This describes the Z-Wave device PSC132ZW, manufactured by permundo GmbH with the thing type UID of permundo_psc132zw_00_000
.
The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.
The PSC132ZW supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
The wireless flush-mount switching actuator PSC132ZW allows you to remotely control electrical appliances. It features a metering function to measure the power consumption and the accumulated energy usage of connected equipment. The built-in metering unit is of high quality: it calculates the true-power and also works for small loads from 1W upwards. This feature is important to have a correct measurement value also for electronic loads like led lamps.
The PSC132ZW has a built-in safety features that will switch-off the output in case of too high temperature or overload.
Additionally the PSC132 has a feature to switch the load on at zero voltage and switch the load off at zero current. This leads to a very high number of possible switching cycles also for difficult loads like led-lamps or motors, e.g. pumps.
When a PS132ZW that is not associated to a Z-Wave network is inserted into the mains outlet, it will flash once red followed by 2 green flashes followed by steady red flashing. The PSC132ZW can now be added to (=inclusion) or removed from (=exclusion) a Z-Wave network:
- start inclusion/exclusion on the primary controller
- hold the touch button until the led shows green light
- release the touch button
The PSC132ZW will confirm successful addition to the network by 5 green flashes.
When a PS132ZW that is not associated to a Z-Wave network is inserted into the mains outlet, it will flash once red followed by 2 green flashes followed by steady red flashing. The PSC132ZW can now be added to (=inclusion) or removed from (=exclusion) a Z-Wave network:
- start inclusion/exclusion on the primary controller
- hold the touch button until the led shows green light
- release the touch button
The PSC132ZW will confirm successful removal/exclusion by steady red flashing. At the time of exclusion the device is factory reset.
The following table summarises the channels available for the PSC132ZW -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Switch | switch_binary | switch_binary | Switch | Switch |
Electric meter (watts) | meter_watts | meter_watts | Energy | Number |
Electric meter (kWh) | meter_kwh | meter_kwh | Energy | Number |
Switch the power on and off.
The switch_binary
channel is of type switch_binary
and supports the Switch
item and is in the Switch
category.
Indicates the instantaneous power consumption.
The meter_watts
channel is of type meter_watts
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
Indicates the energy consumption (kWh).
The meter_kwh
channel is of type meter_kwh
and supports the Number
item and is in the Energy
category. This is a read only channel so will only be updated following state changes from the device.
The following table provides a summary of the 1 configuration parameters available in the PSC132ZW. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
31 | Local Control Off | Separates pushbutton and S1 input from relay |
Separates pushbutton and S1 input from relay If "LocalControlOn" is set (factory default state) the PSC132ZWs output can be switched manually by a mechanical rocker-switch or a pushbutton that is connected to the S1 input of the device. If "LocalControlOff" is set, the PSC132ZWs output can only be switched through Z-Wave telegrams. In both modes the operational state of the mechanical switch is reported to association group 2. LocalControlOff is ment for using the switch-input functionality and the relay functionality separately. The following option values may be configured -:
Value | Description |
---|---|
0 | LocalControlOn |
1 | LocalControlOff |
The manufacturer defined default value is 0
(LocalControlOn).
This parameter has the configuration ID config_31_1_00000001
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The PSC132ZW supports 2 association groups.
Output State and Power Meter Events/Notifications:
- Sends COMMAND_CLASS_BASIC, BASIC_REPORT after every change of the output state (on/off).
- Sends COMMAND_CLASS_METER_V2, METER_REPORT_V2 after every change of the measured energy or power value or after a timeout if the values stay unchanged. during If the energy or power value didn't change for a certain time.
Min. time between 2 reports if the energy or power value changes: 1s
Timeout for sending a report if the value stays unchanged: 15min.
Min. change in value to trigger a report:
4% power (mind. 2W) oder 1Wh energy
Association group 1 supports 5 nodes.
Reports S1 Input State Events/Notifications:
Sends COMMAND_CLASS_BASIC, BASIC_REPORT every time the mechanical switch at the input S1 is operated.
Association group 2 supports 5 nodes.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_METER_V2 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_PROTECTION_V1 | |
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V2 |