layout title
documentation
NZW39 - ZWave

{% include base.html %}

NZW39 Dimmable Smart Plug

This describes the Z-Wave device NZW39, manufactured by NIE Technology with the thing type UID of nietech_nzw39_00_000.

The device is in the category of Power Outlet, defining Small devices to be plugged into a power socket in a wall which stick there.

NZW39 product image

The NZW39 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

Z-Wave Plug/Dimmer w/Built-in Z-Wave Repeater, combines a Z-Wave Outlet & Range Extender in 1 Module

Inclusion Information

Put the controller into inclusion mode, then push the middle button on the smart plug 3-5 times within 3 seconds

Exclusion Information

Put the controller into exclusion mode, then push the middle button on the smart plug 3-5 times within 3 seconds

General Usage Information

500W Incandescent (1-Gang), 400W Incandescent (2-Gang), 300W Incandescent (3-Gang)

NOTE: If you’d like to disable the white LED light, after you include it to your network, hold down the Manual Button (A) for 10 seconds (re-enable by holding for 10 seconds).

IMPORTANT: This device defaults back to the state it was in prior to a power outage (ie: if the device was off prior to a power outage, it will remain off when power is restored, and vice versa if the device was on).

Please use your controller to remove the device from your network to factory reset. Only use this if your controller is missing or inoperable.

Channels

The following table summarises the channels available for the NZW39 -:

Channel Name Channel ID Channel Type Category Item Type
Dimmer switch_dimmer switch_dimmer DimmableLight Dimmer

Dimmer

The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.

The switch_dimmer channel is of type switch_dimmer and supports the Dimmer item and is in the DimmableLight category.

Device Configuration

The following table provides a summary of the 12 configuration parameters available in the NZW39. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Dimming Step Percentage of step when switch is dimming up or down (0 = instant)
2 Minimum Level Minimum dimming level for attached light
3 LED Indicator Turn LED indicator ON when light is ON (paddle switch only)
4 Invert Switch Invert on & off on the physical switch
5 Auto OFF Automatically turn switch off after this number of seconds
6 Send command on local action When should the switch send commands to Group 3 devices?
6 Send command on 3-way action When should the switch send commands to Group 3 devices?
6 Send command on z-wave action When should the switch send commands to Group 3 devices?
6 Send command on auto off timer When should the switch send commands to Group 3 devices?
7 Association Group 3 setting Change how devices respond when associated in group 3
8 Default Level (local) Default level when light is turned on at the switch (0 = previous level)
9 Default Level (Z-Wave) Default level when light is turned on via Z-Wave command (0 = previous level)
Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Parameter 1: Dimming Step

Percentage of step when switch is dimming up or down (0 = instant)

Values in the range 0 to 99 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Parameter 2: Minimum Level

Minimum dimming level for attached light

Values in the range 1 to 99 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_2_1 and is of type INTEGER.

Parameter 3: LED Indicator

Turn LED indicator ON when light is ON (paddle switch only)

The following option values may be configured -:

Value Description
0 Off
1 On
2 Disabled
3 Always ON

The manufacturer defined default value is 1 (ON).

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Parameter 4: Invert Switch

Invert on & off on the physical switch

The following option values may be configured -:

Value Description
0 Disable
1 Enable

The manufacturer defined default value is 0 (Disable).

This parameter has the configuration ID config_4_1 and is of type INTEGER.

Parameter 5: Auto OFF

Automatically turn switch off after this number of seconds

Values in the range 0 to 32767 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_5_2 and is of type INTEGER.

Parameter 6: Send command on local action

When should the switch send commands to Group 3 devices?

The following option values may be configured -:

Value Description
0 Disable
1 Enable

The manufacturer defined default value is 1 (Enable).

This parameter has the configuration ID config_6_1_00000001 and is of type INTEGER.

Parameter 6: Send command on 3-way action

When should the switch send commands to Group 3 devices?

The following option values may be configured -:

Value Description
0 Disable
1 Enable

The manufacturer defined default value is 0 (Disable).

This parameter has the configuration ID config_6_1_00000002 and is of type INTEGER.

Parameter 6: Send command on z-wave action

When should the switch send commands to Group 3 devices?

The following option values may be configured -:

Value Description
0 Disable
1 Enable

The manufacturer defined default value is 0 (Disable).

This parameter has the configuration ID config_6_1_00000004 and is of type INTEGER.

Parameter 6: Send command on auto off timer

When should the switch send commands to Group 3 devices?

The following option values may be configured -:

Value Description
0 Disable
8 Enable

The manufacturer defined default value is 0 (Disable).

This parameter has the configuration ID config_6_1_00000008 and is of type INTEGER.

Parameter 7: Association Group 3 setting

Change how devices respond when associated in group 3

The following option values may be configured -:

Value Description
0 Dim up/down
1 Keep in sync

The manufacturer defined default value is 0 (Dim up/down).

This parameter has the configuration ID config_7_1 and is of type INTEGER.

Parameter 8: Default Level (local)

Default level when light is turned on at the switch (0 = previous level)

Values in the range 0 to 99 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_8_1 and is of type INTEGER.

Parameter 9: Default Level (Z-Wave)

Default level when light is turned on via Z-Wave command (0 = previous level)

Values in the range 0 to 99 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_9_1 and is of type INTEGER.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -:

Value Description
0 Exclude from All On and All Off groups
1 Include in All On group
2 Include in All Off group
255 Include in All On and All Off groups

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The NZW39 supports 3 association groups.

Group 1: Lifeline

The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation.

Association group 1 supports 1 node.

Group 2: Group 2

Sends on/off commands to associated devices when switch is pressed (BASIC_SET)

Association group 2 supports 5 nodes.

Group 3: Group 3

Sends dim/brighten commands to associated devices when switch is pressed (SWITCH_MULTILEVEL_SET)

Association group 3 supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_MULTILEVEL_V1
COMMAND_CLASS_SWITCH_ALL_V1
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_VERSION_V2

Documentation Links


Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.