse mode or Edge-Toggle mode |
11 | Manual Switch Report mode | Manual Switch Report mode |
Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands |
Watt Meter Report Period WATT METER REPORT PERIOD:
If the setting is configured for 1hour (set value =720), the Micromodule Single Switch Max.Load: 11A will report its instant power consumption every 1 hour to Group1 node. The maximum interval to report its instant power consumption is 45 hours (5s*32767/3600=45hr). Values in the range 1 to 32767 may be set.
The manufacturer defined default value is 720
.
This parameter has the configuration ID config_1_2
and is of type INTEGER
.
KWH Meter Report Period (6*10min=1 hour) KWH METER REPORT PERIOD:
If the setting is configured for 1hour (set value =6), the Micromodule Single Switch Max.Load: 11A will report its Accumulated Power Consumption (KW/h) every 1 hour to Group1 node. The maximum interval to report its Accumulated Power Consumption (KW/h) is 227.55 days (10min*32767/1440=227.55 days). Values in the range 1 to 32767 may be set.
The manufacturer defined default value is 6
.
This parameter has the configuration ID config_2_2
and is of type INTEGER
.
Threshold of current for Load caution (1100*0.01A = 11A) THRESHOLD OF CURRENT FOR LOAD CAUTION:
This is a warning when the current of load over the preset threshold value, if the setting value is 1100, when the load current of Relay1 over this value, Micromodule Single Switch Max.Load: 11A will send current meter report to warn the Group1 node, the Range of the setting value is from 10 to 1100, and the default value is 1100. Values in the range 10 to 1100 may be set.
The manufacturer defined default value is 1100
.
This parameter has the configuration ID config_3_2
and is of type INTEGER
.
Threshold of KWh for Load caution THRESHOLD OF KWH FOR LOAD CAUTION
This is a warning when the KWh of load over the preset threshold value, if the setting value is 10000, when the Accumulated Power Consumption of Relay1 over this value, Micromodule Single Switch Max.Load: 11A will send KWH meter report to warn the Group1 node, minimum value is 1KWh and default value is 10000 kWh Values in the range 10 to 10000 may be set.
The manufacturer defined default value is 10000
.
This parameter has the configuration ID config_4_2
and is of type INTEGER
.
Restore switch state mode RESTORE SWITCH STATE MODE:
Whenever the AC power return from lost, Micromodule Single Switch Max.Load: 11A will restore the switch state which could be SWITCH OFF, LAST SWITCH STATE, SWITCH ON. The default setting is LAST SWITCH STATE. The following option values may be configured -:
Value | Description |
---|---|
0 | Switch off |
1 | Last switch state |
2 | Switch on |
The manufacturer defined default value is 1
(Last switch state).
This parameter has the configuration ID config_5_1
and is of type INTEGER
.
Manual On/Off mode MANUAL ON/OFF MODE:
The On/Off function of S1, S2 and learn switch can be disabled or enabled by this parameter, default value is Enable. But the learning operation won’t be affected. When manual On/Off function is disabled, the RF command can only switch On but not Off. This is useful function for keeping the device in switch on state The following option values may be configured -:
Value | Description |
---|---|
0 | Disable manual On/Off |
1 | Enable manual On/Off |
The manufacturer defined default value is 0
(Disable manual On/Off).
This parameter has the configuration ID config_6_1
and is of type INTEGER
.
LED indication mode
The following option values may be configured -:
Value | Description |
---|---|
1 | Show switch state |
2 | Show night mode |
2 | One flash mode |
The manufacturer defined default value is 1
(Show switch state).
This parameter has the configuration ID config_7_1
and is of type INTEGER
.
Auto off timer AUTO OFF TIMER:
Whenever Micromodule Single Switch Max.Load: 11A switches to on, the auto off timer begin to count down. After the timer decrease to zero, it will switch to off automatically. However if Auto off timer is set as 0, the auto off function will be disabled. The default setting is 0. Values in the range 0 to 32767 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_8_2
and is of type INTEGER
.
RF off command mode RF OFF COMMAND MODE:
Whenever a switch off command, BASIC_SET, BINARY_SWITCH_SET, SWITCH_ALL_OFF, is received, it could be interpreted as 4 variety of commands. The following option values may be configured -:
Value | Description |
---|---|
0 | Switch off |
1 | Ignore |
2 | Switch toggle |
3 | Switch on |
The manufacturer defined default value is 0
(Switch off).
This parameter has the configuration ID config_9_1
and is of type INTEGER
.
Edge or Pulse mode or Edge-Toggle mode
The following option values may be configured -:
Value | Description |
---|---|
1 | Edge mode |
2 | Pulse mode |
3 | Edge-Toggle mode |
The manufacturer defined default value is 1
(Edge mode).
This parameter has the configuration ID config_10_1
and is of type INTEGER
.
Manual Switch Report mode Whenever PAN03 is manually switch on or off, it will send BINARY_SWITCH_ REPORT to the node of group1. The default setting is Enable the function. The following option values may be configured -:
Value | Description |
---|---|
0 | Disable |
1 | Enable |
The manufacturer defined default value is 1
(Enable).
This parameter has the configuration ID config_11_1
and is of type INTEGER
.
Set the mode for the switch when receiving SWITCH ALL commands.
The following option values may be configured -:
Value | Description |
---|---|
0 | Exclude from All On and All Off groups |
1 | Include in All On group |
2 | Include in All Off group |
255 | Include in All On and All Off groups |
This parameter has the configuration ID switchall_mode
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The PAN03 supports 1 association group.
the Switch will report its latest status to Z-Wave Controller Grouping 1 includes, SWITCH_BINARY_REPORT, METER_REPORT, ALARM_REPORT.
Association group 1 supports 1 node.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_SWITCH_ALL_V1 | |
COMMAND_CLASS_METER_V3 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_ALARM_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_PROTECTION_V2 | |
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V2 | |
COMMAND_CLASS_SECURITY_V1 |