MH-DT311 - ZWave

{% include base.html %}

MH-DT311 MCOHome Dimmer Switch

This describes the Z-Wave device MH-DT311, manufactured by McoHome Technology Co., Ltd with the thing type UID of mcohome_mhdt311_00_000.

The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.

MH-DT311 product image

The MH-DT311 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

Dimmer Switch is a wall panel built-in with Z-Wave Plus module. With its stylish design and stable performance, the panel can be used to control the light level. It supports basic command class, multi channel command class and multi channel association command class, also works as a repeater in a Z-Wave network. This product can be included and operated in any Z-Wave network with other Z-Wave certified devices from any other manufacturers.

Inclusion Information

Set controller into Add/Remove mode, and press 3 clicks on "+" or "-" button to add/remove. If succeed, green LED flicks 4 times.

Exclusion Information

Set controller into Add/Remove mode, and press 3 clicks on "+" or "-" button to add/remove. If succeed, green LED flicks 4 times.

Channels

The following table summarises the channels available for the MH-DT311 -:

Channel Name Channel ID Channel Type Category Item Type
Binary switch_binary switch_binary Switch Switch
Dimmer switch_dimmer switch_dimmer DimmableLight Dimmer
Scene Number scene_number scene_number Number
Electric meter (kWh) meter_kwh meter_kwh Energy Number
Electric meter (volts) meter_voltage meter_voltage Energy Number
Electric meter (amps) meter_current meter_current Energy Number
Electric meter (watts) meter_watts meter_watts Energy Number
Alarm (power) alarm_power alarm_power Energy Switch

Binary

Switch the power on and off.

The switch_binary channel is of type switch_binary and supports the Switch item and is in the Switch category.

Dimmer

The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.

The switch_dimmer channel is of type switch_dimmer and supports the Dimmer item and is in the DimmableLight category.

Scene Number

Triggers when a scene button is pressed.

The scene_number channel is of type scene_number and supports the Number item.

Electric meter (kWh)

Indicates the energy consumption (kWh).

The meter_kwh channel is of type meter_kwh and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (volts)

Indicates the instantaneous voltage.

The meter_voltage channel is of type meter_voltage and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (amps)

Indicates the instantaneous current consumption.

The meter_current channel is of type meter_current and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (watts)

Indicates the instantaneous power consumption.

The meter_watts channel is of type meter_watts and supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Alarm (power)

Indicates if a power alarm is triggered.

The alarm_power channel is of type alarm_power and supports the Switch item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Device Configuration

The following table provides a summary of the 19 configuration parameters available in the MH-DT311. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Dimmer state saved or not when power down Dimmer state saved or not when power down
2 Dimming mode Dimming mode
3 Auto detection of dimming mode when powered on Auto detection of dimming mode when powered on
4 LED Backlit brightness level LED Backlit brightness level
5 Minimum brightness level
6 Maximum brightness level
7 Single dimming step time (Manual) Single dimming step time (Manual)
8 Single dimming step size (Manual) Single dimming step size (Manual)
9 Single dimming step time (Auto) Single dimming step time (Auto)
10 Single dimming step size (Auto) Single dimming step size (Auto)
11 The dimming percentage single touch The dimming percentage single touch
12 Reporting interval for dimming level Reporting interval for dimming level
13 External switch type External switch type
14 External switch input External switch input
15 Energy meter reporting Energy meter reporting
16 Energy meter reporting interval Energy meter reporting interval
17 Beep Beep
32 Ampere alarm threshold Ampere alarm threshold
33 Voltage alarm threshold Voltage alarm threshold

Parameter 1: Dimmer state saved or not when power down

Dimmer state saved or not when power down 0 - Dimmer will be off when powered again

1 - Dimmer will keep the same state when powered again Values in the range 0 to 1 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Parameter 2: Dimming mode

Dimming mode 0 - leading edge

1 - trailing edge 

2 - On/off only Values in the range 0 to 2 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_2_1 and is of type INTEGER.

Parameter 3: Auto detection of dimming mode when powered on

Auto detection of dimming mode when powered on 0 - Auto detection disabled

1 - Auto detection enabled Values in the range 0 to 1 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Parameter 4: LED Backlit brightness level

LED Backlit brightness level 0 - LED disabled 

1-10 Min level-Max level Values in the range 0 to 10 may be set.

The manufacturer defined default value is 10.

This parameter has the configuration ID config_4_1 and is of type INTEGER.

Parameter 5: Minimum brightness level

Values in the range 1 to 98 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_5_1 and is of type INTEGER.

Parameter 6: Maximum brightness level

Values in the range 2 to 99 may be set.

The manufacturer defined default value is 63.

This parameter has the configuration ID config_6_1 and is of type INTEGER.

Parameter 7: Single dimming step time (Manual)

Single dimming step time (Manual)

Values in the range 0 to 2550 may be set.

The manufacturer defined default value is 30.

This parameter has the configuration ID config_7_2 and is of type INTEGER.

Parameter 8: Single dimming step size (Manual)

Single dimming step size (Manual)

Values in the range 1 to 99 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_8_1 and is of type INTEGER.

Parameter 9: Single dimming step time (Auto)

Single dimming step time (Auto)

Values in the range 0 to 2550 may be set.

The manufacturer defined default value is 30.

This parameter has the configuration ID config_9_2 and is of type INTEGER.

Parameter 10: Single dimming step size (Auto)

Single dimming step size (Auto)

Values in the range 0 to 99 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_10_1 and is of type INTEGER.

Parameter 11: The dimming percentage single touch

The dimming percentage single touch

Values in the range 0 to 99 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_11_1 and is of type INTEGER.

Parameter 12: Reporting interval for dimming level

Reporting interval for dimming level

Values in the range 0 to 255 may be set.

The manufacturer defined default value is 10.

This parameter has the configuration ID config_12_1 and is of type INTEGER.

Parameter 13: External switch type

External switch type

Values in the range 0 to 1 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_13_1 and is of type INTEGER.

Parameter 14: External switch input

External switch input

Values in the range 0 to 4 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_14_1 and is of type INTEGER.

Parameter 15: Energy meter reporting

Energy meter reporting

Values in the range 0 to 15 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_15_1 and is of type INTEGER.

Parameter 16: Energy meter reporting interval

Energy meter reporting interval

Values in the range 0 to 255 may be set.

The manufacturer defined default value is 16.

This parameter has the configuration ID config_16_1 and is of type INTEGER.

Parameter 17: Beep

Beep

Values in the range 0 to 1 may be set.

The manufacturer defined default value is 1.

This parameter has the configuration ID config_17_1 and is of type INTEGER.

Parameter 32: Ampere alarm threshold

Ampere alarm threshold

Values in the range 0 to 20480 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_32_2 and is of type INTEGER.

Parameter 33: Voltage alarm threshold

Voltage alarm threshold

Values in the range 0 to 65535 may be set.

The manufacturer defined default value is 0.

This parameter has the configuration ID config_33_2 and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The MH-DT311 supports 4 association groups.

Group 1: Lifeline

The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation.

Association group 1 supports 1 node.

Group 2: Associate with the panel

Association group 2 supports 5 nodes.

Group 5: Associate with Key “+”

Association group 5 supports 5 nodes.

Group 8: Associate with Key “-”

Association group 8 supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_MULTILEVEL_V2
COMMAND_CLASS_SCENE_ACTIVATION_V1
COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1
COMMAND_CLASS_METER_V3
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_ALARM_V4
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_VERSION_V2

Documentation Links