layout | title |
---|---|
documentation |
WO15Z - ZWave |
{% include base.html %}
This describes the Z-Wave device WO15Z, manufactured by Linear Corp with the thing type UID of linear_wo15z_00_000
.
The device is in the category of Power Outlet, defining Small devices to be plugged into a power socket in a wall which stick there.
The WO15Z supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
120 VAC 15 Amp Duplex Receptacle
- Prepare the Controller to include a unit to the network. The WO15Z-1 must be in its permanently installed location.
- Press the button on the WO15Z-1 once.
- You should see an indication on your Controller that the “DEVICE WAS INCLUDED” in the network.
- Set the Controller into Removal Mode and follow its instruction to delete the
WO15Z-1 from the Controller. - Remove the switch by pressing the button twice.
- You should see an indication on your Controller that the “device was removed” from the network.
The following table summarises the channels available for the WO15Z -:
Channel Name | Channel ID | Channel Type | Category | Item Type |
---|---|---|---|---|
Switch | switch_binary | switch_binary | Switch | Switch |
Scene Number | scene_number | scene_number | Number |
Switch the power on and off.
The switch_binary
channel is of type switch_binary
and supports the Switch
item and is in the Switch
category.
Triggers when a scene button is pressed.
The scene_number
channel is of type scene_number
and supports the Number
item.
The following table provides a summary of the 1 configuration parameters available in the WO15Z. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
3 | Night Light | LED mode for attached load |
Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands |
LED mode for attached load By default, the blue LED on the WO15Z-1 will turn ON when the load attached is turned ON. To make the LED turn OFF when the load attached is turned ON, set Parameter 3 to a value of 1. The following option values may be configured -:
Value | Description |
---|---|
0 | On when load is on |
1 | Off when load is on |
The manufacturer defined default value is 0
(On when load is on).
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
Set the mode for the switch when receiving SWITCH ALL commands.
The following option values may be configured -:
Value | Description |
---|---|
0 | Exclude from All On and All Off groups |
1 | Include in All On group |
2 | Include in All Off group |
255 | Include in All On and All Off groups |
This parameter has the configuration ID switchall_mode
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The device does not support associations.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_SWITCH_ALL_V1 | |
COMMAND_CLASS_SCENE_ACTIVATION_V1 | |
COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_PROTECTION_V1 | |
COMMAND_CLASS_VERSION_V1 |
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.