This describes the Z-Wave device NZW30, manufactured by NIE Technology with the thing type UID of nietech_nzw30_00_000
.
The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.
The NZW30 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
Turn ON/OFF manually or remotely via the Z-Wave controller
• Can be Included in multiple Groups and Scenes
• Compatible with all incandescent and CFL/ LED bulbs
• Blue LED indicates switch location in a dark room
• Z-Wave Certified for simple pairing and integrated home automation
• Screw Terminal Installation — requires wiring connections for Line (Hot), Load, Neutral.
- Follow the instructions for your Z-Wave certified controller to include a device to the Z-Wave network.
- Once the controller is ready to include your device, triple press the Up/Down push button to include it in the network.
- Follow the instructions for your Z-Wave certified controller to exclude a device from the Z-Wave network.
- Once the controller is ready to Exclude your device, triple press the Up/Down push button to exclude it from the network.
The following table summarises the channels available for the NZW30 -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Switch | switch_binary | switch_binary | Switch | Switch |
Switch the power on and off.
The switch_binary
channel is of type switch_binary
and supports the Switch
item and is in the Switch
category.
The following table provides a summary of the 3 configuration parameters available in the NZW30. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
3 | ledIndicator | Set the LED light behavior |
4 | invert | Invert on & off on the physical switch |
5 | autoOff | Automatically turn switch off after this number of seconds |
Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands |
Set the LED light behavior This setting controls the operation of the LED indicator light on the bottom of the switch. The options are 0,1,2,3. They are described below.
- 0 (default): Turn LED indicator on when switch is off
- 1: Turn LED indicator on when switch is on
- 2: Indicator LED is always off
- 3: Indicator LED is always on The following option values may be configured -:
Value | Description |
---|---|
0 | Turn LED indicator on when switch is off |
1 | Turn LED indicator on when switch is on |
2 | Indicator LED is always off |
3 | Indicator LED is always on |
The manufacturer defined default value is 0
(Turn LED indicator on when switch is off).
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
Invert on & off on the physical switch Invert what the top and bottom of the switch does. The following option values may be configured -:
Value | Description |
---|---|
0 | No |
1 | Yes |
The manufacturer defined default value is 0
(No).
This parameter has the configuration ID config_4_1
and is of type INTEGER
.
Automatically turn switch off after this number of seconds
Values in the range 0 to 32767 may be set.
The manufacturer defined default value is 0
.
This parameter has the configuration ID config_5_2
and is of type INTEGER
.
Set the mode for the switch when receiving SWITCH ALL commands.
The following option values may be configured -:
Value | Description |
---|---|
0 | Exclude from All On and All Off groups |
1 | Include in All On group |
2 | Include in All Off group |
255 | Include in All On and All Off groups |
This parameter has the configuration ID switchall_mode
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The NZW30 supports 1 association group.
The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. An association command class that allows the device to communicate with other Z-Wave devices directly -- such as sending BASIC REPORT whenever the switch is turned on or off.
Association group 1 supports 5 nodes.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_SWITCH_ALL_V1 | |
COMMAND_CLASS_TRANSPORT_SERVICE_V1 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_SUPERVISION_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V2 | |
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3 |