MP22Z Z-Wave Outdoor Smart Plug

This describes the Z-Wave device MP22Z, manufactured by NIE Technology with the thing type UID of nietech_mp22z_00_000.

The device is in the category of Power Outlet, defining Small devices to be plugged into a power socket in a wall which stick there.

MP22Z product image

The MP22Z supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

Outdoor AC Plug

Key Features:

  • Remote ON/OFF control via the Z-Wave controller
  • Manual ON/OFF control with the front panel push button
  • Support Association Group and Auto Report switch status
  • Over temperature protection
  • Support firmware upgrades via Over-the-air (need Gateways support)

Inclusion Information

Put the Z-wave interface controller into “Add” mode, triple press the Program button (A). It will be included to network.

Exclusion Information

Put the Z-Wave interface controller into "Remove" mode, triple press the Program button (A). It will be excluded to network

General Usage Information

Manual reset: click the button 2 times quickly, and hold for at least 10 seconds.
Host reset: Remove it from the host and the device is factory reset.
Note: This should only be used in the event your network’s primary controller is missing or otherwise inoperable.

Channels

The following table summarises the channels available for the MP22Z -:

Channel Name Channel ID Channel Type Category Item Type
Switch switch_binary switch_binary Switch Switch

Switch

Switch the power on and off.

The switch_binary channel is of type switch_binary and supports the Switch item and is in the Switch category.

Device Configuration

The following table provides a summary of the 4 configuration parameters available in the MP22Z. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 LED Indicator Status LED Configuration
2 Auto Turn-Off Timer The countdown time, the socket closed
4 Auto Turn-On Timer Outlet will turn on after
6 Restores state after power failure Restores state after power failure

Parameter 1: LED Indicator

Status LED Configuration Value: 00(default) outlet on,led on.

Value: 01 outlet on,led off.

Value: 02 led off, led no work. The following option values may be configured -:

Value Description
0 outlet on,led on
1 outlet on,led off
2 led off, led no work

The manufacturer defined default value is 0 (outlet on,led on).

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Parameter 2: Auto Turn-Off Timer

The countdown time, the socket closed Countdown time can be set.

LED flashes two times when the configuration parameter is changed Values in the range 0 to 65535 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_2_4 and is of type INTEGER.

Parameter 4: Auto Turn-On Timer

Outlet will turn on after

Values in the range 0 to 65535 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_4_4 and is of type INTEGER.

Parameter 6: Restores state after power failure

Restores state after power failure Parameter=6,Size=1,Value=0 output off Value=1 output on Value=2 (default) out put the state after power The following option values may be configured -:

Value Description
0 output off
1 output on
2 out put the state after power

The manufacturer defined default value is 2 (out put the state after power).

This parameter has the configuration ID config_6_1 and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The MP22Z supports 2 association groups.

Group 1: Lifeline

The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation. Association group 1 This Device supports Lifeline (association group 1) supporting 1 node for lifeline communication. Group 1 must be assigned the Node ID of the primary controller where unsolicited notifications will be sent. The Z-Wave controller should set this association automatically after inclusion. Lifeline association only supports the “Device Reset Locally” function. Refer to the instructions of your controller for any available details on how this can be set.

Association group 1 supports 1 node.

Group 2: Left outlet send basic set

Support 2 groups, each group max support 2 devices

Association group 2 supports 2 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_VERSION_V2
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3