{% include base.html %}

WS15Z-1 Wall Mounted Switch

This describes the Z-Wave device WS15Z-1, manufactured by Linear Corp with the thing type UID of linear_ws15z_00_000.

The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.

WS15Z-1 product image

The WS15Z-1 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

Scene and NWI capable wall mounted switch

Inclusion Information

  1. With your Controller in Discovery or Add Mode, tap the switch once for Network Wide Inclusion. Tap twice for Standard Inclusion.
  2. You should see an indication on your Controller that the “device was added” to the network and the LED will stop blinking.

Exclusion Information

  1. Set the Controller into Removal Mode and follow its instruction to delete the WS15Z-1 from the Controller.
  2. Remove the switch by tapping the paddle 2 times.
  3. You should see an indication on your Controller that the “device was removed” from the network.

Channels

The following table summarises the channels available for the WS15Z-1 -:

Channel Name Channel ID Channel Type Category Item Type
Switch switch_binary switch_binary Switch Switch
Dimmer switch_dimmer switch_dimmer DimmableLight Dimmer
Scene Number scene_number scene_number Number
Battery Level battery-level system.battery_level Battery Number

Switch

Switch the power on and off.

The switch_binary channel is of type switch_binary and supports the Switch item and is in the Switch category.

Dimmer

The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.

The switch_dimmer channel is of type switch_dimmer and supports the Dimmer item and is in the DimmableLight category.

Scene Number

Triggers when a scene button is pressed.

The scene_number channel is of type scene_number and supports the Number item.

Battery Level

Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.

The system.battery-level channel is of type system.battery-level and supports the Number item and is in the Battery category. This channel provides the battery level as a percentage and also reflects the low battery warning state. If the battery state is in low battery warning state, this will read 0%.

Device Configuration

The following table provides a summary of the 2 configuration parameters available in the WS15Z-1. Detailed information on each parameter can be found in the sections below.

Param Name Description
3 Night Light By default, the LED will turn OFF when the lead attached is turned ON.
4 Invert Switch To change the top of the switch to OFF and the bottom of the switch ON.
Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Parameter 3: Night Light

By default, the LED will turn OFF when the lead attached is turned ON.

The following option values may be configured -:

Value Description
0 On when load is on
1 Off when load is on

The manufacturer defined default value is 1 (Off when load is on).

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Parameter 4: Invert Switch

To change the top of the switch to OFF and the bottom of the switch ON.

The following option values may be configured -:

Value Description
0 Top-ON, Bottom-OFF
1 Bottom-ON, Top-OFF

The manufacturer defined default value is 0 (Top-ON, Bottom-OFF ).

This parameter has the configuration ID config_4_1 and is of type INTEGER.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -:

Value Description
0 Exclude from All On and All Off groups
1 Include in All On group
2 Include in All Off group
255 Include in All On and All Off groups

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The device does not support associations.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_APPLICATION_STATUS_V1
COMMAND_CLASS_SWITCH_BINARY_V1
COMMAND_CLASS_SWITCH_MULTILEVEL_V1 Linked to BASIC
COMMAND_CLASS_SWITCH_ALL_V1
COMMAND_CLASS_SCENE_ACTIVATION_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_BATTERY_V1
COMMAND_CLASS_VERSION_V1