ZW96 Smart Plug Outdoor

This describes the Z-Wave device ZW96, manufactured by NIE Technology with the thing type UID of nietech_zw96_00_000.

The device is in the category of Power Outlet, defining Small devices to be plugged into a power socket in a wall which stick there.

ZW96 product image

The ZW96 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

Outdoor Z-Wave Plus On/Off Light and Appliance Plug, 1 On/Off Outlet + 1 Alway On Outlet

  • AC plug
  • Always-On outlet
  • Z-Wave controlled outlet
  • ON/OFF/PROG Push button
  • Status LED   Supported max 15 Amp, 120V AC.
  • IP65 Waterproof Design (don't immerse), ideal outdoor use for garden, washing machine, patio, Christmas tree, landscape lighting, fountains, pumps and other indoor and outdoor plug-in appliances, etc.
  • Operating Temp of -4F to 120F

Inclusion Information

Include ZW96 to/from a Z-Wave Gateway with supporting Security.The ZW96 can support the Primary Controller that implemented the security S2.

Notice: Including a node ID allocated by Z-WaveTM Controller means “Add” or “Inclusion”. Excluding a node ID allocated by

Z-WaveTM Controller means “Remove” or “Exclusion”.

Exclusion Information

Include ZW96 to/from a Z-Wave Gateway with supporting Security.The ZW96 can support the Primary Controller that implemented the security S2.

Notice: Including a node ID allocated by Z-WaveTM Controller means “Add” or “Inclusion”. Excluding a node ID allocated by

Z-WaveTM Controller means “Remove” or “Exclusion”.

General Usage Information

Restoring Factory Defaults

All Configuration Parameters values and Association information will be restored to factory default settings and excluded from the network.

When the device is removed from the host, it is returned to the factory settings

MANUAL RESET

  • Power off ZW96
  • keep holding the PROG button
  • Power on,Press and keep holding the PROG button for no less than 10 seconds.

Remark : All the setting and data will be permanently deleted.

Please use this procedure only when the network primary controller is missing or otherwise inoperable.

Channels

The following table summarises the channels available for the ZW96 -:

Channel Name Channel ID Channel Type Category Item Type
Switch switch_binary switch_binary Switch Switch

Switch

Switch the power on and off.

The switch_binary channel is of type switch_binary and supports the Switch item and is in the Switch category.

Device Configuration

The following table provides a summary of the 2 configuration parameters available in the ZW96. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Status LED Status LED Configuration
2 Count Down Count Down Configuration

Parameter 1: Status LED

Status LED Configuration Status LED Configuration The following option values may be configured -:

Value Description
0 Outlet on, LED On
1 Outlet on, Led Off
2 LED Off, LED No Work

The manufacturer defined default value is 0 (Outlet on, LED On).

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Parameter 2: Count Down

Count Down Configuration

Values in the range 0 to 65535 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_2_2 and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The ZW96 supports 2 association groups.

Group 1: Lifeline

The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. Z-Wave Plus Lifeline

  1. ZW96 will trigger AUTO report function if the Switch status had been changed.
  2. Device Reset Locally Notification(Only report when the ZW96 Switch Module has been triggered the RESET TO DEFAULT)

Association group 1 supports 5 nodes.

Group 2: Basic Set Command

Association group 2 supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_VERSION_V2
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3
COMMAND_CLASS_SECURITY_V1